Fabrication of 2-D Capacitive Micromachined Ultrasonic Transducer (CMUT) Array through Silicon Wafer Bonding
Capacitive micromachined ultrasound transducers (CMUTs) have broad application prospects in medical imaging, flow monitoring, and nondestructive testing. CMUT arrays are limited by their fabrication process, which seriously restricts their further development and application. In this paper, a vacuum...
Autores principales: | , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8780229/ https://www.ncbi.nlm.nih.gov/pubmed/35056263 http://dx.doi.org/10.3390/mi13010099 |
_version_ | 1784637786205192192 |
---|---|
author | Wang, Ziyuan He, Changde Zhang, Wendong Li, Yifan Gao, Pengfei Meng, Yanan Zhang, Guojun Yang, Yuhua Wang, Renxin Cui, Jiangong Wang, Hongliang Zhang, Binzhen Ren, Yongfeng Zhen, Guoyong Jiao, Xinquan Zhang, Sai |
author_facet | Wang, Ziyuan He, Changde Zhang, Wendong Li, Yifan Gao, Pengfei Meng, Yanan Zhang, Guojun Yang, Yuhua Wang, Renxin Cui, Jiangong Wang, Hongliang Zhang, Binzhen Ren, Yongfeng Zhen, Guoyong Jiao, Xinquan Zhang, Sai |
author_sort | Wang, Ziyuan |
collection | PubMed |
description | Capacitive micromachined ultrasound transducers (CMUTs) have broad application prospects in medical imaging, flow monitoring, and nondestructive testing. CMUT arrays are limited by their fabrication process, which seriously restricts their further development and application. In this paper, a vacuum-sealed device for medical applications is introduced, which has the advantages of simple manufacturing process, no static friction, repeatability, and high reliability. The CMUT array suitable for medical imaging frequency band was fabricated by a silicon wafer bonding technology, and the adjacent array devices were isolated by an isolation slot, which was cut through the silicon film. The CMUT device fabricated following this process is a 4 × 16 array with a single element size of 1 mm × 1 mm. Device performance tests were conducted, where the center frequency of the transducer was 3.8 MHz, and the 6 dB fractional bandwidth was 110%. The static capacitance (29.4 pF) and center frequency (3.78 MHz) of each element of the array were tested, and the results revealed that the array has good consistency. Moreover, the transmitting and receiving performance of the transducer was evaluated by acoustic tests, and the receiving sensitivity was −211 dB @ 3 MHz, −213 dB @ 4 MHz. Finally, reflection imaging was performed using the array, which provides certain technical support for the research of two-dimensional CMUT arrays in the field of 3D ultrasound imaging. |
format | Online Article Text |
id | pubmed-8780229 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-87802292022-01-22 Fabrication of 2-D Capacitive Micromachined Ultrasonic Transducer (CMUT) Array through Silicon Wafer Bonding Wang, Ziyuan He, Changde Zhang, Wendong Li, Yifan Gao, Pengfei Meng, Yanan Zhang, Guojun Yang, Yuhua Wang, Renxin Cui, Jiangong Wang, Hongliang Zhang, Binzhen Ren, Yongfeng Zhen, Guoyong Jiao, Xinquan Zhang, Sai Micromachines (Basel) Article Capacitive micromachined ultrasound transducers (CMUTs) have broad application prospects in medical imaging, flow monitoring, and nondestructive testing. CMUT arrays are limited by their fabrication process, which seriously restricts their further development and application. In this paper, a vacuum-sealed device for medical applications is introduced, which has the advantages of simple manufacturing process, no static friction, repeatability, and high reliability. The CMUT array suitable for medical imaging frequency band was fabricated by a silicon wafer bonding technology, and the adjacent array devices were isolated by an isolation slot, which was cut through the silicon film. The CMUT device fabricated following this process is a 4 × 16 