Cargando…

Measurement of Wire Deflection on Loading may Indicate Union in Ilizarov Constructs: A Pilot Study

INTRODUCTION: No entirely reliable method to assess union during Ilizarov treatment exists. Premature frame removal results in treatment failure, and alternative methods of assessment warrant investigation. Wire deflection might provide an indication of fracture site deformation on weight-bearing, i...

Descripción completa

Detalles Bibliográficos
Autores principales: Lineham, Beth, Stewart, Todd, Ward, John, Harwood, Paul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Jaypee Brothers Medical Publishers 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8778728/
https://www.ncbi.nlm.nih.gov/pubmed/35111251
http://dx.doi.org/10.5005/jp-journals-10080-1537
_version_ 1784637394040913920
author Lineham, Beth
Stewart, Todd
Ward, John
Harwood, Paul
author_facet Lineham, Beth
Stewart, Todd
Ward, John
Harwood, Paul
author_sort Lineham, Beth
collection PubMed
description INTRODUCTION: No entirely reliable method to assess union during Ilizarov treatment exists. Premature frame removal results in treatment failure, and alternative methods of assessment warrant investigation. Wire deflection might provide an indication of fracture site deformation on weight-bearing, indicating progress towards union. A previous in vitro study from our group demonstrated this approach may be clinically applicable. We investigated translation of this method into clinical practice in an observational pilot study. MATERIALS AND METHODS: Patients with tibial shaft fractures treated with Ilizarov frames were recruited. A prototype depth gauge was used to measure wire deflection on weight-bearing. Investigators undertaking the measurement were blinded to the clinical stage of treatment, and clinicians caring for the patient were blinded to deflection results. Patient records were reviewed at the end of treatment to determine likely fracture stability at each time point. Deflection per kg of weight applied, per mm from the ring was compared between stable and unstable situations. RESULTS: Thirty-one measurements were obtained in 14 patients. The situation was deemed stable at 13 and unstable at 18 measurements. The median deflection in the stable group was 0.030 microns/kg/mm (IQR 0.005–0.104) and 0.165 microns/kg/mm (IQR 0.072–0.328) in the unstable group. This difference was statistically significant (Wilcoxon Mann–Whitney test p = 0.0014). ROC curve analysis revealed that wire deflection was able to predict clinical stability (AUC 0.84, p <0.0001). Various technical problems were encountered when using the device which would potentially limit its clinical utility in its current form. CONCLUSION: In this set of observations, wire deflection was significantly associated with clinically and radiologically determined stability. Though various practical limitations were encountered in using the prototype measurement device, this proof-of-concept study supports further development of this approach. The research group plan to develop a smaller, more reliable device for further clinical testing in a larger group of patients. HOW TO CITE THIS ARTICLE: Lineham B, Stewart T, Ward J, et al. Measurement of Wire Deflection on Loading may Indicate Union in Ilizarov Constructs: A Pilot Study. Strategies Trauma Limb Reconstr 2021;16(3):132–137.
format Online
Article
Text
id pubmed-8778728
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Jaypee Brothers Medical Publishers
record_format MEDLINE/PubMed
spelling pubmed-87787282022-02-01 Measurement of Wire Deflection on Loading may Indicate Union in Ilizarov Constructs: A Pilot Study Lineham, Beth Stewart, Todd Ward, John Harwood, Paul Strategies Trauma Limb Reconstr Original Research INTRODUCTION: No entirely reliable method to assess union during Ilizarov treatment exists. Premature frame removal results in treatment failure, and alternative methods of assessment warrant investigation. Wire deflection might provide an indication of fracture site deformation on weight-bearing, indicating progress towards union. A previous in vitro study from our group demonstrated this approach may be clinically applicable. We investigated translation of this method into clinical practice in an observational pilot study. MATERIALS AND METHODS: Patients with tibial shaft fractures treated with Ilizarov frames were recruited. A prototype depth gauge was used to measure wire deflection on weight-bearing. Investigators undertaking the measurement were blinded to the clinical stage of treatment, and clinicians caring for the patient were blinded to deflection results. Patient records were reviewed at the end of treatment to determine likely fracture stability at each time point. Deflection per kg of weight applied, per mm from the ring was compared between stable and unstable situations. RESULTS: Thirty-one measurements were obtained in 14 patients. The situation was deemed stable at 13 and unstable at 18 measurements. The median deflection in the stable group was 0.030 microns/kg/mm (IQR 0.005–0.104) and 0.165 microns/kg/mm (IQR 0.072–0.328) in the unstable group. This difference was statistically significant (Wilcoxon Mann–Whitney test p = 0.0014). ROC curve analysis revealed that wire deflection was able to predict clinical stability (AUC 0.84, p <0.0001). Various technical problems were encountered when using the device which would potentially limit its clinical utility in its current form. CONCLUSION: In this set of observations, wire deflection was significantly associated with clinically and radiologically determined stability. Though various practical limitations were encountered in using the prototype measurement device, this proof-of-concept study supports further development of this approach. The research group plan to develop a smaller, more reliable device for further clinical testing in a larger group of patients. HOW TO CITE THIS ARTICLE: Lineham B, Stewart T, Ward J, et al. Measurement of Wire Deflection on Loading may Indicate Union in Ilizarov Constructs: A Pilot Study. Strategies Trauma Limb Reconstr 2021;16(3):132–137. Jaypee Brothers Medical Publishers 2021 /pmc/articles/PMC8778728/ /pubmed/35111251 http://dx.doi.org/10.5005/jp-journals-10080-1537 Text en Copyright © 2021; The Author(s). https://creativecommons.org/licenses/by-nc-sa/4.0/© The Author(s). 2021 Open Access This article is distributed under the terms of the Creative Commons Attribution-Non Commercial-share alike license (https://creativecommons.org/licenses/by-nc-sa/4.0/) which permits unrestricted distribution, and non-commercial reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. If you remix, transform, or build upon the material, you must distribute your contributions under the same license as original. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated.
spellingShingle Original Research
Lineham, Beth
Stewart, Todd
Ward, John
Harwood, Paul
Measurement of Wire Deflection on Loading may Indicate Union in Ilizarov Constructs: A Pilot Study
title Measurement of Wire Deflection on Loading may Indicate Union in Ilizarov Constructs: A Pilot Study
title_full Measurement of Wire Deflection on Loading may Indicate Union in Ilizarov Constructs: A Pilot Study
title_fullStr Measurement of Wire Deflection on Loading may Indicate Union in Ilizarov Constructs: A Pilot Study
title_full_unstemmed Measurement of Wire Deflection on Loading may Indicate Union in Ilizarov Constructs: A Pilot Study
title_short Measurement of Wire Deflection on Loading may Indicate Union in Ilizarov Constructs: A Pilot Study
title_sort measurement of wire deflection on loading may indicate union in ilizarov constructs: a pilot study
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8778728/
https://www.ncbi.nlm.nih.gov/pubmed/35111251
http://dx.doi.org/10.5005/jp-journals-10080-1537
work_keys_str_mv AT linehambeth measurementofwiredeflectiononloadingmayindicateunioninilizarovconstructsapilotstudy
AT stewarttodd measurementofwiredeflectiononloadingmayindicateunioninilizarovconstructsapilotstudy
AT wardjohn measurementofwiredeflectiononloadingmayindicateunioninilizarovconstructsapilotstudy
AT harwoodpaul measurementofwiredeflectiononloadingmayindicateunioninilizarovconstructsapilotstudy