Development of a Robust, Simple, and Affordable Human Gait Analysis System Using Bottom-Up Pose Estimation With a Smartphone Camera

Gait analysis is used in many fields such as Medical Diagnostics, Osteopathic medicine, Comparative and Sports-related biomechanics, etc. The most commonly used system for capturing gait is the advanced video camera-based passive marker system such as VICON. However, such systems are expensive, and...

Descripción completa

Detalles Bibliográficos
Autores principales: Viswakumar, Aditya, Rajagopalan, Venkateswaran, Ray, Tathagata, Gottipati, Pranitha, Parimi, Chandu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8766671/
https://www.ncbi.nlm.nih.gov/pubmed/35069246
http://dx.doi.org/10.3389/fphys.2021.784865
_version_ 1784634580131643392
author Viswakumar, Aditya
Rajagopalan, Venkateswaran
Ray, Tathagata
Gottipati, Pranitha
Parimi, Chandu
author_facet Viswakumar, Aditya
Rajagopalan, Venkateswaran
Ray, Tathagata
Gottipati, Pranitha
Parimi, Chandu
author_sort Viswakumar, Aditya
collection PubMed
description Gait analysis is used in many fields such as Medical Diagnostics, Osteopathic medicine, Comparative and Sports-related biomechanics, etc. The most commonly used system for capturing gait is the advanced video camera-based passive marker system such as VICON. However, such systems are expensive, and reflective markers on subjects can be intrusive and time-consuming. Moreover, the setup of markers for certain rehabilitation patients, such as people with stroke or spinal cord injuries, could be difficult. Recently, some markerless systems were introduced to overcome the challenges of marker-based systems. However, current markerless systems have low accuracy and pose other challenges in gait analysis with people in long clothing, hiding the gait kinematics. The present work attempts to make an affordable, easy-to-use, accurate gait analysis system while addressing all the mentioned issues. The system in this study uses images from a video taken with a smartphone camera (800 × 600 pixels at an average rate of 30 frames per second). The system uses OpenPose, a 2D real-time multi-person keypoint detection technique. The system learns to associate body parts with individuals in the image using Convolutional Neural Networks (CNNs). This bottom-up system achieves high accuracy and real-time performance, regardless of the number of people in the image. The proposed system is called the “OpenPose based Markerless Gait Analysis System” (OMGait). Ankle, knee, and hip flexion/extension angle values were measured using OMGait in 16 healthy volunteers under different lighting and clothing conditions. The measured kinematic values were compared with a standard video camera based normative dataset and data from a markerless MS Kinect system. The mean absolute error value of the joint angles from the proposed system was less than 9(0) for different lighting conditions and less than 11(0) for different clothing conditions compared to the normative dataset. The proposed system is adequate in measuring the kinematic values of the ankle, knee, and hip. It also performs better than the markerless systems like MS Kinect that fail to measure the kinematics of ankle, knee, and hip joints under dark and bright light conditions and in subjects with long robe clothing.
format Online
Article
Text
id pubmed-8766671
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-87666712022-01-20 Development of a Robust, Simple, and Affordable Human Gait Analysis System Using Bottom-Up Pose Estimation With a Smartphone Camera Viswakumar, Aditya Rajagopalan, Venkateswaran Ray, Tathagata Gottipati, Pranitha Parimi, Chandu Front Physiol Physiology Gait analysis is used in many fields such as Medical Diagnostics, Osteopathic medicine, Comparative and Sports-related biomechanics, etc. The most commonly used system for capturing gait is the advanced video camera-based passive marker system such as VICON. However, such systems are expensive, and reflective markers on subjects can be intrusive and time-consuming. Moreover, the setup of markers for certain rehabilitation patients, such as people with stroke or spinal cord injuries, could be difficult. Recently, some markerless systems were introduced to overcome the challenges of marker-based systems. However, current markerless systems have low accuracy and pose other challenges in gait analysis with people in long clothing, hiding the gait kinematics. The present work attempts to make an affordable, easy-to-use, accurate gait analysis system while addressing all the mentioned issues. The system in this study uses images from a video taken with a smartphone camera (800 × 600 pixels at an average rate of 30 frames per second). The system uses OpenPose, a 2D real-time multi-person keypoint detection technique. The system learns to associate body parts with individuals in the image using Convolutional Neural Networks (CNNs). This bottom-up system achieves high accuracy and real-time performance, regardless of the number of people in the image. The proposed system is called the “OpenPose based Markerless Gait Analysis System” (OMGait). Ankle, knee, and hip flexion/extension angle values were measured using OMGait in 16 healthy volunteers under different lighting and clothing conditions. The measured kinematic values were compared with a standard video camera based normative dataset and data from a markerless MS Kinect system. The mean absolute error value of the joint angles from the proposed system was less than 9(0) for different lighting conditions and less than 11(0) for different clothing conditions compared to the normative dataset. The proposed system is adequate in measuring the kinematic values of the ankle, knee, and hip. It also performs better than the markerless systems like MS Kinect that fail to measure the kinematics of ankle, knee, and hip joints under dark and bright light conditions and in subjects with long robe clothing. Frontiers Media S.A. 2022-01-05 /pmc/articles/PMC8766671/ /pubmed/35069246 http://dx.doi.org/10.3389/fphys.2021.784865 Text en Copyright © 2022 Viswakumar, Rajagopalan, Ray, Gottipati and Parimi. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Physiology
Viswakumar, Aditya
Rajagopalan, Venkateswaran
Ray, Tathagata
Gottipati, Pranitha
Parimi, Chandu
Development of a Robust, Simple, and Affordable Human Gait Analysis System Using Bottom-Up Pose Estimation With a Smartphone Camera
title Development of a Robust, Simple, and Affordable Human Gait Analysis System Using Bottom-Up Pose Estimation With a Smartphone Camera
title_full Development of a Robust, Simple, and Affordable Human Gait Analysis System Using Bottom-Up Pose Estimation With a Smartphone Camera
title_fullStr Development of a Robust, Simple, and Affordable Human Gait Analysis System Using Bottom-Up Pose Estimation With a Smartphone Camera
title_full_unstemmed Development of a Robust, Simple, and Affordable Human Gait Analysis System Using Bottom-Up Pose Estimation With a Smartphone Camera
title_short Development of a Robust, Simple, and Affordable Human Gait Analysis System Using Bottom-Up Pose Estimation With a Smartphone Camera
title_sort development of a robust, simple, and affordable human gait analysis system using bottom-up pose estimation with a smartphone camera
topic Physiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8766671/
https://www.ncbi.nlm.nih.gov/pubmed/35069246
http://dx.doi.org/10.3389/fphys.2021.784865
work_keys_str_mv AT viswakumaraditya developmentofarobustsimpleandaffordablehumangaitanalysissystemusingbottomupposeestimationwithasmartphonecamera
AT rajagopalanvenkateswaran developmentofarobustsimpleandaffordablehumangaitanalysissystemusingbottomupposeestimationwithasmartphonecamera
AT raytathagata developmentofarobustsimpleandaffordablehumangaitanalysissystemusingbottomupposeestimationwithasmartphonecamera
AT gottipatipranitha developmentofarobustsimpleandaffordablehumangaitanalysissystemusingbottomupposeestimationwithasmartphonecamera
AT parimichandu developmentofarobustsimpleandaffordablehumangaitanalysissystemusingbottomupposeestimationwithasmartphonecamera