array with a single element size of 1 mm × 1 mm. Device performance tests were conducted, where the center frequency of the transducer was 3.8 MHz, and the 6 dB fractional bandwidth was 110%. The static capacitance (29.4 pF) and center frequency (3.78 MHz) of each element of the array were tested, and the results revealed that the array has good consistency. Moreover, the transmitting and receiving performance of the transducer was evaluated by acoustic tests, and the receiving sensitivity was −211 dB @ 3 MHz, −213 dB @ 4 MHz. Finally, reflection imaging was performed using the array, which provides certain technical support for the research of two-dimensional CMUT arrays in the field of 3D ultrasound imaging. MDPI 2022-01-08 /pmc/articles/PMC8780229/ /pubmed/35056263 http://dx.doi.org/10.3390/mi13010099 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Wang, Ziyuan He, Changde Zhang, Wendong Li, Yifan Gao, Pengfei Meng, Yanan Zhang, Guojun Yang, Yuhua Wang, Renxin Cui, Jiangong Wang, Hongliang Zhang, Binzhen Ren, Yongfeng Zhen, Guoyong Jiao, Xinquan Zhang, Sai Fabrication of 2-D Capacitive Micromachined Ultrasonic Transducer (CMUT) Array through Silicon Wafer Bonding |
title | Fabrication of 2-D Capacitive Micromachined Ultrasonic Transducer (CMUT) Array through Silicon Wafer Bonding |
title_full | Fabrication of 2-D Capacitive Micromachined Ultrasonic Transducer (CMUT) Array through Silicon Wafer Bonding |
title_fullStr | Fabrication of 2-D Capacitive Micromachined Ultrasonic Transducer (CMUT) Array through Silicon Wafer Bonding |
title_full_unstemmed | Fabrication of 2-D Capacitive Micromachined Ultrasonic Transducer (CMUT) Array through Silicon Wafer Bonding |
title_short | Fabrication of 2-D Capacitive Micromachined Ultrasonic Transducer (CMUT) Array through Silicon Wafer Bonding |
title_sort | fabrication of 2-d capacitive micromachined ultrasonic transducer (cmut) array through silicon wafer bonding |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8780229/ https://www.ncbi.nlm.nih.gov/pubmed/35056263 http://dx.doi.org/10.3390/mi13010099 |
work_keys_str_mv | AT wangziyuan fabricationof2dcapacitivemicromachinedultrasonictransducercmutarraythroughsiliconwaferbonding AT hechangde fabricationof2dcapacitivemicromachinedultrasonictransducercmutarraythroughsiliconwaferbonding AT zhangwendong fabricationof2dcapacitivemicromachinedultrasonictransducercmutarraythroughsiliconwaferbonding AT liyifan fabricationof2dcapacitivemicromachinedultrasonictransducercmutarraythroughsiliconwaferbonding AT gaopengfei fabricationof2dcapacitivemicromachinedultrasonictransducercmutarraythroughsiliconwaferbonding AT mengyanan fabricationof2dcapacitivemicromachinedultrasonictransducercmutarraythroughsiliconwaferbonding AT zhangguojun fabricationof2dcapacitivemicromachinedultrasonictransducercmutarraythroughsiliconwaferbonding AT yangyuhua fabricationof2dcapacitivemicromachinedultrasonictransducercmutarraythroughsiliconwaferbonding AT wangrenxin fabricationof2dcapacitivemicromachinedultrasonictransducercmutarraythroughsiliconwaferbonding AT cuijiangong fabricationof2dcapacitivemicromachinedultrasonictransducercmutarraythroughsiliconwaferbonding AT wanghongliang fabricationof2dcapacitivemicromachinedultrasonictransducercmutarraythroughsiliconwaferbonding AT zhangbinzhen fabricationof2dcapacitivemicromachinedultrasonictransducercmutarraythroughsiliconwaferbonding AT renyongfeng fabricationof2dcapacitivemicromachinedultrasonictransducercmutarraythroughsiliconwaferbonding AT zhenguoyong fabricationof2dcapacitivemicromachinedultrasonictransducercmutarraythroughsiliconwaferbonding AT jiaoxinquan fabricationof2dcapacitivemicromachinedultrasonictransducercmutarraythroughsiliconwaferbonding AT zhangsai fabricationof2dcapacitivemicromachinedultrasonictransducercmutarraythroughsiliconwaferbonding |