Cargando…
Evaluation of Diagnostic Accuracy of Eight Commercial Assays for the Detection of Rubella Virus-Specific IgM Antibodies
Rubella and congenital rubella syndrome are caused by the rubella virus and are preventable through vaccination, making disease eradication possible. Monitoring of progress toward global eradication and local elimination requires high-quality, sensitive disease surveillance that includes laboratory...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Society for Microbiology
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8769748/ https://www.ncbi.nlm.nih.gov/pubmed/34705533 http://dx.doi.org/10.1128/JCM.01597-21 |
Sumario: | Rubella and congenital rubella syndrome are caused by the rubella virus and are preventable through vaccination, making disease eradication possible. Monitoring of progress toward global eradication and local elimination requires high-quality, sensitive disease surveillance that includes laboratory confirmation of cases. Previous evaluations of anti-rubella IgM detection methods resulted in the broad adoption of the Enzygnost (most recently manufactured by Siemens) enzyme-linked immunosorbent assay (ELISA) kits within WHO’s global measles and rubella laboratory network, but they have been discontinued. This study evaluated seven comparable ELISAs from six manufacturers (Trinity Biotech, Euroimmun, Clin-Tech, NovaTec and Virion\Serion) as well as one automated chemiluminescent assay (CLIA) from DiaSorin. These assays include three IgM capture assays and five indirect ELISAs. A panel of 238 sera was used for the evaluation that included 38 archival rubella IgM-positive sera and 200 sera collected from patients with symptomatically similar diseases, such as measles, dengue, parvovirus B19 infection, and roseola. With this panel of sera, the sensitivity of the methods ranged from 63.2% to 100% and the specificity from 80.0% to 99.5%. No single method had both sensitivity and specificity of >90%, unless sera with equivocal results were considered presumptively positive. Some assays, particularly the Serion ELISA, had a large number of false positives with parvovirus B19 IgM-positive sera as well as sera from confirmed measles cases. The performance characteristics identified in this evaluation serve as a reminder to not rely solely on rubella IgM results for case confirmation in elimination settings. |
---|