Cargando…

Study on the established customized limits for the daily quality assurance procedure

Since there are no corresponding specification limits for some new daily quality assurance (QA) items in the TG-142, it is a compromise that the specification limits used in the monthly or annual QA procedures are used for the daily QA procedure in work. But there is no basis for whether this is fea...

Descripción completa

Detalles Bibliográficos
Autores principales: Jin, Xiao-Li, Song, Jian-Bo, Peng, Jin-Xin, Pan, Xiao-Peng, Guo, Rui, Xing, Xiao-Fen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8776697/
https://www.ncbi.nlm.nih.gov/pubmed/34734293
http://dx.doi.org/10.1093/jrr/rrab079
_version_ 1784636887994990592
author Jin, Xiao-Li
Song, Jian-Bo
Peng, Jin-Xin
Pan, Xiao-Peng
Guo, Rui
Xing, Xiao-Fen
author_facet Jin, Xiao-Li
Song, Jian-Bo
Peng, Jin-Xin
Pan, Xiao-Peng
Guo, Rui
Xing, Xiao-Fen
author_sort Jin, Xiao-Li
collection PubMed
description Since there are no corresponding specification limits for some new daily quality assurance (QA) items in the TG-142, it is a compromise that the specification limits used in the monthly or annual QA procedures are used for the daily QA procedure in work. But there is no basis for whether this is feasible. The purpose of this article is to analyze QA results using SPC to determine the tolerance limits at our institution, and to present the usefulness of the analysis method using SPC. The data of three groups daily QA processes performed with Daily QA3 in three years were analyzed using statistical process control (SPC). For calculating capability indices (C(p), C(pk), C(pm) and C(pmk)) of processes, the appropriate number of calculation points was analyzed firstly. Then, in calculating the capability indices for output, limits ±3% of the daily QA in the TG-142 were used as the specification limit, while for flatness and symmetry, an annual QA limits of ±1% was used. For putting forward measures to solve the problem, customized tolerance and action limits were established for each process. And the process control charts calculated using data measured by the five therapists and a medical physicist were compared. At least six to eight weeks of control daily check data points (i.e. 30–40 points) should be used for calculating the individuals and moving range (I-MR) control chart to ensure the stability of control lines. Process capability indices of output were all ≥1, some were up to 3–4. While for symmetry, some processes failed to meet the requirements that capability indices were < 1. For different processes of the same daily QA items, the calculated customized limits were quite different. The range of upper control line (UCL) and lower control line (LCL) was smaller for output and the CL was closer to the target value of 0 for flatness and symmetry in the I-MR control chart calculated using data measured by one staff. For different quality control processes without management by the SPC method at our institution, calculated tolerance and action limits of the same measurement item were quite different. And in most measurement items, the specification limits used in the monthly or annual QA procedures in the TG-142 are not suitable to the daily QA procedure. So the analysis method using SPC is useful and necessary.
format Online
Article
Text
id pubmed-8776697
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-87766972022-01-21 Study on the established customized limits for the daily quality assurance procedure Jin, Xiao-Li Song, Jian-Bo Peng, Jin-Xin Pan, Xiao-Peng Guo, Rui Xing, Xiao-Fen J Radiat Res Oncology/Medicine Since there are no corresponding specification limits for some new daily quality assurance (QA) items in the TG-142, it is a compromise that the specification limits used in the monthly or annual QA procedures are used for the daily QA procedure in work. But there is no basis for whether this is feasible. The purpose of this article is to analyze QA results using SPC to determine the tolerance limits at our institution, and to present the usefulness of the analysis method using SPC. The data of three groups daily QA processes performed with Daily QA3 in three years were analyzed using statistical process control (SPC). For calculating capability indices (C(p), C(pk), C(pm) and C(pmk)) of processes, the appropriate number of calculation points was analyzed firstly. Then, in calculating the capability indices for output, limits ±3% of the daily QA in the TG-142 were used as the specification limit, while for flatness and symmetry, an annual QA limits of ±1% was used. For putting forward measures to solve the problem, customized tolerance and action limits were established for each process. And the process control charts calculated using data measured by the five therapists and a medical physicist were compared. At least six to eight weeks of control daily check data points (i.e. 30–40 points) should be used for calculating the individuals and moving range (I-MR) control chart to ensure the stability of control lines. Process capability indices of output were all ≥1, some were up to 3–4. While for symmetry, some processes failed to meet the requirements that capability indices were < 1. For different processes of the same daily QA items, the calculated customized limits were quite different. The range of upper control line (UCL) and lower control line (LCL) was smaller for output and the CL was closer to the target value of 0 for flatness and symmetry in the I-MR control chart calculated using data measured by one staff. For different quality control processes without management by the SPC method at our institution, calculated tolerance and action limits of the same measurement item were quite different. And in most measurement items, the specification limits used in the monthly or annual QA procedures in the TG-142 are not suitable to the daily QA procedure. So the analysis method using SPC is useful and necessary. Oxford University Press 2021-11-03 /pmc/articles/PMC8776697/ /pubmed/34734293 http://dx.doi.org/10.1093/jrr/rrab079 Text en © The Author(s) 2021. Published by Oxford University Press on behalf of The Japanese Radiation Research Society and Japanese Society for Radiation Oncology. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Oncology/Medicine
Jin, Xiao-Li
Song, Jian-Bo
Peng, Jin-Xin
Pan, Xiao-Peng
Guo, Rui
Xing, Xiao-Fen
Study on the established customized limits for the daily quality assurance procedure
title Study on the established customized limits for the daily quality assurance procedure
title_full Study on the established customized limits for the daily quality assurance procedure
title_fullStr Study on the established customized limits for the daily quality assurance procedure
title_full_unstemmed Study on the established customized limits for the daily quality assurance procedure
title_short Study on the established customized limits for the daily quality assurance procedure
title_sort study on the established customized limits for the daily quality assurance procedure
topic Oncology/Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8776697/
https://www.ncbi.nlm.nih.gov/pubmed/34734293
http://dx.doi.org/10.1093/jrr/rrab079
work_keys_str_mv AT jinxiaoli studyontheestablishedcustomizedlimitsforthedailyqualityassuranceprocedure
AT songjianbo studyontheestablishedcustomizedlimitsforthedailyqualityassuranceprocedure
AT pengjinxin studyontheestablishedcustomizedlimitsforthedailyqualityassuranceprocedure
AT panxiaopeng studyontheestablishedcustomizedlimitsforthedailyqualityassuranceprocedure
AT guorui studyontheestablishedcustomizedlimitsforthedailyqualityassuranceprocedure
AT xingxiaofen studyontheestablishedcustomizedlimitsforthedailyqualityassuranceprocedure