Cargando…
Markerless Image Alignment Method for Pressure-Sensitive Paint Image
We propose a markerless image alignment method for pressure-sensitive paint measurement data replacing the time-consuming conventional alignment method in which the black markers are placed on the model and are detected manually. In the proposed method, feature points are detected by a boundary dete...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8778811/ https://www.ncbi.nlm.nih.gov/pubmed/35062414 http://dx.doi.org/10.3390/s22020453 |
_version_ | 1784637414703104000 |
---|---|
author | Suzuki, Kyosuke Inoue, Tomoki Nagata, Takayuki Kasai, Miku Nonomura, Taku Matsuda, Yu |
author_facet | Suzuki, Kyosuke Inoue, Tomoki Nagata, Takayuki Kasai, Miku Nonomura, Taku Matsuda, Yu |
author_sort | Suzuki, Kyosuke |
collection | PubMed |
description | We propose a markerless image alignment method for pressure-sensitive paint measurement data replacing the time-consuming conventional alignment method in which the black markers are placed on the model and are detected manually. In the proposed method, feature points are detected by a boundary detection method, in which the PSP boundary is detected using the Moore-Neighbor tracing algorithm. The performance of the proposed method is compared with the conventional method based on black markers, the difference of Gaussian (DoG) detector, and the Hessian corner detector. The results by the proposed method and the DoG detector are equivalent to each other. On the other hand, the performances of the image alignment using the black marker and the Hessian corner detector are slightly worse compared with the DoG and the proposed method. The computational cost of the proposed method is half of that of the DoG method. The proposed method is a promising for the image alignment in the PSP application in the viewpoint of the alignment precision and computational cost. |
format | Online Article Text |
id | pubmed-8778811 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-87788112022-01-22 Markerless Image Alignment Method for Pressure-Sensitive Paint Image Suzuki, Kyosuke Inoue, Tomoki Nagata, Takayuki Kasai, Miku Nonomura, Taku Matsuda, Yu Sensors (Basel) Communication We propose a markerless image alignment method for pressure-sensitive paint measurement data replacing the time-consuming conventional alignment method in which the black markers are placed on the model and are detected manually. In the proposed method, feature points are detected by a boundary detection method, in which the PSP boundary is detected using the Moore-Neighbor tracing algorithm. The performance of the proposed method is compared with the conventional method based on black markers, the difference of Gaussian (DoG) detector, and the Hessian corner detector. The results by the proposed method and the DoG detector are equivalent to each other. On the other hand, the performances of the image alignment using the black marker and the Hessian corner detector are slightly worse compared with the DoG and the proposed method. The computational cost of the proposed method is half of that of the DoG method. The proposed method is a promising for the image alignment in the PSP application in the viewpoint of the alignment precision and computational cost. MDPI 2022-01-07 /pmc/articles/PMC8778811/ /pubmed/35062414 http://dx.doi.org/10.3390/s22020453 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Communication Suzuki, Kyosuke Inoue, Tomoki Nagata, Takayuki Kasai, Miku Nonomura, Taku Matsuda, Yu Markerless Image Alignment Method for Pressure-Sensitive Paint Image |
title | Markerless Image Alignment Method for Pressure-Sensitive Paint Image |
title_full | Markerless Image Alignment Method for Pressure-Sensitive Paint Image |
title_fullStr | Markerless Image Alignment Method for Pressure-Sensitive Paint Image |
title_full_unstemmed | Markerless Image Alignment Method for Pressure-Sensitive Paint Image |
title_short | Markerless Image Alignment Method for Pressure-Sensitive Paint Image |
title_sort | markerless image alignment method for pressure-sensitive paint image |
topic | Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8778811/ https://www.ncbi.nlm.nih.gov/pubmed/35062414 http://dx.doi.org/10.3390/s22020453 |
work_keys_str_mv | AT suzukikyosuke markerlessimagealignmentmethodforpressuresensitivepaintimage AT inouetomoki markerlessimagealignmentmethodforpressuresensitivepaintimage AT nagatatakayuki markerlessimagealignmentmethodforpressuresensitivepaintimage AT kasaimiku markerlessimagealignmentmethodforpressuresensitivepaintimage AT nonomurataku markerlessimagealignmentmethodforpressuresensitivepaintimage AT matsudayu markerlessimagealignmentmethodforpressuresensitivepaintimage |