Cargando…
Influence of (Sub) Structure Development within Rotary Swaged Al–Cu Clad Conductors on Skin Effect during Transfer of Alternating Current
The nature of alternating current transfer via metallic materials is specific, since the current density tends to be inhomogeneous across the cross-section of the conductor and the skin effect tends to occur. However, the influence of this effect on the behaviour of the conductor can be optimized vi...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8779058/ https://www.ncbi.nlm.nih.gov/pubmed/35057368 http://dx.doi.org/10.3390/ma15020650 |
_version_ | 1784637478008782848 |
---|---|
author | Kunčická, Lenka Kocich, Radim Kačor, Petr Jambor, Michal Jopek, Miroslav |
author_facet | Kunčická, Lenka Kocich, Radim Kačor, Petr Jambor, Michal Jopek, Miroslav |
author_sort | Kunčická, Lenka |
collection | PubMed |
description | The nature of alternating current transfer via metallic materials is specific, since the current density tends to be inhomogeneous across the cross-section of the conductor and the skin effect tends to occur. However, the influence of this effect on the behaviour of the conductor can be optimized via the design and fabrication procedures. The study presents innovative design of an Al–Cu clad conductor, which is supposed to affect favourably the influence of the skin effect. The clad conductors of various diameters (20 mm, 15 mm, and 10 mm) were fabricated via rotary swaging at room temperature, and their electric characteristics were subsequently examined both experimentally and via numerical simulations. Structure analyses performed to document the effects of the swaging technology on the development of substructure and characteristic structural features were carried out by scanning electron microscopy (electron backscatter diffraction analyses), and transmission electron microscopy. The results showed that the design of the composite has a favourable effect on decreasing the power losses during alternating current transfer and that the substructure development affected favourably the electric resistance of the conductor. The highest electric resistance was measured for the composite conductor with the diameter of 20 mm (1.8% increase compared to electric resistance during transfer of direct current). This value then decreased to 0.6%, and 0.1% after swaging down to the diameters of 15 mm, and 10 mm; the 10 mm composite featured the finest grains, partially restored structure, and texture randomization compared to the 20 mm and 15 mm composites. Manufacturing of the clad composite via rotary swaging imparted advantageous combinations of both the electric and mechanical properties, as swaging also introduced increased microhardness. |
format | Online Article Text |
id | pubmed-8779058 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-87790582022-01-22 Influence of (Sub) Structure Development within Rotary Swaged Al–Cu Clad Conductors on Skin Effect during Transfer of Alternating Current Kunčická, Lenka Kocich, Radim Kačor, Petr Jambor, Michal Jopek, Miroslav Materials (Basel) Article The nature of alternating current transfer via metallic materials is specific, since the current density tends to be inhomogeneous across the cross-section of the conductor and the skin effect tends to occur. However, the influence of this effect on the behaviour of the conductor can be optimized via the design and fabrication procedures. The study presents innovative design of an Al–Cu clad conductor, which is supposed to affect favourably the influence of the skin effect. The clad conductors of various diameters (20 mm, 15 mm, and 10 mm) were fabricated via rotary swaging at room temperature, and their electric characteristics were subsequently examined both experimentally and via numerical simulations. Structure analyses performed to document the effects of the swaging technology on the development of substructure and characteristic structural features were carried out by scanning electron microscopy (electron backscatter diffraction analyses), and transmission electron microscopy. The results showed that the design of the composite has a favourable effect on decreasing the power losses during alternating current transfer and that the substructure development affected favourably the electric resistance of the conductor. The highest electric resistance was measured for the composite conductor with the diameter of 20 mm (1.8% increase compared to electric resistance during transfer of direct current). This value then decreased to 0.6%, and 0.1% after swaging down to the diameters of 15 mm, and 10 mm; the 10 mm composite featured the finest grains, partially restored structure, and texture randomization compared to the 20 mm and 15 mm composites. Manufacturing of the clad composite via rotary swaging imparted advantageous combinations of both the electric and mechanical properties, as swaging also introduced increased microhardness. MDPI 2022-01-15 /pmc/articles/PMC8779058/ /pubmed/35057368 http://dx.doi.org/10.3390/ma15020650 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Kunčická, Lenka Kocich, Radim Kačor, Petr Jambor, Michal Jopek, Miroslav Influence of (Sub) Structure Development within Rotary Swaged Al–Cu Clad Conductors on Skin Effect during Transfer of Alternating Current |
title | Influence of (Sub) Structure Development within Rotary Swaged Al–Cu Clad Conductors on Skin Effect during Transfer of Alternating Current |
title_full | Influence of (Sub) Structure Development within Rotary Swaged Al–Cu Clad Conductors on Skin Effect during Transfer of Alternating Current |
title_fullStr | Influence of (Sub) Structure Development within Rotary Swaged Al–Cu Clad Conductors on Skin Effect during Transfer of Alternating Current |
title_full_unstemmed | Influence of (Sub) Structure Development within Rotary Swaged Al–Cu Clad Conductors on Skin Effect during Transfer of Alternating Current |
title_short | Influence of (Sub) Structure Development within Rotary Swaged Al–Cu Clad Conductors on Skin Effect during Transfer of Alternating Current |
title_sort | influence of (sub) structure development within rotary swaged al–cu clad conductors on skin effect during transfer of alternating current |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8779058/ https://www.ncbi.nlm.nih.gov/pubmed/35057368 http://dx.doi.org/10.3390/ma15020650 |
work_keys_str_mv | AT kuncickalenka influenceofsubstructuredevelopmentwithinrotaryswagedalcucladconductorsonskineffectduringtransferofalternatingcurrent AT kocichradim influenceofsubstructuredevelopmentwithinrotaryswagedalcucladconductorsonskineffectduringtransferofalternatingcurrent AT kacorpetr influenceofsubstructuredevelopmentwithinrotaryswagedalcucladconductorsonskineffectduringtransferofalternatingcurrent AT jambormichal influenceofsubstructuredevelopmentwithinrotaryswagedalcucladconductorsonskineffectduringtransferofalternatingcurrent AT jopekmiroslav influenceofsubstructuredevelopmentwithinrotaryswagedalcucladconductorsonskineffectduringtransferofalternatingcurrent |