Cargando…

Designing Sensitivity: A Comparative Analysis of Microelectrode Topologies for Electrochemical Oxygen Sensing in Biomedical Applications

The monitoring of dissolved oxygen is a key parameter in many fields, namely the treatment and monitoring of various cerebral traumas. Leveraging existing manufacturing techniques, electrochemical sensors hold the potential for compact, simple, and scalable dissolved oxygen sensors. Past studies hav...

Descripción completa

Detalles Bibliográficos
Autores principales: Bacheschi, Daniel T., Strittmatter, Evan Z., Sawtelle, Sonya, Nami, Mohsen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8780433/
https://www.ncbi.nlm.nih.gov/pubmed/35056306
http://dx.doi.org/10.3390/mi13010141
_version_ 1784637836823101440
author Bacheschi, Daniel T.
Strittmatter, Evan Z.
Sawtelle, Sonya
Nami, Mohsen
author_facet Bacheschi, Daniel T.
Strittmatter, Evan Z.
Sawtelle, Sonya
Nami, Mohsen
author_sort Bacheschi, Daniel T.
collection PubMed
description The monitoring of dissolved oxygen is a key parameter in many fields, namely the treatment and monitoring of various cerebral traumas. Leveraging existing manufacturing techniques, electrochemical sensors hold the potential for compact, simple, and scalable dissolved oxygen sensors. Past studies have focused on the general design of such sensors, but a comparative study on the impact of microelectrode geometries for cerebral applications has been forthcoming. We present here the results of a characterization study conducted across solid-state sensors with varying microelectrode geometries. The electrode structures were covered with a Nafion membrane and included variations of the classic interdigitated microelectrode array in addition to a circular microelectrode array variation. Voltage sweeps were conducted while monitoring the devices’ sensing current responses across a 50.3 mmHg change in dissolved oxygen within a deionized aqueous solution. Half of the devices were identified as ultramicroelectrode designs that presented a greater dependence on electrode spacing and topology. The ultramicroelectrode-style (UME) interdigitated electrode (IDE) topology presented the greatest signal response at 25.24 nA/mmHg, an approximate eight-fold improvement in sensitivity from a non-UME variation with a sensitivity of 2.98 nA/mmHg. The design presented a linear response from 8.3 mmHg to 58.6 mmHg with r(2) = 0.9743. The sensitivity improvement was attributed to the ultramicroelectrode structure’s amplifying diffusive feedback, which was enabled by the IDE topology and short electrode spacings.
format Online
Article
Text
id pubmed-8780433
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-87804332022-01-22 Designing Sensitivity: A Comparative Analysis of Microelectrode Topologies for Electrochemical Oxygen Sensing in Biomedical Applications Bacheschi, Daniel T. Strittmatter, Evan Z. Sawtelle, Sonya Nami, Mohsen Micromachines (Basel) Article The monitoring of dissolved oxygen is a key parameter in many fields, namely the treatment and monitoring of various cerebral traumas. Leveraging existing manufacturing techniques, electrochemical sensors hold the potential for compact, simple, and scalable dissolved oxygen sensors. Past studies have focused on the general design of such sensors, but a comparative study on the impact of microelectrode geometries for cerebral applications has been forthcoming. We present here the results of a characterization study conducted across solid-state sensors with varying microelectrode geometries. The electrode structures were covered with a Nafion membrane and included variations of the classic interdigitated microelectrode array in addition to a circular microelectrode array variation. Voltage sweeps were conducted while monitoring the devices’ sensing current responses across a 50.3 mmHg change in dissolved oxygen within a deionized aqueous solution. Half of the devices were identified as ultramicroelectrode designs that presented a greater dependence on electrode spacing and topology. The ultramicroelectrode-style (UME) interdigitated electrode (IDE) topology presented the greatest signal response at 25.24 nA/mmHg, an approximate eight-fold improvement in sensitivity from a non-UME variation with a sensitivity of 2.98 nA/mmHg. The design presented a linear response from 8.3 mmHg to 58.6 mmHg with r(2) = 0.9743. The sensitivity improvement was attributed to the ultramicroelectrode structure’s amplifying diffusive feedback, which was enabled by the IDE topology and short electrode spacings. MDPI 2022-01-17 /pmc/articles/PMC8780433/ /pubmed/35056306 http://dx.doi.org/10.3390/mi13010141 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Bacheschi, Daniel T.
Strittmatter, Evan Z.
Sawtelle, Sonya
Nami, Mohsen
Designing Sensitivity: A Comparative Analysis of Microelectrode Topologies for Electrochemical Oxygen Sensing in Biomedical Applications
title Designing Sensitivity: A Comparative Analysis of Microelectrode Topologies for Electrochemical Oxygen Sensing in Biomedical Applications
title_full Designing Sensitivity: A Comparative Analysis of Microelectrode Topologies for Electrochemical Oxygen Sensing in Biomedical Applications
title_fullStr Designing Sensitivity: A Comparative Analysis of Microelectrode Topologies for Electrochemical Oxygen Sensing in Biomedical Applications
title_full_unstemmed Designing Sensitivity: A Comparative Analysis of Microelectrode Topologies for Electrochemical Oxygen Sensing in Biomedical Applications
title_short Designing Sensitivity: A Comparative Analysis of Microelectrode Topologies for Electrochemical Oxygen Sensing in Biomedical Applications
title_sort designing sensitivity: a comparative analysis of microelectrode topologies for electrochemical oxygen sensing in biomedical applications
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8780433/
https://www.ncbi.nlm.nih.gov/pubmed/35056306
http://dx.doi.org/10.3390/mi13010141
work_keys_str_mv AT bacheschidanielt designingsensitivityacomparativeanalysisofmicroelectrodetopologiesforelectrochemicaloxygensensinginbiomedicalapplications
AT strittmatterevanz designingsensitivityacomparativeanalysisofmicroelectrodetopologiesforelectrochemicaloxygensensinginbiomedicalapplications
AT sawtellesonya designingsensitivityacomparativeanalysisofmicroelectrodetopologiesforelectrochemicaloxygensensinginbiomedicalapplications
AT namimohsen designingsensitivityacomparativeanalysisofmicroelectrodetopologiesforelectrochemicaloxygensensinginbiomedicalapplications