Cargando…

Rational Programming of Cas12a for Early-Stage Detection of COVID-19 by Lateral Flow Assay and Portable Real-Time Fluorescence Readout Facilities

Coronavirus disease 2019 (COVID-19) caused by the SARS-CoV-2 virus has led to a global pandemic with a high spread rate and pathogenicity. Thus, with limited testing solutions, it is imperative to develop early-stage diagnostics for rapid and accurate detection of SARS-CoV-2 to contain the rapid tra...

Descripción completa

Detalles Bibliográficos
Autores principales: Yi, Zhijian, de Dieu Habimana, Jean, Mukama, Omar, Li, Zhiyuan, Odiwuor, Nelson, Jing, Hanzhi, Nie, Chengrong, Hu, Mei, Lin, Zuoxian, Wei, Hongping, Zeng, Lingwen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8773725/
https://www.ncbi.nlm.nih.gov/pubmed/35049639
http://dx.doi.org/10.3390/bios12010011
_version_ 1784636165413928960
author Yi, Zhijian
de Dieu Habimana, Jean
Mukama, Omar
Li, Zhiyuan
Odiwuor, Nelson
Jing, Hanzhi
Nie, Chengrong
Hu, Mei
Lin, Zuoxian
Wei, Hongping
Zeng, Lingwen
author_facet Yi, Zhijian
de Dieu Habimana, Jean
Mukama, Omar
Li, Zhiyuan
Odiwuor, Nelson
Jing, Hanzhi
Nie, Chengrong
Hu, Mei
Lin, Zuoxian
Wei, Hongping
Zeng, Lingwen
author_sort Yi, Zhijian
collection PubMed
description Coronavirus disease 2019 (COVID-19) caused by the SARS-CoV-2 virus has led to a global pandemic with a high spread rate and pathogenicity. Thus, with limited testing solutions, it is imperative to develop early-stage diagnostics for rapid and accurate detection of SARS-CoV-2 to contain the rapid transmission of the ongoing COVID-19 pandemic. In this regard, there remains little knowledge about the integration of the CRISPR collateral cleavage mechanism in the lateral flow assay and fluorophotometer. In the current study, we demonstrate a CRISPR/Cas12a-based collateral cleavage method for COVID-19 diagnosis using the Cas12a/crRNA complex for target recognition, reverse transcription loop-mediated isothermal amplification (RT-LAMP) for sensitivity enhancement, and a novel DNA capture probe-based lateral flow strip (LFS) or real-time fluorescence detector as the parallel system readout facility, termed CRICOLAP. Our novel approach uses a customized reporter that hybridizes an optimized complementary capture probe fixed at the test line for naked-eye result readout. The CRICOLAP system achieved ultra-sensitivity of 1 copy/µL in ~32 min by portable real-time fluorescence detection and ~60 min by LFS. Furthermore, CRICOLAP validation using 60 clinical nasopharyngeal samples previously verified with a commercial RT-PCR kit showed 97.5% and 100% sensitivity for S and N genes, respectively, and 100% specificity for both genes of SARS-CoV-2. CRICOLAP advances the CRISPR/Cas12a collateral cleavage result readout in the lateral flow assay and fluorophotometer, and it can be an alternative method for the decentralized field-deployable diagnosis of COVID-19 in remote and limited-resource locations.
format Online
Article
Text
id pubmed-8773725
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-87737252022-01-21 Rational Programming of Cas12a for Early-Stage Detection of COVID-19 by Lateral Flow Assay and Portable Real-Time Fluorescence Readout Facilities Yi, Zhijian de Dieu Habimana, Jean Mukama, Omar Li, Zhiyuan Odiwuor, Nelson Jing, Hanzhi Nie, Chengrong Hu, Mei Lin, Zuoxian Wei, Hongping Zeng, Lingwen Biosensors (Basel) Article Coronavirus disease 2019 (COVID-19) caused by the SARS-CoV-2 virus has led to a global pandemic with a high spread rate and pathogenicity. Thus, with limited testing solutions, it is imperative to develop early-stage diagnostics for rapid and accurate detection of SARS-CoV-2 to contain the rapid transmission of the ongoing COVID-19 pandemic. In this regard, there remains little knowledge about the integration of the CRISPR collateral cleavage mechanism in the lateral flow assay and fluorophotometer. In the current study, we demonstrate a CRISPR/Cas12a-based collateral cleavage method for COVID-19 diagnosis using the Cas12a/crRNA complex for target recognition, reverse transcription loop-mediated