Cargando…

Does Resin Cement Type and Cement Preheating Influence the Marginal and Internal Fit of Lithium Disilicate Single Crowns?

This paper assesses the effect of cement type and cement preheating on the marginal and internal fit of lithium disilicate single crown. Methods: 40 maxillary premolars were selected, restored with lithium disilicate single crowns. Teeth were randomly assigned into four groups (n = 10) based on ceme...

Descripción completa

Detalles Bibliográficos
Autores principales: Samy, Nourhan, Al-Zordk, Walid, Elsherbini, Ahmed, Özcan, Mutlu, Sakrana, Amal Abdelsamad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8778998/
https://www.ncbi.nlm.nih.gov/pubmed/35057142
http://dx.doi.org/10.3390/ma15020424
_version_ 1784637463630708736
author Samy, Nourhan
Al-Zordk, Walid
Elsherbini, Ahmed
Özcan, Mutlu
Sakrana, Amal Abdelsamad
author_facet Samy, Nourhan
Al-Zordk, Walid
Elsherbini, Ahmed
Özcan, Mutlu
Sakrana, Amal Abdelsamad
author_sort Samy, Nourhan
collection PubMed
description This paper assesses the effect of cement type and cement preheating on the marginal and internal fit of lithium disilicate single crown. Methods: 40 maxillary premolars were selected, restored with lithium disilicate single crowns. Teeth were randomly assigned into four groups (n = 10) based on cement type (Panavia SA or LinkForce) and preheating temperature (25 °C or 54 °C). After fabrication of the restoration, cements were incubated at 25 °C or 54 °C for 24 h, and each crown was cemented to its corresponding tooth. After 24 h, all specimens were thermally aged to (10,000 thermal cycles between 5 °C and 55 °C), then load cycled for 240,000 cycles. Each specimen was then sectioned in bucco-palatal direction and inspected under a stereomicroscope at x45 magnification for marginal and internal fit evaluation. The data were statistically analyzed (significance at p ≤ 0.05 level). Results: At the mid-buccal finish line, mid-buccal wall, palatal cusp, mid-palatal wall, mid-palatal finish line, and palatal margin measuring points, there was a significant difference (p ≤ 0.05) between the lithium disilicate group cemented with Panavia SA at 25 °C and the group cemented with LinkForce at 25 °C, while there was no significant difference (p > 0.05) at the other points. At all measuring points, except at the palatal cusp tip (p = 0.948) and palatal margin (p = 0.103), there was a statistically significant difference (p ≤ 0.05) between the lithium disilicate group cemented with Panavia SA at 54 °C and the group cemented with LinkForce at 54 °C. Regardless of cement preheating, statistically significant differences were found in the buccal cusp tip, central groove, palatal cusp tip, and mid-palatal wall (p ≤ 0.05) in the lithium disilicate group cemented with Panavia SA at 25 °C and 54 °C, as well as the mid-palatal chamfer finish line and palatal margin in the LinkForce group cemented with Panavia SA at 25 °C and 54 °C. At the other measurement points, however, there was no significant difference (p > 0.05). Conclusions: The type of resin cement affects the internal and marginal fit of lithium disilicate crowns. At most measuring points, the cement preheating does not improve the internal and marginal fit of all lithium disilicate crowns.
format Online
Article
Text
id pubmed-8778998
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-87789982022-01-22 Does Resin Cement Type and Cement Preheating Influence the Marginal and Internal Fit of Lithium Disilicate Single Crowns? Samy, Nourhan Al-Zordk, Walid Elsherbini, Ahmed Özcan, Mutlu Sakrana, Amal Abdelsamad Materials (Basel) Article This paper assesses the effect of cement type and cement preheating on the marginal and internal fit of lithium disilicate single crown. Methods: 40 maxillary premolars were selected, restored with lithium disilicate single crowns. Teeth were randomly assigned into four groups (n = 