Cargando…

Performance of Three Tests for SARS-CoV-2 on a University Campus Estimated Jointly with Bayesian Latent Class Modeling

Accurate tests for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) have been critical in efforts to control its spread. The accuracy of tests for SARS-CoV-2 has been assessed numerous times, usually in reference to a gold standard diagnosis. One major disadvantage of that approach is th...

Descripción completa

Detalles Bibliográficos
Autores principales: Perkins, T. Alex, Stephens, Melissa, Alvarez Barrios, Wendy, Cavany, Sean, Rulli, Liz, Pfrender, Michael E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Society for Microbiology 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8768831/
https://www.ncbi.nlm.nih.gov/pubmed/35044220
http://dx.doi.org/10.1128/spectrum.01220-21
_version_ 1784635006380933120
author Perkins, T. Alex
Stephens, Melissa
Alvarez Barrios, Wendy
Cavany, Sean
Rulli, Liz
Pfrender, Michael E.
author_facet Perkins, T. Alex
Stephens, Melissa
Alvarez Barrios, Wendy
Cavany, Sean
Rulli, Liz
Pfrender, Michael E.
author_sort Perkins, T. Alex
collection PubMed
description Accurate tests for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) have been critical in efforts to control its spread. The accuracy of tests for SARS-CoV-2 has been assessed numerous times, usually in reference to a gold standard diagnosis. One major disadvantage of that approach is the possibility of error due to inaccuracy of the gold standard, which is especially problematic for evaluating testing in a real-world surveillance context. We used an alternative approach known as Bayesian latent class modeling (BLCM), which circumvents the need to designate a gold standard by simultaneously estimating the accuracy of multiple tests. We applied this technique to a collection of 1,716 tests of three types applied to 853 individuals on a university campus during a 1-week period in October 2020. We found that reverse transcriptase PCR (RT-PCR) testing of saliva samples performed at a campus facility had higher sensitivity (median, 92.3%; 95% credible interval [CrI], 73.2 to 99.6%) than RT-PCR testing of nasal samples performed at a commercial facility (median, 85.9%; 95% CrI, 54.7 to 99.4%). The reverse was true for specificity, although the specificity of saliva testing was still very high (median, 99.3%; 95% CrI, 98.3 to 99.9%). An antigen test was less sensitive and specific than both of the RT-PCR tests, although the sample sizes with this test were small and the statistical uncertainty was high. These results suggest that RT-PCR testing of saliva samples at a campus facility can be an effective basis for surveillance screening to prevent SARS-CoV-2 transmission in a university setting. IMPORTANCE Testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has been vitally important during the COVID-19 pandemic. There are a variety of methods for testing for this virus, and it is important to understand their accuracy in choosing which one might be best suited for a given application. To estimate the accuracy of three different testing methods, we used a data set collected at a university that involved testing the same samples with multiple tests. Unlike most other estimates of test accuracy, we did not assume that one test was perfect but instead allowed for some degree of inaccuracy in all testing methods. We found that molecular tests performed on saliva samples at a university facility were similarly accurate as molecular tests performed on nasal samples at a commercial facility. An antigen test appeared somewhat less accurate than the molecular tests, but there was high uncertainty about that.
format Online
Article
Text
id pubmed-8768831
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher American Society for Microbiology
record_format MEDLINE/PubMed
