Cargando…

Is a small-caliber or large-caliber endoscope more suitable for colonic self-expandable metallic stent placement? A randomized controlled study

OBJECTIVES: The colonic self-expandable metallic stent (C-SEMS) with a 9-French (Fr) delivery system allows for a small-caliber endoscope (SCE) to be used to treat malignant colonic obstruction. Despite the lack of evidence, the SCE has become popular because it is considered easier to insert than t...

Descripción completa

Detalles Bibliográficos
Autores principales: Minoda, Yosuke, Ogino, Haruei, Sumida, Yorinobu, Osoegawa, Takashi, Itaba, Soichi, Hashimoto, Norikazu, Esaki, Mitsuru, Kitagawa, Yusuke, Yodoe, Kentaro, Iboshi, Yoichiro, Matsuguchi, Takahiro, Tadokoro, Mei, Chaen, Tomohito, Kubo, Hiroaki, Kubokawa, Masaru, Harada, Naohiko, Nishizima, Kenichi, Fujii, Hiroyuki, Hata, Yoshitaka, Tanaka, Yoshimasa, Ihara, Eikichi, Ogawa, Yoshihiro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8777335/
https://www.ncbi.nlm.nih.gov/pubmed/35069801
http://dx.doi.org/10.1177/17562848211065331
_version_ 1784637047077601280
author Minoda, Yosuke
Ogino, Haruei
Sumida, Yorinobu
Osoegawa, Takashi
Itaba, Soichi
Hashimoto, Norikazu
Esaki, Mitsuru
Kitagawa, Yusuke
Yodoe, Kentaro
Iboshi, Yoichiro
Matsuguchi, Takahiro
Tadokoro, Mei
Chaen, Tomohito
Kubo, Hiroaki
Kubokawa, Masaru
Harada, Naohiko
Nishizima, Kenichi
Fujii, Hiroyuki
Hata, Yoshitaka
Tanaka, Yoshimasa
Ihara, Eikichi
Ogawa, Yoshihiro
author_facet Minoda, Yosuke
Ogino, Haruei
Sumida, Yorinobu
Osoegawa, Takashi
Itaba, Soichi
Hashimoto, Norikazu
Esaki, Mitsuru
Kitagawa, Yusuke
Yodoe, Kentaro
Iboshi, Yoichiro
Matsuguchi, Takahiro
Tadokoro, Mei
Chaen, Tomohito
Kubo, Hiroaki
Kubokawa, Masaru
Harada, Naohiko
Nishizima, Kenichi
Fujii, Hiroyuki
Hata, Yoshitaka
Tanaka, Yoshimasa
Ihara, Eikichi
Ogawa, Yoshihiro
author_sort Minoda, Yosuke
collection PubMed
description OBJECTIVES: The colonic self-expandable metallic stent (C-SEMS) with a 9-French (Fr) delivery system allows for a small-caliber endoscope (SCE) to be used to treat malignant colonic obstruction. Despite the lack of evidence, the SCE has become popular because it is considered easier to insert than the large-caliber endoscope (LCE). We aimed to determine whether the SCE is more suitable than the LCE for C-SEMS placement. METHODS: Between July 2018 and November 2019, 50 consecutive patients who were scheduled to undergo C-SEMS for colon obstruction were recruited in this study. Patients were randomized to the SCE or LCE group. The SCE and LCE were used with 9-Fr and 10-Fr delivery systems, respectively. The primary outcome was the total procedure time. Secondary outcomes were the technical success rate, complication rate, clinical success rate, insertion time, guidewire-passage time, stent-deployment time, and colonic obstruction-scoring-system score. RESULTS: Forty-five patients (SCE group, n = 22; LCE group, n = 23) were analyzed. The procedure time in the LCE group (median, 20.5 min) was significantly (p = 0.024) shorter than that in the SCE group (median, 25.1 min). The insertion time in the LCE group (median, 2.0 min) was significantly (p = 0.0049) shorter than that in the SCE group (median, 6.0 min). A sub-analysis of the procedure difficulties showed that the insertion time in the LCE group (median, 5.0 min) was significantly shorter than that in the SCE group (median, 8.5 min). CONCLUSION: Both LCE and SCE can be used for C-SEMS; however, LCE is more suitable than SCE as it achieved a faster and equally efficacious C-SEMS placement as that of SCE. CLINICAL TRIAL REGISTRATION NUMBER: University Hospital Medical Information Network Clinical Trials Registry (UMIN 32748)
format Online
Article
Text
id pubmed-8777335
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-87773352022-01-22 Is a small-caliber or large-caliber endoscope more suitable for colonic self-expandable metallic stent placement? A randomized controlled study Minoda, Yosuke Ogino, Haruei Sumida, Yorinobu Osoegawa, Takashi Itaba, Soichi Hashimoto, Norikazu Esaki, Mitsuru Kitagawa, Yusuke Yodoe, Kentaro Iboshi, Yoichiro Matsuguchi, Takahiro Tadokoro, Mei Chaen, Tomohito Kubo, Hiroaki Kubokawa, Masaru Harada, Naohiko Nishizima, Kenichi Fujii, Hiroyuki Hata, Yoshitaka Tanaka, Yoshimasa Ihara, Eikichi Ogawa, Yoshihiro Therap Adv Gastroenterol Original Research OBJECTIVES: The colonic self-expandable metallic stent (C-SEMS) with a 9-French (Fr) delivery system allows for a small-caliber endoscope (SCE) to be used to treat malignant colonic obstruction. Despite the lack of evidence, the SCE has become popular because it is considered easier to insert than the large-caliber endoscope (LCE). We aimed to determine whether the SCE is more suitable than the LCE for C-SEMS placement. METHODS: Between July 2018 