Cargando…

Development of (222)Rn Emanation Sources with Integrated Quasi 2π Active Monitoring

In this work, a novel approach for the standardization of low-level (222)Rn emanation is presented. The technique is based on the integration of a (222)Rn source, directly, with an α-particle detector, which allows the residual (222)Rn to be continuously monitored. Preparation of the device entails...

Descripción completa

Detalles Bibliográficos
Autores principales: Mertes, Florian, Röttger, Stefan, Röttger, Annette
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8776009/
https://www.ncbi.nlm.nih.gov/pubmed/35055665
http://dx.doi.org/10.3390/ijerph19020840
_version_ 1784636727298621440
author Mertes, Florian
Röttger, Stefan
Röttger, Annette
author_facet Mertes, Florian
Röttger, Stefan
Röttger, Annette
author_sort Mertes, Florian
collection PubMed
description In this work, a novel approach for the standardization of low-level (222)Rn emanation is presented. The technique is based on the integration of a (222)Rn source, directly, with an α-particle detector, which allows the residual (222)Rn to be continuously monitored. Preparation of the device entails thermal physical vapor deposition of (226)RaCl(2) directly onto the surface of a commercially available ion implanted Si-diode detector, resulting in a thin-layer geometry. This enables continuous collection of well resolved α-particle spectra of the nuclei, decaying within the deposited layer, with a detection efficiency of approximately 0.5 in a quasi 2π geometry. The continuously sampled α-particle spectra are used to derive the emanation by statistical inversion. It is possible to achieve this with high temporal resolution due to the small background and the high counting efficiency of the presented technique. The emanation derived in this way exhibits a dependence on the relative humidity of up to 15% in the range from 20% rH to 90% rH. Traceability to the SI is provided by employing defined solid-angle α-particle spectrometry to characterize the counting efficiency of the modified detectors. The presented technique is demonstrated to apply to a range covering the release of at least 1 to 210 (222)Rn atoms per second, and it results in SI-traceable emanation values with a combined standard uncertainty not exceeding 2%. This provides a pathway for the realization of reference atmospheres covering typical environmental (222)Rn levels and thus drastically improves the realization and the dissemination of the derived unit of the activity concentration concerning (222)Rn in air.
format Online
Article
Text
id pubmed-8776009
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-87760092022-01-21 Development of (222)Rn Emanation Sources with Integrated Quasi 2π Active Monitoring Mertes, Florian Röttger, Stefan Röttger, Annette Int J Environ Res Public Health Article In this work, a novel approach for the standardization of low-level (222)Rn emanation is presented. The technique is based on the integration of a (222)Rn source, directly, with an α-particle detector, which allows the residual (222)Rn to be continuously monitored. Preparation of the device entails thermal physical vapor deposition of (226)RaCl(2) directly onto the surface of a commercially available ion implanted Si-diode detector, resulting in a thin-layer geometry. This enables continuous collection of well resolved α-particle spectra of the nuclei, decaying within the deposited layer, with a detection efficiency of approximately 0.5 in a quasi 2π geometry. The continuously sampled α-particle spectra are used to derive the emanation by statistical inversion. It is possible to achieve this with high temporal resolution due to the small background and the high counting efficiency of the presented technique. The emanation derived in this way exhibits a dependence on the relative humidity of up to 15% in the range from 20% rH to 90% rH. Traceability to the SI is provided by employing defined solid-angle α-particle spectrometry to characterize the counting efficiency of the modified detectors. The presented technique is demonstrated to apply to a range covering the release of at least 1 to 210 (222)Rn atoms per second, and it results in SI-traceable emanation values with a combined standard uncertainty not exceeding 2%. This provides a pathway for the realization of reference atmospheres covering typical environmental (222)Rn levels and thus drastically improves the realization and the dissemination of the derived unit of the activity concentration concerning (222)Rn in air. MDPI 2022-01-12 /pmc/articles/PMC8776009/ /pubmed/35055665 http://dx.doi.org/10.3390/ijerph19020840 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Mertes, Florian
Röttger, Stefan
Röttger, Annette
Development of (222)Rn Emanation Sources with Integrated Quasi 2π Active Monitoring
title Development of (222)Rn Emanation Sources with Integrated Quasi 2π Active Monitoring
title_full Development of (222)Rn Emanation Sources with Integrated Quasi 2π Active Monitoring
title_fullStr Development of (222)Rn Emanation Sources with Integrated Quasi 2π Active Monitoring
title_full_unstemmed Development of (222)Rn Emanation Sources with Integrated Quasi 2π Active Monitoring
title_short Development of (222)Rn Emanation Sources with Integrated Quasi 2π Active Monitoring
title_sort development of (222)rn emanation sources with integrated quasi 2π active monitoring
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8776009/
https://www.ncbi.nlm.nih.gov/pubmed/35055665
http://dx.doi.org/10.3390/ijerph19020840
work_keys_str_mv AT mertesflorian developmentof222rnemanationsourceswithintegratedquasi2pactivemonitoring
AT rottgerstefan developmentof222rnemanationsourceswithintegratedquasi2pactivemonitoring
AT rottgerannette developmentof222rnemanationsourceswithintegratedquasi2pactivemonitoring