Occupational fibrotic hypersensitivity pneumonia in a halogen dishes manufacturer: A case report

BACKGROUND: Fibrotic hypersensitivity pneumonitis (FHP) is an allergic and diffuse pneumonia caused by repeated inhalation of antigenic substances, and sometimes developed in people working in specific environments. While novel antigens and exposures continued to be described, physicians should main...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Min, Fang, Hao-Hui, Jiang, Zi-Feng, Ye, Wei, Liu, Rong-Yu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Baishideng Publishing Group Inc 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8771394/
https://www.ncbi.nlm.nih.gov/pubmed/35097102
http://dx.doi.org/10.12998/wjcc.v10.i2.741
_version_ 1784635594759995392
author Wang, Min
Fang, Hao-Hui
Jiang, Zi-Feng
Ye, Wei
Liu, Rong-Yu
author_facet Wang, Min
Fang, Hao-Hui
Jiang, Zi-Feng
Ye, Wei
Liu, Rong-Yu
author_sort Wang, Min
collection PubMed
description BACKGROUND: Fibrotic hypersensitivity pneumonitis (FHP) is an allergic and diffuse pneumonia caused by repeated inhalation of antigenic substances, and sometimes developed in people working in specific environments. While novel antigens and exposures continued to be described, physicians should maintain a high suspicion of potential exposures. A detailed assessment of the patient's occupational exposures as well as living environment is necessary and complete allergen avoidance is the first and most important step in the management of FHP once the allergens are determined. CASE SUMMARY: A 35-year-old female was admitted to the hospital with a cough and breathing difficulties for more than one year. She was a nonsmoker and a manufacturer of halogen dishes, which are characteristic Chinese foods, for 15 years without any protection. High resolution computed tomography of the chest demonstrated an interstitial pneumonia pattern. Pulmonary function examination showed restricted ventilation dysfunction and a significant reduction in dispersion ability. Cell differentiation in bronchoalveolar lavage fluid demonstrated lymphocytosis (70.4%) with an increased lymphocyte CD4/CD8 ratio (0.94). Transbronchial lung biopsy combined with lung puncture pathology showed diffuse uniform alveolar interval thickening, chronic inflammatory cell infiltration, a proliferation of tissue in the bronchial wall fiber and alveolar epithelial follicle degeneration, resulting in fibrosis. CONCLUSION: Exposure to spices used for the production of halogen dishes may cause FHP.
format Online
Article
Text
id pubmed-8771394
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Baishideng Publishing Group Inc
record_format MEDLINE/PubMed
spelling pubmed-87713942022-01-28 Occupational fibrotic hypersensitivity pneumonia in a halogen dishes manufacturer: A case report Wang, Min Fang, Hao-Hui Jiang, Zi-Feng Ye, Wei Liu, Rong-Yu World J Clin Cases Case Report BACKGROUND: Fibrotic hypersensitivity pneumonitis (FHP) is an allergic and diffuse pneumonia caused by repeated inhalation of antigenic substances, and sometimes developed in people working in specific environments. While novel antigens and exposures continued to be described, physicians should maintain a high suspicion of potential exposures. A detailed assessment of the patient's occupational exposures as well as living environment is necessary and complete allergen avoidance is the first and most important step in the management of FHP once the allergens are determined. CASE SUMMARY: A 35-year-old female was admitted to the hospital with a cough and breathing difficulties for more than one year. She was a nonsmoker and a manufacturer of halogen dishes, which are characteristic Chinese foods, for 15 years without any protection. High resolution computed tomography of the chest demonstrated an interstitial pneumonia pattern. Pulmonary function examination showed restricted ventilation dysfunction and a significant reduction in dispersion ability. Cell differentiation in bronchoalveolar lavage fluid demonstrated lymphocytosis (70.4%) with an increased lymphocyte CD4/CD8 ratio (0.94). Transbronchial lung biopsy combined with lung puncture pathology showed diffuse uniform alveolar interval thickening, chronic inflammatory cell infiltration, a proliferation of tissue in the bronchial wall fiber and alveolar epithelial follicle degeneration, resulting in fibrosis. CONCLUSION: Exposure to spices used for the production of halogen dishes may cause FHP. Baishideng Publishing Group Inc 2022-01-14 2022-01-14 /pmc/articles/PMC8771394/ /pubmed/35097102 http://dx.doi.org/10.12998/wjcc.v10.i2.741 Text en ©The Author(s) 2022. Published by Baishideng Publishing Group Inc. All rights reserved. https://creativecommons.org/licenses/by-nc/4.0/This article is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution NonCommercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: https://creativecommons.org/Licenses/by-nc/4.0/
spellingShingle Case Report
Wang, Min
Fang, Hao-Hui
Jiang, Zi-Feng
Ye, Wei
Liu, Rong-Yu
Occupational fibrotic hypersensitivity pneumonia in a halogen dishes manufacturer: A case report
title Occupational fibrotic hypersensitivity pneumonia in a halogen dishes manufacturer: A case report
title_full Occupational fibrotic hypersensitivity pneumonia in a halogen dishes manufacturer: A case report
title_fullStr Occupational fibrotic hypersensitivity pneumonia in a halogen dishes manufacturer: A case report
title_full_unstemmed Occupational fibrotic hypersensitivity pneumonia in a halogen dishes manufacturer: A case report
title_short Occupational fibrotic hypersensitivity pneumonia in a halogen dishes manufacturer: A case report
title_sort occupational fibrotic hypersensitivity pneumonia in a halogen dishes manufacturer: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8771394/
https://www.ncbi.nlm.nih.gov/pubmed/35097102
http://dx.doi.org/10.12998/wjcc.v10.i2.741
work_keys_str_mv AT wangmin occupationalfibrotichypersensitivitypneumoniainahalogendishesmanufactureracasereport
AT fanghaohui occupationalfibrotichypersensitivitypneumoniainahalogendishesmanufactureracasereport
AT jiangzifeng occupationalfibrotichypersensitivitypneumoniainahalogendishesmanufactureracasereport
AT yewei occupationalfibrotichypersensitivitypneumoniainahalogendishesmanufactureracasereport
AT liurongyu occupationalfibrotichypersensitivitypneumoniainahalogendishesmanufactureracasereport