Cargando…
Hybrid PWM Techniques for a DCM-232 Three-Phase Transformerless Inverter with Reduced Leakage Ground Current
Pulse Width Modulation (PWM) strategies are crucial for controlling DC–AC power converters. In particular, transformerless inverters require specific PWM techniques to improve efficiency and to deal with leakage ground current issues. In this paper, three hybrid PWM methods are proposed for a DCM-23...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8780749/ https://www.ncbi.nlm.nih.gov/pubmed/35056201 http://dx.doi.org/10.3390/mi13010036 |
_version_ | 1784637920949305344 |
---|---|
author | Vazquez-Guzman, Gerardo Martinez-Rodriguez, Panfilo R. Sosa-Zuñiga, Jose M. Aztatzi-Pluma, Dalyndha Langarica-Cordoba, Diego Saldivar, Belem Martínez-Méndez, Rigoberto |
author_facet | Vazquez-Guzman, Gerardo Martinez-Rodriguez, Panfilo R. Sosa-Zuñiga, Jose M. Aztatzi-Pluma, Dalyndha Langarica-Cordoba, Diego Saldivar, Belem Martínez-Méndez, Rigoberto |
author_sort | Vazquez-Guzman, Gerardo |
collection | PubMed |
description | Pulse Width Modulation (PWM) strategies are crucial for controlling DC–AC power converters. In particular, transformerless inverters require specific PWM techniques to improve efficiency and to deal with leakage ground current issues. In this paper, three hybrid PWM methods are proposed for a DCM-232 three-phase topology. These methods are based on the concepts of carrier-based PWM and space vector modulation. Calculations of time intervals for active and null vectors are performed in a conventional way, and the resulting waveforms are compared with a carrier signal. The digital signals obtained are processed using Boolean functions, generating ten signals to control the DCM-232 three-phase inverter. The performance of the three proposed PWM methods is evaluated considering the reduction in leakage ground current and efficiency. The proposed modulation techniques have relevant performances complying with international standards, which make them suitable for transformerless three-phase photovoltaic (PV) inverter markets. To validate the proposed hybrid PWM strategies, numerical simulations and experimental tests were performed. |
format | Online Article Text |
id | pubmed-8780749 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-87807492022-01-22 Hybrid PWM Techniques for a DCM-232 Three-Phase Transformerless Inverter with Reduced Leakage Ground Current Vazquez-Guzman, Gerardo Martinez-Rodriguez, Panfilo R. Sosa-Zuñiga, Jose M. Aztatzi-Pluma, Dalyndha Langarica-Cordoba, Diego Saldivar, Belem Martínez-Méndez, Rigoberto Micromachines (Basel) Article Pulse Width Modulation (PWM) strategies are crucial for controlling DC–AC power converters. In particular, transformerless inverters require specific PWM techniques to improve efficiency and to deal with leakage ground current issues. In this paper, three hybrid PWM methods are proposed for a DCM-232 three-phase topology. These methods are based on the concepts of carrier-based PWM and space vector modulation. Calculations of time intervals for active and null vectors are performed in a conventional way, and the resulting waveforms are compared with a carrier signal. The digital signals obtained are processed using Boolean functions, generating ten signals to control the DCM-232 three-phase inverter. The performance of the three proposed PWM methods is evaluated considering the reduction in leakage ground current and efficiency. The proposed modulation techniques have relevant performances complying with international standards, which make them suitable for transformerless three-phase photovoltaic (PV) inverter markets. To validate the proposed hybrid PWM strategies, numerical simulations and experimental tests were performed. MDPI 2021-12-28 /pmc/articles/PMC8780749/ /pubmed/35056201 http://dx.doi.org/10.3390/mi13010036 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Vazquez-Guzman, Gerardo Martinez-Rodriguez, Panfilo R. Sosa-Zuñiga, Jose M. Aztatzi-Pluma, Dalyndha Langarica-Cordoba, Diego Saldivar, Belem Martínez-Méndez, Rigoberto Hybrid PWM Techniques for a DCM-232 Three-Phase Transformerless Inverter with Reduced Leakage Ground Current |
title | Hybrid PWM Techniques for a DCM-232 Three-Phase Transformerless Inverter with Reduced Leakage Ground Current |
title_full | Hybrid PWM Techniques for a DCM-232 Three-Phase Transformerless Inverter with Reduced Leakage Ground Current |
title_fullStr | Hybrid PWM Techniques for a DCM-232 Three-Phase Transformerless Inverter with Reduced Leakage Ground Current |
title_full_unstemmed | Hybrid PWM Techniques for a DCM-232 Three-Phase Transformerless Inverter with Reduced Leakage Ground Current |
title_short | Hybrid PWM Techniques for a DCM-232 Three-Phase Transformerless Inverter with Reduced Leakage Ground Current |
title_sort | hybrid pwm techniques for a dcm-232 three-phase transformerless inverter with reduced leakage ground current |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8780749/ https://www.ncbi.nlm.nih.gov/pubmed/35056201 http://dx.doi.org/10.3390/mi13010036 |
work_keys_str_mv | AT vazquezguzmangerardo hybridpwmtechniquesforadcm232threephasetransformerlessinverterwithreducedleakagegroundcurrent AT martinezrodriguezpanfilor hybridpwmtechniquesforadcm232threephasetransformerlessinverterwithreducedleakagegroundcurrent AT sosazunigajosem hybridpwmtechniquesforadcm232threephasetransformerlessinverterwithreducedleakagegroundcurrent AT aztatziplumadalyndha hybridpwmtechniquesforadcm232threephasetransformerlessinverterwithreducedleakagegroundcurrent AT langaricacordobadiego hybridpwmtechniquesforadcm232threephasetransformerlessinverterwithreducedleakagegroundcurrent AT saldivarbelem hybridpwmtechniquesforadcm232threephasetransformerlessinverterwithreducedleakagegroundcurrent AT martinezmendezrigoberto hybridpwmtechniquesforadcm232threephasetransformerlessinverterwithreducedleakagegroundcurrent |