isothermal amplification (RT-LAMP) for sensitivity enhancement, and a novel DNA capture probe-based lateral flow strip (LFS) or real-time fluorescence detector as the parallel system readout facility, termed CRICOLAP. Our novel approach uses a customized reporter that hybridizes an optimized complementary capture probe fixed at the test line for naked-eye result readout. The CRICOLAP system achieved ultra-sensitivity of 1 copy/µL in ~32 min by portable real-time fluorescence detection and ~60 min by LFS. Furthermore, CRICOLAP validation using 60 clinical nasopharyngeal samples previously verified with a commercial RT-PCR kit showed 97.5% and 100% sensitivity for S and N genes, respectively, and 100% specificity for both genes of SARS-CoV-2. CRICOLAP advances the CRISPR/Cas12a collateral cleavage result readout in the lateral flow assay and fluorophotometer, and it can be an alternative method for the decentralized field-deployable diagnosis of COVID-19 in remote and limited-resource locations. MDPI 2021-12-26 /pmc/articles/PMC8773725/ /pubmed/35049639 http://dx.doi.org/10.3390/bios12010011 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Yi, Zhijian
de Dieu Habimana, Jean
Mukama, Omar
Li, Zhiyuan
Odiwuor, Nelson
Jing, Hanzhi
Nie, Chengrong
Hu, Mei
Lin, Zuoxian
Wei, Hongping
Zeng, Lingwen
Rational Programming of Cas12a for Early-Stage Detection of COVID-19 by Lateral Flow Assay and Portable Real-Time Fluorescence Readout Facilities
title Rational Programming of Cas12a for Early-Stage Detection of COVID-19 by Lateral Flow Assay and Portable Real-Time Fluorescence Readout Facilities
title_full Rational Programming of Cas12a for Early-Stage Detection of COVID-19 by Lateral Flow Assay and Portable Real-Time Fluorescence Readout Facilities
title_fullStr Rational Programming of Cas12a for Early-Stage Detection of COVID-19 by Lateral Flow Assay and Portable Real-Time Fluorescence Readout Facilities
title_full_unstemmed Rational Programming of Cas12a for Early-Stage Detection of COVID-19 by Lateral Flow Assay and Portable Real-Time Fluorescence Readout Facilities
title_short Rational Programming of Cas12a for Early-Stage Detection of COVID-19 by Lateral Flow Assay and Portable Real-Time Fluorescence Readout Facilities
title_sort rational programming of cas12a for early-stage detection of covid-19 by lateral flow assay and portable real-time fluorescence readout facilities
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8773725/
https://www.ncbi.nlm.nih.gov/pubmed/35049639
http://dx.doi.org/10.3390/bios12010011
work_keys_str_mv AT yizhijian rationalprogrammingofcas12aforearlystagedetectionofcovid19bylateralflowassayandportablerealtimefluorescencereadoutfacilities
AT dedieuhabimanajean rationalprogrammingofcas12aforearlystagedetectionofcovid19bylateralflowassayandportablerealtimefluorescencereadoutfacilities
AT mukamaomar rationalprogrammingofcas12aforearlystagedetectionofcovid19bylateralflowassayandportablerealtimefluorescencereadoutfacilities
AT lizhiyuan rationalprogrammingofcas12aforearlystagedetectionofcovid19bylateralflowassayandportablerealtimefluorescencereadoutfacilities
AT odiwuornelson rationalprogrammingofcas12aforearlystagedetectionofcovid19bylateralflowassayandportablerealtimefluorescencereadoutfacilities
AT jinghanzhi rationalprogrammingofcas12aforearlystagedetectionofcovid19bylateralflowassayandportablerealtimefluorescencereadoutfacilities
AT niechengrong rationalprogrammingofcas12aforearlystagedetectionofcovid19bylateralflowassayandportablerealtimefluorescencereadoutfacilities
AT humei rationalprogrammingofcas12aforearlystagedetectionofcovid19bylateralflowassayandportablerealtimefluorescencereadoutfacilities
AT linzuoxian rationalprogrammingofcas12aforearlystagedetectionofcovid19bylateralflowassayandportablerealtimefluorescencereadoutfacilities
AT weihongping rationalprogrammingofcas12aforearlystagedetectionofcovid19bylateralflowassayandportablerealtimefluorescencereadoutfacilities
AT zenglingwen rationalprogrammingofcas12aforearlystagedetectionofcovid19bylateralflowassayandportablerealtimefluorescencereadoutfacilities