Cargando…
Influence of Framework Material and Posterior Implant Angulation in Full-Arch All-on-4 Implant-Supported Prosthesis Stress Concentration
This study evaluated the influence of distal implants angulation and framework material in the stress concentration of an All-on-4 full-arch prosthesis. A full-arch implant-supported prosthesis 3D model was created with different distal implant angulations and cantilever arms (30° with 10-mm cantile...
Autores principales: | Tribst, João Paulo Mendes, Campanelli de Morais, Dayana, Melo de Matos, Jefferson David, Lopes, Guilherme da Rocha Scalzer, Dal Piva, Amanda Maria de Oliveira, Souto Borges, Alexandre Luiz, Bottino, Marco Antonio, Lanzotti, Antonio, Martorelli, Massimo, Ausiello, Pietro |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8774799/ https://www.ncbi.nlm.nih.gov/pubmed/35049610 http://dx.doi.org/10.3390/dj10010012 |
Ejemplares similares
-
The Influence of Custom-Milled Framework Design for an Implant-Supported Full-Arch Fixed Dental Prosthesis: 3D-FEA Sudy
por: Tribst, João Paulo Mendes, et al.
Publicado: (2020) -
Comparative three-dimensional finite element analysis of implant-supported fixed complete arch mandibular prostheses in two materials
por: Tribst, João Paulo Mendes, et al.
Publicado: (2017) -
Does the prosthesis weight matter? 3D finite element analysis of a fixed implant-supported prosthesis at different weights and implant numbers
por: Tribst, João Paulo Mendes, et al.
Publicado: (2020) -
The importance of correct implants positioning and masticatory
load direction on a fixed prosthesis
por: Tribst, João-Paulo-Mendes, et al.
Publicado: (2018) -
Simulated damage of two implant debridement methods: Nonsurgical approach with Teflon and stainless steel hand scalers
por: Tribst, João Paulo Mendes, et al.
Publicado: (2018)