Cargando…

Construction of Electrochemical Aptamer Sensor Based on Pt-Coordinated Titanium-Based Porphyrin MOF for Thrombin Detection

In this work, a Pt-coordinated titanium-based porphyrin metal organic framework (Ti-MOF-Pt) was prepared by embedding single-atom Pt through strong interactions between the four pyrrole nitrogen atoms in the rigid backbone of the porphyrin. The synthesized Ti-MOF-Pt was characterized by TEM, XRD, FT...

Descripción completa

Detalles Bibliográficos
Autores principales: Jiang, Jiazi, Cai, Quan, Deng, Minghan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8776986/
https://www.ncbi.nlm.nih.gov/pubmed/35071191
http://dx.doi.org/10.3389/fchem.2021.812983
_version_ 1784636958159405056
author Jiang, Jiazi
Cai, Quan
Deng, Minghan
author_facet Jiang, Jiazi
Cai, Quan
Deng, Minghan
author_sort Jiang, Jiazi
collection PubMed
description In this work, a Pt-coordinated titanium-based porphyrin metal organic framework (Ti-MOF-Pt) was prepared by embedding single-atom Pt through strong interactions between the four pyrrole nitrogen atoms in the rigid backbone of the porphyrin. The synthesized Ti-MOF-Pt was characterized by TEM, XRD, FTIR and BET. Then, the Ti-MOF-Pt has been used for glassy carbon electrode surface modification and consequently used for construction of a thrombin aptamer sensor. The high surface area provides by MOF and excellent electrochemical property provided by Pt enhance the sensing performance. After optimization of amount of aptamer, hybridization time and specific reaction time, the fabricated aptamer sensor exhibited a linear relationship with the logarithm of the thrombin concentration in the range of 4 pM to 0.2 μM. The detection limit can be calculated as 1.3 pM.
format Online
Article
Text
id pubmed-8776986
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-87769862022-01-22 Construction of Electrochemical Aptamer Sensor Based on Pt-Coordinated Titanium-Based Porphyrin MOF for Thrombin Detection Jiang, Jiazi Cai, Quan Deng, Minghan Front Chem Chemistry In this work, a Pt-coordinated titanium-based porphyrin metal organic framework (Ti-MOF-Pt) was prepared by embedding single-atom Pt through strong interactions between the four pyrrole nitrogen atoms in the rigid backbone of the porphyrin. The synthesized Ti-MOF-Pt was characterized by TEM, XRD, FTIR and BET. Then, the Ti-MOF-Pt has been used for glassy carbon electrode surface modification and consequently used for construction of a thrombin aptamer sensor. The high surface area provides by MOF and excellent electrochemical property provided by Pt enhance the sensing performance. After optimization of amount of aptamer, hybridization time and specific reaction time, the fabricated aptamer sensor exhibited a linear relationship with the logarithm of the thrombin concentration in the range of 4 pM to 0.2 μM. The detection limit can be calculated as 1.3 pM. Frontiers Media S.A. 2022-01-07 /pmc/articles/PMC8776986/ /pubmed/35071191 http://dx.doi.org/10.3389/fchem.2021.812983 Text en Copyright © 2022 Jiang, Cai and Deng. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Chemistry
Jiang, Jiazi
Cai, Quan
Deng, Minghan
Construction of Electrochemical Aptamer Sensor Based on Pt-Coordinated Titanium-Based Porphyrin MOF for Thrombin Detection
title Construction of Electrochemical Aptamer Sensor Based on Pt-Coordinated Titanium-Based Porphyrin MOF for Thrombin Detection
title_full Construction of Electrochemical Aptamer Sensor Based on Pt-Coordinated Titanium-Based Porphyrin MOF for Thrombin Detection
title_fullStr Construction of Electrochemical Aptamer Sensor Based on Pt-Coordinated Titanium-Based Porphyrin MOF for Thrombin Detection
title_full_unstemmed Construction of Electrochemical Aptamer Sensor Based on Pt-Coordinated Titanium-Based Porphyrin MOF for Thrombin Detection
title_short Construction of Electrochemical Aptamer Sensor Based on Pt-Coordinated Titanium-Based Porphyrin MOF for Thrombin Detection
title_sort construction of electrochemical aptamer sensor based on pt-coordinated titanium-based porphyrin mof for thrombin detection
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8776986/
https://www.ncbi.nlm.nih.gov/pubmed/35071191
http://dx.doi.org/10.3389/fchem.2021.812983
work_keys_str_mv AT jiangjiazi constructionofelectrochemicalaptamersensorbasedonptcoordinatedtitaniumbasedporphyrinmofforthrombindetection
AT caiquan constructionofelectrochemicalaptamersensorbasedonptcoordinatedtitaniumbasedporphyrinmofforthrombindetection
AT dengminghan constructionofelectrochemicalaptamersensorbasedonptcoordinatedtitaniumbasedporphyrinmofforthrombindetection