and November 2019, 50 consecutive patients who were scheduled to undergo C-SEMS for colon obstruction were recruited in this study. Patients were randomized to the SCE or LCE group. The SCE and LCE were used with 9-Fr and 10-Fr delivery systems, respectively. The primary outcome was the total procedure time. Secondary outcomes were the technical success rate, complication rate, clinical success rate, insertion time, guidewire-passage time, stent-deployment time, and colonic obstruction-scoring-system score. RESULTS: Forty-five patients (SCE group, n = 22; LCE group, n = 23) were analyzed. The procedure time in the LCE group (median, 20.5 min) was significantly (p = 0.024) shorter than that in the SCE group (median, 25.1 min). The insertion time in the LCE group (median, 2.0 min) was significantly (p = 0.0049) shorter than that in the SCE group (median, 6.0 min). A sub-analysis of the procedure difficulties showed that the insertion time in the LCE group (median, 5.0 min) was significantly shorter than that in the SCE group (median, 8.5 min). CONCLUSION: Both LCE and SCE can be used for C-SEMS; however, LCE is more suitable than SCE as it achieved a faster and equally efficacious C-SEMS placement as that of SCE. CLINICAL TRIAL REGISTRATION NUMBER: University Hospital Medical Information Network Clinical Trials Registry (UMIN 32748) SAGE Publications 2022-01-13 /pmc/articles/PMC8777335/ /pubmed/35069801 http://dx.doi.org/10.1177/17562848211065331 Text en © The Author(s), 2022 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Research
Minoda, Yosuke
Ogino, Haruei
Sumida, Yorinobu
Osoegawa, Takashi
Itaba, Soichi
Hashimoto, Norikazu
Esaki, Mitsuru
Kitagawa, Yusuke
Yodoe, Kentaro
Iboshi, Yoichiro
Matsuguchi, Takahiro
Tadokoro, Mei
Chaen, Tomohito
Kubo, Hiroaki
Kubokawa, Masaru
Harada, Naohiko
Nishizima, Kenichi
Fujii, Hiroyuki
Hata, Yoshitaka
Tanaka, Yoshimasa
Ihara, Eikichi
Ogawa, Yoshihiro
Is a small-caliber or large-caliber endoscope more suitable for colonic self-expandable metallic stent placement? A randomized controlled study
title Is a small-caliber or large-caliber endoscope more suitable for colonic self-expandable metallic stent placement? A randomized controlled study
title_full Is a small-caliber or large-caliber endoscope more suitable for colonic self-expandable metallic stent placement? A randomized controlled study
title_fullStr Is a small-caliber or large-caliber endoscope more suitable for colonic self-expandable metallic stent placement? A randomized controlled study
title_full_unstemmed Is a small-caliber or large-caliber endoscope more suitable for colonic self-expandable metallic stent placement? A randomized controlled study
title_short Is a small-caliber or large-caliber endoscope more suitable for colonic self-expandable metallic stent placement? A randomized controlled study
title_sort is a small-caliber or large-caliber endoscope more suitable for colonic self-expandable metallic stent placement? a randomized controlled study
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8777335/
https://www.ncbi.nlm.nih.gov/pubmed/35069801
http://dx.doi.org/10.1177/17562848211065331
work_keys_str_mv AT minodayosuke isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy
AT oginoharuei isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy
AT sumidayorinobu isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy
AT osoegawatakashi isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy
AT itabasoichi isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy
AT hashimotonorikazu isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy
AT esakimitsuru isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy
AT kitagawayusuke isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy
AT yodoekentaro isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy
AT iboshiyoichiro isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy
AT matsuguchitakahiro isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy
AT tadokoromei isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy
AT chaentomohito isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy
AT kubohiroaki isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy
AT kubokawamasaru isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy
AT haradanaohiko isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy
AT nishizimakenichi isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy
AT fujiihiroyuki isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy
AT hatayoshitaka isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy
AT tanakayoshimasa isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy
AT iharaeikichi isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy
AT ogawayoshihiro isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy