Cargando…

Markerless Image Alignment Method for Pressure-Sensitive Paint Image

We propose a markerless image alignment method for pressure-sensitive paint measurement data replacing the time-consuming conventional alignment method in which the black markers are placed on the model and are detected manually. In the proposed method, feature points are detected by a boundary dete...

Descripción completa

Detalles Bibliográficos
Autores principales: Suzuki, Kyosuke, Inoue, Tomoki, Nagata, Takayuki, Kasai, Miku, Nonomura, Taku, Matsuda, Yu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8778811/
https://www.ncbi.nlm.nih.gov/pubmed/35062414
http://dx.doi.org/10.3390/s22020453
_version_ 1784637414703104000
author Suzuki, Kyosuke
Inoue, Tomoki
Nagata, Takayuki
Kasai, Miku
Nonomura, Taku
Matsuda, Yu
author_facet Suzuki, Kyosuke
Inoue, Tomoki
Nagata, Takayuki
Kasai, Miku
Nonomura, Taku
Matsuda, Yu
author_sort Suzuki, Kyosuke
collection PubMed
description We propose a markerless image alignment method for pressure-sensitive paint measurement data replacing the time-consuming conventional alignment method in which the black markers are placed on the model and are detected manually. In the proposed method, feature points are detected by a boundary detection method, in which the PSP boundary is detected using the Moore-Neighbor tracing algorithm. The performance of the proposed method is compared with the conventional method based on black markers, the difference of Gaussian (DoG) detector, and the Hessian corner detector. The results by the proposed method and the DoG detector are equivalent to each other. On the other hand, the performances of the image alignment using the black marker and the Hessian corner detector are slightly worse compared with the DoG and the proposed method. The computational cost of the proposed method is half of that of the DoG method. The proposed method is a promising for the image alignment in the PSP application in the viewpoint of the alignment precision and computational cost.
format Online
Article
Text
id pubmed-8778811
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-87788112022-01-22 Markerless Image Alignment Method for Pressure-Sensitive Paint Image Suzuki, Kyosuke Inoue, Tomoki Nagata, Takayuki Kasai, Miku Nonomura, Taku Matsuda, Yu Sensors (Basel) Communication We propose a markerless image alignment method for pressure-sensitive paint measurement data replacing the time-consuming conventional alignment method in which the black markers are placed on the model and are detected manually. In the proposed method, feature points are detected by a boundary detection method, in which the PSP boundary is detected using the Moore-Neighbor tracing algorithm. The performance of the proposed method is compared with the conventional method based on black markers, the difference of Gaussian (DoG) detector, and the Hessian corner detector. The results by the proposed method and the DoG detector are equivalent to each other. On the other hand, the performances of the image alignment using the black marker and the Hessian corner detector are slightly worse compared with the DoG and the proposed method. The computational cost of the proposed method is half of that of the DoG method. The proposed method is a promising for the image alignment in the PSP application in the viewpoint of the alignment precision and computational cost. MDPI 2022-01-07 /pmc/articles/PMC8778811/ /pubmed/35062414 http://dx.doi.org/10.3390/s22020453 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Communication
Suzuki, Kyosuke
Inoue, Tomoki
Nagata, Takayuki
Kasai, Miku
Nonomura, Taku
Matsuda, Yu
Markerless Image Alignment Method for Pressure-Sensitive Paint Image
title Markerless Image Alignment Method for Pressure-Sensitive Paint Image
title_full Markerless Image Alignment Method for Pressure-Sensitive Paint Image
title_fullStr Markerless Image Alignment Method for Pressure-Sensitive Paint Image
title_full_unstemmed Markerless Image Alignment Method for Pressure-Sensitive Paint Image
title_short Markerless Image Alignment Method for Pressure-Sensitive Paint Image
title_sort markerless image alignment method for pressure-sensitive paint image
topic Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8778811/
https://www.ncbi.nlm.nih.gov/pubmed/35062414
http://dx.doi.org/10.3390/s22020453
work_keys_str_mv AT suzukikyosuke markerlessimagealignmentmethodforpressuresensitivepaintimage
AT inouetomoki markerlessimagealignmentmethodforpressuresensitivepaintimage
AT nagatatakayuki markerlessimagealignmentmethodforpressuresensitivepaintimage
AT kasaimiku markerlessimagealignmentmethodforpressuresensitivepaintimage
AT nonomurataku markerlessimagealignmentmethodforpressuresensitivepaintimage
AT matsudayu markerlessimagealignmentmethodforpressuresensitivepaintimage