Smart Bio-Impedance-Based Sensor for Guiding Standard Needle Insertion

A venipuncture is the most common non-invasive medical procedure, and is frequently used with patients; however, a high probability of post-injection complications accompanies intravenous injection. The most common complication is a hematoma, which is associated with puncture of the uppermost and lo...

Descripción completa

Detalles Bibliográficos
Autores principales: Kudashov, Ivan, Shchukin, Sergey, Al-harosh, Mugeb, Shcherbachev, Andrew
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8779690/
https://www.ncbi.nlm.nih.gov/pubmed/35062626
http://dx.doi.org/10.3390/s22020665
_version_ 1784637639119339520
author Kudashov, Ivan
Shchukin, Sergey
Al-harosh, Mugeb
Shcherbachev, Andrew
author_facet Kudashov, Ivan
Shchukin, Sergey
Al-harosh, Mugeb
Shcherbachev, Andrew
author_sort Kudashov, Ivan
collection PubMed
description A venipuncture is the most common non-invasive medical procedure, and is frequently used with patients; however, a high probability of post-injection complications accompanies intravenous injection. The most common complication is a hematoma, which is associated with puncture of the uppermost and lowermost walls. To simplify and reduce complications of the venipuncture procedure, and as well as automation of this process, a device that can provide information of the needle tip position into patient’s tissues needs to be developed. This paper presents a peripheral vascular puncture control system based on electrical impedance measurements. A special electrode system was designed to achieve the maximum sensitivity for puncture identification using a traditional needle, which is usually used in clinical practice. An experimental study on subjects showed that the electrical impedance signal changed significantly once the standard needle entered the blood vessel. On basis of theoretical and experimental studies, a decision rule of puncture identification based on the analysis of amplitude-time parameters of experimental signals was proposed. The proposed method was tested on 15 test and 9 control samples, with the results showing that 97% accuracy was obtained.
format Online
Article
Text
id pubmed-8779690
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-87796902022-01-22 Smart Bio-Impedance-Based Sensor for Guiding Standard Needle Insertion Kudashov, Ivan Shchukin, Sergey Al-harosh, Mugeb Shcherbachev, Andrew Sensors (Basel) Article A venipuncture is the most common non-invasive medical procedure, and is frequently used with patients; however, a high probability of post-injection complications accompanies intravenous injection. The most common complication is a hematoma, which is associated with puncture of the uppermost and lowermost walls. To simplify and reduce complications of the venipuncture procedure, and as well as automation of this process, a device that can provide information of the needle tip position into patient’s tissues needs to be developed. This paper presents a peripheral vascular puncture control system based on electrical impedance measurements. A special electrode system was designed to achieve the maximum sensitivity for puncture identification using a traditional needle, which is usually used in clinical practice. An experimental study on subjects showed that the electrical impedance signal changed significantly once the standard needle entered the blood vessel. On basis of theoretical and experimental studies, a decision rule of puncture identification based on the analysis of amplitude-time parameters of experimental signals was proposed. The proposed method was tested on 15 test and 9 control samples, with the results showing that 97% accuracy was obtained. MDPI 2022-01-15 /pmc/articles/PMC8779690/ /pubmed/35062626 http://dx.doi.org/10.3390/s22020665 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kudashov, Ivan
Shchukin, Sergey
Al-harosh, Mugeb
Shcherbachev, Andrew
Smart Bio-Impedance-Based Sensor for Guiding Standard Needle Insertion
title Smart Bio-Impedance-Based Sensor for Guiding Standard Needle Insertion
title_full Smart Bio-Impedance-Based Sensor for Guiding Standard Needle Insertion
title_fullStr Smart Bio-Impedance-Based Sensor for Guiding Standard Needle Insertion
title_full_unstemmed Smart Bio-Impedance-Based Sensor for Guiding Standard Needle Insertion
title_short Smart Bio-Impedance-Based Sensor for Guiding Standard Needle Insertion
title_sort smart bio-impedance-based sensor for guiding standard needle insertion
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8779690/
https://www.ncbi.nlm.nih.gov/pubmed/35062626
http://dx.doi.org/10.3390/s22020665
work_keys_str_mv AT kudashovivan smartbioimpedancebasedsensorforguidingstandardneedleinsertion
AT shchukinsergey smartbioimpedancebasedsensorforguidingstandardneedleinsertion
AT alharoshmugeb smartbioimpedancebasedsensorforguidingstandardneedleinsertion
AT shcherbachevandrew smartbioimpedancebasedsensorforguidingstandardneedleinsertion