Cargando…
Is a small-caliber or large-caliber endoscope more suitable for colonic self-expandable metallic stent placement? A randomized controlled study
OBJECTIVES: The colonic self-expandable metallic stent (C-SEMS) with a 9-French (Fr) delivery system allows for a small-caliber endoscope (SCE) to be used to treat malignant colonic obstruction. Despite the lack of evidence, the SCE has become popular because it is considered easier to insert than t...
Autores principales: | , , , , , , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8777335/ https://www.ncbi.nlm.nih.gov/pubmed/35069801 http://dx.doi.org/10.1177/17562848211065331 |
_version_ | 1784637047077601280 |
---|---|
author | Minoda, Yosuke Ogino, Haruei Sumida, Yorinobu Osoegawa, Takashi Itaba, Soichi Hashimoto, Norikazu Esaki, Mitsuru Kitagawa, Yusuke Yodoe, Kentaro Iboshi, Yoichiro Matsuguchi, Takahiro Tadokoro, Mei Chaen, Tomohito Kubo, Hiroaki Kubokawa, Masaru Harada, Naohiko Nishizima, Kenichi Fujii, Hiroyuki Hata, Yoshitaka Tanaka, Yoshimasa Ihara, Eikichi Ogawa, Yoshihiro |
author_facet | Minoda, Yosuke Ogino, Haruei Sumida, Yorinobu Osoegawa, Takashi Itaba, Soichi Hashimoto, Norikazu Esaki, Mitsuru Kitagawa, Yusuke Yodoe, Kentaro Iboshi, Yoichiro Matsuguchi, Takahiro Tadokoro, Mei Chaen, Tomohito Kubo, Hiroaki Kubokawa, Masaru Harada, Naohiko Nishizima, Kenichi Fujii, Hiroyuki Hata, Yoshitaka Tanaka, Yoshimasa Ihara, Eikichi Ogawa, Yoshihiro |
author_sort | Minoda, Yosuke |
collection | PubMed |
description | OBJECTIVES: The colonic self-expandable metallic stent (C-SEMS) with a 9-French (Fr) delivery system allows for a small-caliber endoscope (SCE) to be used to treat malignant colonic obstruction. Despite the lack of evidence, the SCE has become popular because it is considered easier to insert than the large-caliber endoscope (LCE). We aimed to determine whether the SCE is more suitable than the LCE for C-SEMS placement. METHODS: Between July 2018 and November 2019, 50 consecutive patients who were scheduled to undergo C-SEMS for colon obstruction were recruited in this study. Patients were randomized to the SCE or LCE group. The SCE and LCE were used with 9-Fr and 10-Fr delivery systems, respectively. The primary outcome was the total procedure time. Secondary outcomes were the technical success rate, complication rate, clinical success rate, insertion time, guidewire-passage time, stent-deployment time, and colonic obstruction-scoring-system score. RESULTS: Forty-five patients (SCE group, n = 22; LCE group, n = 23) were analyzed. The procedure time in the LCE group (median, 20.5 min) was significantly (p = 0.024) shorter than that in the SCE group (median, 25.1 min). The insertion time in the LCE group (median, 2.0 min) was significantly (p = 0.0049) shorter than that in the SCE group (median, 6.0 min). A sub-analysis of the procedure difficulties showed that the insertion time in the LCE group (median, 5.0 min) was significantly shorter than that in the SCE group (median, 8.5 min). CONCLUSION: Both LCE and SCE can be used for C-SEMS; however, LCE is more suitable than SCE as it achieved a faster and equally efficacious C-SEMS placement as that of SCE. CLINICAL TRIAL REGISTRATION NUMBER: University Hospital Medical Information Network Clinical Trials Registry (UMIN 32748) |
format | Online Article Text |
id | pubmed-8777335 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-87773352022-01-22 Is a small-caliber or large-caliber endoscope more suitable for colonic self-expandable metallic stent placement? A randomized controlled study Minoda, Yosuke Ogino, Haruei Sumida, Yorinobu Osoegawa, Takashi Itaba, Soichi Hashimoto, Norikazu Esaki, Mitsuru Kitagawa, Yusuke Yodoe, Kentaro Iboshi, Yoichiro Matsuguchi, Takahiro Tadokoro, Mei Chaen, Tomohito Kubo, Hiroaki Kubokawa, Masaru Harada, Naohiko Nishizima, Kenichi Fujii, Hiroyuki Hata, Yoshitaka Tanaka, Yoshimasa Ihara, Eikichi Ogawa, Yoshihiro Therap Adv Gastroenterol Original Research OBJECTIVES: The colonic self-expandable metallic stent (C-SEMS) with a 9-French (Fr) delivery system allows for a small-caliber endoscope (SCE) to be used to treat malignant colonic obstruction. Despite the lack of evidence, the SCE has become popular because it is considered easier to insert than the large-caliber endoscope (LCE). We aimed to determine whether the SCE is more suitable than the LCE for C-SEMS placement. METHODS: Between July 2018 and November 2019, 50 consecutive patients who were scheduled to undergo C-SEMS for colon obstruction were recruited in this study. Patients were randomized to the SCE or LCE group. The SCE and LCE were used with 9-Fr and 10-Fr delivery