Cargando…
Designing Sensitivity: A Comparative Analysis of Microelectrode Topologies for Electrochemical Oxygen Sensing in Biomedical Applications
The monitoring of dissolved oxygen is a key parameter in many fields, namely the treatment and monitoring of various cerebral traumas. Leveraging existing manufacturing techniques, electrochemical sensors hold the potential for compact, simple, and scalable dissolved oxygen sensors. Past studies hav...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8780433/ https://www.ncbi.nlm.nih.gov/pubmed/35056306 http://dx.doi.org/10.3390/mi13010141 |
_version_ | 1784637836823101440 |
---|---|
author | Bacheschi, Daniel T. Strittmatter, Evan Z. Sawtelle, Sonya Nami, Mohsen |
author_facet | Bacheschi, Daniel T. Strittmatter, Evan Z. Sawtelle, Sonya Nami, Mohsen |
author_sort | Bacheschi, Daniel T. |
collection | PubMed |
description | The monitoring of dissolved oxygen is a key parameter in many fields, namely the treatment and monitoring of various cerebral traumas. Leveraging existing manufacturing techniques, electrochemical sensors hold the potential for compact, simple, and scalable dissolved oxygen sensors. Past studies have focused on the general design of such sensors, but a comparative study on the impact of microelectrode geometries for cerebral applications has been forthcoming. We present here the results of a characterization study conducted across solid-state sensors with varying microelectrode geometries. The electrode structures were covered with a Nafion membrane and included variations of the classic interdigitated microelectrode array in addition to a circular microelectrode array variation. Voltage sweeps were conducted while monitoring the devices’ sensing current responses across a 50.3 mmHg change in dissolved oxygen within a deionized aqueous solution. Half of the devices were identified as ultramicroelectrode designs that presented a greater dependence on electrode spacing and topology. The ultramicroelectrode-style (UME) interdigitated electrode (IDE) topology presented the greatest signal response at 25.24 nA/mmHg, an approximate eight-fold improvement in sensitivity from a non-UME variation with a sensitivity of 2.98 nA/mmHg. The design presented a linear response from 8.3 mmHg to 58.6 mmHg with r(2) = 0.9743. The sensitivity improvement was attributed to the ultramicroelectrode structure’s amplifying diffusive feedback, which was enabled by the IDE topology and short electrode spacings. |
format | Online Article Text |
id | pubmed-8780433 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-87804332022-01-22 Designing Sensitivity: A Comparative Analysis of Microelectrode Topologies for Electrochemical Oxygen Sensing in Biomedical Applications Bacheschi, Daniel T. Strittmatter, Evan Z. Sawtelle, Sonya Nami, Mohsen Micromachines (Basel) Article The monitoring of dissolved oxygen is a key parameter in many fields, namely the treatment and monitoring of various cerebral traumas. Leveraging existing manufacturing techniques, electrochemical sensors hold the potential for compact, simple, and scalable dissolved oxygen sensors. Past studies have focused on the general design of such sensors, but a comparative study on the impact of microelectrode geometries for cerebral applications has been forthcoming. We present here the results of a characterization study conducted across solid-state sensors with varying microelectrode geometries. The electrode structures were covered with a Nafion membrane and included variations of the classic interdigitated microelectrode array in addition to a circular microelectrode array variation. Voltage sweeps were conducted while monitoring the devices’ sensing current responses across a 50.3 mmHg change in dissolved oxygen within a deionized aqueous solution. Half of the devices were identified as ultramicroelectrode designs that presented a greater dependence on electrode spacing and topology. The ultramicroelectrode-style (UME) interdigitated electrode (IDE) topology presented the greatest signal response at 25.24 nA/mmHg, an approximate eight-fold improvement in sensitivity from a non-UME variation with a sensitivity of 2.98 nA/mmHg. The design presented a linear response from 8.3 mmHg to 58.6 mmHg with r(2) = 0.9743. The sensitivity improvement was attributed to the ultramicroelectrode structure’s amplifying diffusive feedback, which was enabled by the IDE topology and short electrode spacings. MDPI 2022-01-17 /pmc/articles/PMC8780433/ /pubmed/35056306 http://dx.doi.org/10.3390/mi13010141 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Bacheschi, Daniel T. Strittmatter, Evan Z. Sawtelle, Sonya Nami, Mohsen Designing Sensitivity: A Comparative Analysis of Microelectrode Topologies for Electrochemical Oxygen Sensing in Biomedical Applications |
title | Designing Sensitivity: A Comparative Analysis of Microelectrode Topologies for Electrochemical Oxygen Sensing in Biomedical Applications |
title_full | Designing Sensitivity: A Comparative Analysis of Microelectrode Topologies for Electrochemical Oxygen Sensing in Biomedical Applications |
title_fullStr | Designing Sensitivity: A Comparative Analysis of Microelectrode Topologies for Electrochemical Oxygen Sensing in Biomedical Applications |
title_full_unstemmed | Designing Sensitivity: A Comparative Analysis of Microelectrode Topologies for Electrochemical Oxygen Sensing in Biomedical Applications |
title_short | Designing Sensitivity: A Comparative Analysis of Microelectrode Topologies for Electrochemical Oxygen Sensing in Biomedical Applications |
title_sort | designing sensitivity: a comparative analysis of microelectrode topologies for electrochemical oxygen sensing in biomedical applications |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8780433/ https://www.ncbi.nlm.nih.gov/pubmed/35056306 http://dx.doi.org/10.3390/mi13010141 |
work_keys_str_mv | AT bacheschidanielt designingsensitivityacomparativeanalysisofmicroelectrodetopologiesforelectrochemicaloxygensensinginbiomedicalapplications AT strittmatterevanz designingsensitivityacomparativeanalysisofmicroelectrodetopologiesforelectrochemicaloxygensensinginbiomedicalapplications AT sawtellesonya designingsensitivityacomparativeanalysisofmicroelectrodetopologiesforelectrochemicaloxygensensinginbiomedicalapplications AT namimohsen designingsensitivityacomparativeanalysisofmicroelectrodetopologiesforelectrochemicaloxygensensinginbiomedicalapplications |