Evaluation of Analytical Performances of Magnetic Force-Assisted Electrochemical Sandwich Immunoassay for the Quantification of Carcinoembryonic Antigen

Carcinoembryonic antigen (CEA) is a biomarker indicated in different cancers, targeted for quantitative analysis via immunoassay. Here we introduce a new technique called magnetic force-assisted electrochemical sandwich immunoassay (MESIA) for determination of CEA level in a drop of human serum usin...

Descripción completa

Detalles Bibliográficos
Autores principales: Hwang, Boo Young, Kim, Eunsoo, Kim, Seung-ha, Hwang, Hyundoo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8767762/
https://www.ncbi.nlm.nih.gov/pubmed/35071206
http://dx.doi.org/10.3389/fbioe.2021.798079
_version_ 1784634801175658496
author Hwang, Boo Young
Kim, Eunsoo
Kim, Seung-ha
Hwang, Hyundoo
author_facet Hwang, Boo Young
Kim, Eunsoo
Kim, Seung-ha
Hwang, Hyundoo
author_sort Hwang, Boo Young
collection PubMed
description Carcinoembryonic antigen (CEA) is a biomarker indicated in different cancers, targeted for quantitative analysis via immunoassay. Here we introduce a new technique called magnetic force-assisted electrochemical sandwich immunoassay (MESIA) for determination of CEA level in a drop of human serum using a fully automated point-of-care testing (POCT) device. The analytical performances of the assay are assessed based on precision, accuracy, limit of blank (LoB), limit of detection (LoD) and limit of quantitation (LoQ), linearity, Hook effect, interference, cross-reactivity, and method comparison following the guidelines of the Clinical Laboratory Standards Institute (CLSI). The LoD is 0.50 ng/ml. A linear relationship is shown in the range of 0.5–200 ng/ml. A high dose effect is not seen up to approximately 500,000 ng/ml. The recovery range is from 94.7 to 108.9%. The %CV of run-to-run and within-lab variations are less than 2.04 and 4.41% across the CEA concentrations, respectively, whereas reproducibility is 4.45–6.24%. Method comparison shows that the assay correlates well with the reference device (R ( 2 ) = 0.9884). The assay demonstrates acceptable precision, accuracy, LoB, LoD and LoQ, hook effect, linearity, interference, cross-reactivity, and high correlation with its reference device. Thus, the system is suitable for the quantification of CEA in clinical practices with a POCT manner.
format Online
Article
Text
id pubmed-8767762
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-87677622022-01-20 Evaluation of Analytical Performances of Magnetic Force-Assisted Electrochemical Sandwich Immunoassay for the Quantification of Carcinoembryonic Antigen Hwang, Boo Young Kim, Eunsoo Kim, Seung-ha Hwang, Hyundoo Front Bioeng Biotechnol Bioengineering and Biotechnology Carcinoembryonic antigen (CEA) is a biomarker indicated in different cancers, targeted for quantitative analysis via immunoassay. Here we introduce a new technique called magnetic force-assisted electrochemical sandwich immunoassay (MESIA) for determination of CEA level in a drop of human serum using a fully automated point-of-care testing (POCT) device. The analytical performances of the assay are assessed based on precision, accuracy, limit of blank (LoB), limit of detection (LoD) and limit of quantitation (LoQ), linearity, Hook effect, interference, cross-reactivity, and method comparison following the guidelines of the Clinical Laboratory Standards Institute (CLSI). The LoD is 0.50 ng/ml. A linear relationship is shown in the range of 0.5–200 ng/ml. A high dose effect is not seen up to approximately 500,000 ng/ml. The recovery range is from 94.7 to 108.9%. The %CV of run-to-run and within-lab variations are less than 2.04 and 4.41% across the CEA concentrations, respectively, whereas reproducibility is 4.45–6.24%. Method comparison shows that the assay correlates well with the reference device (R ( 2 ) = 0.9884). The assay demonstrates acceptable precision, accuracy, LoB, LoD and LoQ, hook effect, linearity, interference, cross-reactivity, and high correlation with its reference device. Thus, the system is suitable for the quantification of CEA in clinical practices with a POCT manner. Frontiers Media S.A. 2022-01-03 /pmc/articles/PMC8767762/ /pubmed/35071206 http://dx.doi.org/10.3389/fbioe.2021.798079 Text en Copyright © 2022 Hwang, Kim, Kim and Hwang. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Bioengineering and Biotechnology
Hwang, Boo Young
Kim, Eunsoo
Kim, Seung-ha
Hwang, Hyundoo
Evaluation of Analytical Performances of Magnetic Force-Assisted Electrochemical Sandwich Immunoassay for the Quantification of Carcinoembryonic Antigen
title Evaluation of Analytical Performances of Magnetic Force-Assisted Electrochemical Sandwich Immunoassay for the Quantification of Carcinoembryonic Antigen
title_full Evaluation of Analytical Performances of Magnetic Force-Assisted Electrochemical Sandwich Immunoassay for the Quantification of Carcinoembryonic Antigen
title_fullStr Evaluation of Analytical Performances of Magnetic Force-Assisted Electrochemical Sandwich Immunoassay for the Quantification of Carcinoembryonic Antigen
title_full_unstemmed Evaluation of Analytical Performances of Magnetic Force-Assisted Electrochemical Sandwich Immunoassay for the Quantification of Carcinoembryonic Antigen
title_short Evaluation of Analytical Performances of Magnetic Force-Assisted Electrochemical Sandwich Immunoassay for the Quantification of Carcinoembryonic Antigen
title_sort evaluation of analytical performances of magnetic force-assisted electrochemical sandwich immunoassay for the quantification of carcinoembryonic antigen
topic Bioengineering and Biotechnology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8767762/
https://www.ncbi.nlm.nih.gov/pubmed/35071206
http://dx.doi.org/10.3389/fbioe.2021.798079
work_keys_str_mv AT hwangbooyoung evaluationofanalyticalperformancesofmagneticforceassistedelectrochemicalsandwichimmunoassayforthequantificationofcarcinoembryonicantigen
AT kimeunsoo evaluationofanalyticalperformancesofmagneticforceassistedelectrochemicalsandwichimmunoassayforthequantificationofcarcinoembryonicantigen
AT kimseungha evaluationofanalyticalperformancesofmagneticforceassistedelectrochemicalsandwichimmunoassayforthequantificationofcarcinoembryonicantigen
AT hwanghyundoo evaluationofanalyticalperformancesofmagneticforceassistedelectrochemicalsandwichimmunoassayforthequantificationofcarcinoembryonicantigen