Cargando…

A Simple Method for the Detection of Biofilms Using a Heatable Capacitive Sensor Structure (CSS): Description, Proof of Concept, and Some Technical Improvements

This article presents a novel method for the detection of biofilms based on a heatable, capacitive sensor structure (CSS). Biofilms are capable of strongly binding large amounts of water to their extracellular biopolymer matrix, which is detectable via its dielectric properties. A main challenge is...

Descripción completa

Detalles Bibliográficos
Autores principales: Zirk, Kai-Uwe, Olze, Manuel, Pötzschke, Harald
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8778368/
https://www.ncbi.nlm.nih.gov/pubmed/35062406
http://dx.doi.org/10.3390/s22020445
_version_ 1784637304328945664
author Zirk, Kai-Uwe
Olze, Manuel
Pötzschke, Harald
author_facet Zirk, Kai-Uwe
Olze, Manuel
Pötzschke, Harald
author_sort Zirk, Kai-Uwe
collection PubMed
description This article presents a novel method for the detection of biofilms based on a heatable, capacitive sensor structure (CSS). Biofilms are capable of strongly binding large amounts of water to their extracellular biopolymer matrix, which is detectable via its dielectric properties. A main challenge is to determine the difference between the inherent occurring presence of moisture in the ecosystem, which is necessary to form a biofilm and an actual formed biofilm. Therefore, the CSS is carefully heated to evaporate unbound surface moisture and determine whether there is a remaining residual alternation of the capacitance in comparison to the dry state. As a reproduceable substitute for complex, real biofilms, a hygroscopic, medical hydrogel-based on polysaccharides was used and applied by spray coating. Printed circuit boards (PCB) in different geometries and materials were used as CSS and compared in terms of their performance. A layer-thickness of 20 µm for the hydrogel coating to be sufficiently detected was defined as a realistic condition based on known values for real biofilms cited in literature. For this thickness a double-meander structure proves to be preferable over interdigitating and spiral geometries. It does offer a 30% lower, yet sufficient sensitivity, but shows advantages in manufacturing (one layer instead of two) and conductive heating capability. In the experiments, free water showed virtually no residual change, while the hydrogel-coated CSS still shows an approx. 300% higher value compared to a dry capacity. Yet, the overall small capacities of about 6–30 pF in dry state are difficult to measure and therefore sensitive to interferences and noise, which results in a high deviation. The principle of measurement can be evaluated as proofed by the carried out experiments, though offering room for improvement in the design of the study. The new method might be especially useful for pipes (e.g., hydrodynamically ineffective sensors installed in a pipe wall) if they at least are not permanently flooded with an aqueous medium, but can occasionally dry. If the internal surface is still only moist, it can be dried by initial heating.
format Online
Article
Text
id pubmed-8778368
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-87783682022-01-22 A Simple Method for the Detection of Biofilms Using a Heatable Capacitive Sensor Structure (CSS): Description, Proof of Concept, and Some Technical Improvements Zirk, Kai-Uwe Olze, Manuel Pötzschke, Harald Sensors (Basel) Article This article presents a novel method for the detection of biofilms based on a heatable, capacitive sensor structure (CSS). Biofilms are capable of strongly binding large amounts of water to their extracellular biopolymer matrix, which is detectable via its dielectric properties. A main challenge is to determine the difference between the inherent occurring presence of moisture in the ecosystem, which is necessary to form a biofilm and an actual formed biofilm. Therefore, the CSS is carefully heated to evaporate unbound surface moisture and determine whether there is a remaining residual alternation of the capacitance in comparison to the dry state. As a reproduceable substitute for complex, real biofilms, a hygroscopic, medical hydrogel-based on polysaccharides was used and applied by spray coating. Printed circuit boards (PCB) in different geometries and materials were used as CSS and compared in terms of their performance. A layer-thickness of 20 µm for the hydrogel coating to be sufficiently detected was defined as a realistic condition based on known values for real biofilms cited in literature. For this thickness a double-meander structure proves to be preferable over interdigitating and spiral geometries. It does offer a 30% lower, yet sufficient sensitivity, but shows advantages in manufacturing (one layer instead of two) and conductive heating capability. In the experiments, free water showed virtually no residual change, while the hydrogel-coated CSS still shows an approx. 300% higher value compared to a dry capacity. Yet, the overall small capacities of about 6–30 pF in dry state are difficult to measure and therefore sensitive to interferences and noise, which results in a high deviation. The principle of measurement can be evaluated as proofed by the carried out experiments, though offering room for improvement in the design of the study. The new method might be especially useful for pipes (e.g., hydrodynamically ineffective sensors installed in a pipe wall) if they at least are not permanently flooded with an aqueous medium, but can occasionally dry. If the internal surface is still only moist, it can be dried by initial heating. MDPI 2022-01-07 /pmc/articles/PMC8778368/ /pubmed/35062406 http://dx.doi.org/10.3390/s22020445 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zirk, Kai-Uwe
Olze, Manuel
Pötzschke, Harald
A Simple Method for the Detection of Biofilms Using a Heatable Capacitive Sensor Structure (CSS): Description, Proof of Concept, and Some Technical Improvements
title A Simple Method for the Detection of Biofilms Using a Heatable Capacitive Sensor Structure (CSS): Description, Proof of Concept, and Some Technical Improvements
title_full A Simple Method for the Detection of Biofilms Using a Heatable Capacitive Sensor Structure (CSS): Description, Proof of Concept, and Some Technical Improvements
title_fullStr A Simple Method for the Detection of Biofilms Using a Heatable Capacitive Sensor Structure (CSS): Description, Proof of Concept, and Some Technical Improvements
title_full_unstemmed A Simple Method for the Detection of Biofilms Using a Heatable Capacitive Sensor Structure (CSS): Description, Proof of Concept, and Some Technical Improvements
title_short A Simple Method for the Detection of Biofilms Using a Heatable Capacitive Sensor Structure (CSS): Description, Proof of Concept, and Some Technical Improvements
title_sort simple method for the detection of biofilms using a heatable capacitive sensor structure (css): description, proof of concept, and some technical improvements
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8778368/
https://www.ncbi.nlm.nih.gov/pubmed/35062406
http://dx.doi.org/10.3390/s22020445
work_keys_str_mv AT zirkkaiuwe asimplemethodforthedetectionofbiofilmsusingaheatablecapacitivesensorstructurecssdescriptionproofofconceptandsometechnicalimprovements
AT olzemanuel asimplemethodforthedetectionofbiofilmsusingaheatablecapacitivesensorstructurecssdescriptionproofofconceptandsometechnicalimprovements
AT potzschkeharald asimplemethodforthedetectionofbiofilmsusingaheatablecapacitivesensorstructurecssdescriptionproofofconceptandsometechnicalimprovements
AT zirkkaiuwe simplemethodforthedetectionofbiofilmsusingaheatablecapacitivesensorstructurecssdescriptionproofofconceptandsometechnicalimprovements
AT olzemanuel simplemethodforthedetectionofbiofilmsusingaheatablecapacitivesensorstructurecssdescriptionproofofconceptandsometechnicalimprovements
AT potzschkeharald simplemethodforthedetectionofbiofilmsusingaheatablecapacitivesensorstructurecssdescriptionproofofconceptandsometechnicalimprovements