spelling pubmed-87688312022-01-24 Performance of Three Tests for SARS-CoV-2 on a University Campus Estimated Jointly with Bayesian Latent Class Modeling Perkins, T. Alex Stephens, Melissa Alvarez Barrios, Wendy Cavany, Sean Rulli, Liz Pfrender, Michael E. Microbiol Spectr Research Article Accurate tests for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) have been critical in efforts to control its spread. The accuracy of tests for SARS-CoV-2 has been assessed numerous times, usually in reference to a gold standard diagnosis. One major disadvantage of that approach is the possibility of error due to inaccuracy of the gold standard, which is especially problematic for evaluating testing in a real-world surveillance context. We used an alternative approach known as Bayesian latent class modeling (BLCM), which circumvents the need to designate a gold standard by simultaneously estimating the accuracy of multiple tests. We applied this technique to a collection of 1,716 tests of three types applied to 853 individuals on a university campus during a 1-week period in October 2020. We found that reverse transcriptase PCR (RT-PCR) testing of saliva samples performed at a campus facility had higher sensitivity (median, 92.3%; 95% credible interval [CrI], 73.2 to 99.6%) than RT-PCR testing of nasal samples performed at a commercial facility (median, 85.9%; 95% CrI, 54.7 to 99.4%). The reverse was true for specificity, although the specificity of saliva testing was still very high (median, 99.3%; 95% CrI, 98.3 to 99.9%). An antigen test was less sensitive and specific than both of the RT-PCR tests, although the sample sizes with this test were small and the statistical uncertainty was high. These results suggest that RT-PCR testing of saliva samples at a campus facility can be an effective basis for surveillance screening to prevent SARS-CoV-2 transmission in a university setting. IMPORTANCE Testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has been vitally important during the COVID-19 pandemic. There are a variety of methods for testing for this virus, and it is important to understand their accuracy in choosing which one might be best suited for a given application. To estimate the accuracy of three different testing methods, we used a data set collected at a university that involved testing the same samples with multiple tests. Unlike most other estimates of test accuracy, we did not assume that one test was perfect but instead allowed for some degree of inaccuracy in all testing methods. We found that molecular tests performed on saliva samples at a university facility were similarly accurate as molecular tests performed on nasal samples at a commercial facility. An antigen test appeared somewhat less accurate than the molecular tests, but there was high uncertainty about that. American Society for Microbiology 2022-01-19 /pmc/articles/PMC8768831/ /pubmed/35044220 http://dx.doi.org/10.1128/spectrum.01220-21 Text en Copyright © 2022 Perkins et al. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution 4.0 International license (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Research Article
Perkins, T. Alex
Stephens, Melissa
Alvarez Barrios, Wendy
Cavany, Sean
Rulli, Liz
Pfrender, Michael E.
Performance of Three Tests for SARS-CoV-2 on a University Campus Estimated Jointly with Bayesian Latent Class Modeling
title Performance of Three Tests for SARS-CoV-2 on a University Campus Estimated Jointly with Bayesian Latent Class Modeling
title_full Performance of Three Tests for SARS-CoV-2 on a University Campus Estimated Jointly with Bayesian Latent Class Modeling
title_fullStr Performance of Three Tests for SARS-CoV-2 on a University Campus Estimated Jointly with Bayesian Latent Class Modeling
title_full_unstemmed Performance of Three Tests for SARS-CoV-2 on a University Campus Estimated Jointly with Bayesian Latent Class Modeling
title_short Performance of Three Tests for SARS-CoV-2 on a University Campus Estimated Jointly with Bayesian Latent Class Modeling
title_sort performance of three tests for sars-cov-2 on a university campus estimated jointly with bayesian latent class modeling
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8768831/
https://www.ncbi.nlm.nih.gov/pubmed/35044220
http://dx.doi.org/10.1128/spectrum.01220-21
work_keys_str_mv AT perkinstalex performanceofthreetestsforsarscov2onauniversitycampusestimatedjointlywithbayesianlatentclassmodeling
AT stephensmelissa performanceofthreetestsforsarscov2onauniversitycampusestimatedjointlywithbayesianlatentclassmodeling
AT alvarezbarrioswendy performanceofthreetestsforsarscov2onauniversitycampusestimatedjointlywithbayesianlatentclassmodeling
AT cavanysean performanceofthreetestsforsarscov2onauniversitycampusestimatedjointlywithbayesianlatentclassmodeling
AT rulliliz performanceofthreetestsforsarscov2onauniversitycampusestimatedjointlywithbayesianlatentclassmodeling
AT pfrendermichaele performanceofthreetestsforsarscov2onauniversitycampusestimatedjointlywithbayesianlatentclassmodeling