systems, respectively. The primary outcome was the total procedure time. Secondary outcomes were the technical success rate, complication rate, clinical success rate, insertion time, guidewire-passage time, stent-deployment time, and colonic obstruction-scoring-system score. RESULTS: Forty-five patients (SCE group, n = 22; LCE group, n = 23) were analyzed. The procedure time in the LCE group (median, 20.5 min) was significantly (p = 0.024) shorter than that in the SCE group (median, 25.1 min). The insertion time in the LCE group (median, 2.0 min) was significantly (p = 0.0049) shorter than that in the SCE group (median, 6.0 min). A sub-analysis of the procedure difficulties showed that the insertion time in the LCE group (median, 5.0 min) was significantly shorter than that in the SCE group (median, 8.5 min). CONCLUSION: Both LCE and SCE can be used for C-SEMS; however, LCE is more suitable than SCE as it achieved a faster and equally efficacious C-SEMS placement as that of SCE. CLINICAL TRIAL REGISTRATION NUMBER: University Hospital Medical Information Network Clinical Trials Registry (UMIN 32748) SAGE Publications 2022-01-13 /pmc/articles/PMC8777335/ /pubmed/35069801 http://dx.doi.org/10.1177/17562848211065331 Text en © The Author(s), 2022 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Research Minoda, Yosuke Ogino, Haruei Sumida, Yorinobu Osoegawa, Takashi Itaba, Soichi Hashimoto, Norikazu Esaki, Mitsuru Kitagawa, Yusuke Yodoe, Kentaro Iboshi, Yoichiro Matsuguchi, Takahiro Tadokoro, Mei Chaen, Tomohito Kubo, Hiroaki Kubokawa, Masaru Harada, Naohiko Nishizima, Kenichi Fujii, Hiroyuki Hata, Yoshitaka Tanaka, Yoshimasa Ihara, Eikichi Ogawa, Yoshihiro Is a small-caliber or large-caliber endoscope more suitable for colonic self-expandable metallic stent placement? A randomized controlled study |
title | Is a small-caliber or large-caliber endoscope more suitable for
colonic self-expandable metallic stent placement? A randomized controlled
study |
title_full | Is a small-caliber or large-caliber endoscope more suitable for
colonic self-expandable metallic stent placement? A randomized controlled
study |
title_fullStr | Is a small-caliber or large-caliber endoscope more suitable for
colonic self-expandable metallic stent placement? A randomized controlled
study |
title_full_unstemmed | Is a small-caliber or large-caliber endoscope more suitable for
colonic self-expandable metallic stent placement? A randomized controlled
study |
title_short | Is a small-caliber or large-caliber endoscope more suitable for
colonic self-expandable metallic stent placement? A randomized controlled
study |
title_sort | is a small-caliber or large-caliber endoscope more suitable for
colonic self-expandable metallic stent placement? a randomized controlled
study |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8777335/ https://www.ncbi.nlm.nih.gov/pubmed/35069801 http://dx.doi.org/10.1177/17562848211065331 |
work_keys_str_mv | AT minodayosuke isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy AT oginoharuei isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy AT sumidayorinobu isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy AT osoegawatakashi isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy AT itabasoichi isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy AT hashimotonorikazu isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy AT esakimitsuru isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy AT kitagawayusuke isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy AT yodoekentaro isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy AT iboshiyoichiro isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy AT matsuguchitakahiro isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy AT tadokoromei isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy AT chaentomohito isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy AT kubohiroaki isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy AT kubokawamasaru isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy AT haradanaohiko isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy AT nishizimakenichi isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy AT fujiihiroyuki isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy AT hatayoshitaka isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy AT tanakayoshimasa isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy AT iharaeikichi isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy AT ogawayoshihiro isasmallcaliberorlargecaliberendoscopemoresuitableforcolonicselfexpandablemetallicstentplacementarandomizedcontrolledstudy |