10) based on cement type (Panavia SA or LinkForce) and preheating temperature (25 °C or 54 °C). After fabrication of the restoration, cements were incubated at 25 °C or 54 °C for 24 h, and each crown was cemented to its corresponding tooth. After 24 h, all specimens were thermally aged to (10,000 thermal cycles between 5 °C and 55 °C), then load cycled for 240,000 cycles. Each specimen was then sectioned in bucco-palatal direction and inspected under a stereomicroscope at x45 magnification for marginal and internal fit evaluation. The data were statistically analyzed (significance at p ≤ 0.05 level). Results: At the mid-buccal finish line, mid-buccal wall, palatal cusp, mid-palatal wall, mid-palatal finish line, and palatal margin measuring points, there was a significant difference (p ≤ 0.05) between the lithium disilicate group cemented with Panavia SA at 25 °C and the group cemented with LinkForce at 25 °C, while there was no significant difference (p > 0.05) at the other points. At all measuring points, except at the palatal cusp tip (p = 0.948) and palatal margin (p = 0.103), there was a statistically significant difference (p ≤ 0.05) between the lithium disilicate group cemented with Panavia SA at 54 °C and the group cemented with LinkForce at 54 °C. Regardless of cement preheating, statistically significant differences were found in the buccal cusp tip, central groove, palatal cusp tip, and mid-palatal wall (p ≤ 0.05) in the lithium disilicate group cemented with Panavia SA at 25 °C and 54 °C, as well as the mid-palatal chamfer finish line and palatal margin in the LinkForce group cemented with Panavia SA at 25 °C and 54 °C. At the other measurement points, however, there was no significant difference (p > 0.05). Conclusions: The type of resin cement affects the internal and marginal fit of lithium disilicate crowns. At most measuring points, the cement preheating does not improve the internal and marginal fit of all lithium disilicate crowns. MDPI 2022-01-06 /pmc/articles/PMC8778998/ /pubmed/35057142 http://dx.doi.org/10.3390/ma15020424 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Samy, Nourhan
Al-Zordk, Walid
Elsherbini, Ahmed
Özcan, Mutlu
Sakrana, Amal Abdelsamad
Does Resin Cement Type and Cement Preheating Influence the Marginal and Internal Fit of Lithium Disilicate Single Crowns?
title Does Resin Cement Type and Cement Preheating Influence the Marginal and Internal Fit of Lithium Disilicate Single Crowns?
title_full Does Resin Cement Type and Cement Preheating Influence the Marginal and Internal Fit of Lithium Disilicate Single Crowns?
title_fullStr Does Resin Cement Type and Cement Preheating Influence the Marginal and Internal Fit of Lithium Disilicate Single Crowns?
title_full_unstemmed Does Resin Cement Type and Cement Preheating Influence the Marginal and Internal Fit of Lithium Disilicate Single Crowns?
title_short Does Resin Cement Type and Cement Preheating Influence the Marginal and Internal Fit of Lithium Disilicate Single Crowns?
title_sort does resin cement type and cement preheating influence the marginal and internal fit of lithium disilicate single crowns?
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8778998/
https://www.ncbi.nlm.nih.gov/pubmed/35057142
http://dx.doi.org/10.3390/ma15020424
work_keys_str_mv AT samynourhan doesresincementtypeandcementpreheatinginfluencethemarginalandinternalfitoflithiumdisilicatesinglecrowns
AT alzordkwalid doesresincementtypeandcementpreheatinginfluencethemarginalandinternalfitoflithiumdisilicatesinglecrowns
AT elsherbiniahmed doesresincementtypeandcementpreheatinginfluencethemarginalandinternalfitoflithiumdisilicatesinglecrowns
AT ozcanmutlu doesresincementtypeandcementpreheatinginfluencethemarginalandinternalfitoflithiumdisilicatesinglecrowns
AT sakranaamalabdelsamad doesresincementtypeandcementpreheatinginfluencethemarginalandinternalfitoflithiumdisilicatesinglecrowns