Cargando…
Determination of Parabens, Bisphenol A and Its Analogs, Triclosan, and Benzophenone-3 Levels in Human Urine by Isotope-Dilution-UPLC-MS/MS Method Followed by Supported Liquid Extraction
The development of a rapid analytical approach for determining levels of antibacterial agents, plasticizers, and ultraviolet filters in biosamples is crucial for individual exposure assessment. We developed an analytical method to determine the levels of four parabens—bisphenols A (BPA) and its anal...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8781104/ https://www.ncbi.nlm.nih.gov/pubmed/35051063 http://dx.doi.org/10.3390/toxics10010021 |
_version_ | 1784638009371525120 |
---|---|
author | Chen, Hsin-Chang Chang, Jung-Wei Sun, Yi-Chen Chang, Wan-Ting Huang, Po-Chin |
author_facet | Chen, Hsin-Chang Chang, Jung-Wei Sun, Yi-Chen Chang, Wan-Ting Huang, Po-Chin |
author_sort | Chen, Hsin-Chang |
collection | PubMed |
description | The development of a rapid analytical approach for determining levels of antibacterial agents, plasticizers, and ultraviolet filters in biosamples is crucial for individual exposure assessment. We developed an analytical method to determine the levels of four parabens—bisphenols A (BPA) and its analogs, triclosan (TCS), triclocarban, and benzophenone-3 (BP-3)—in human urine. We further measured the levels of these chemicals in children and adolescents. We used a supported liquid extraction (SLE) technique coupled with an isotope-dilution ultraperformance liquid chromatography-tandem mass spectrometry (ID-UPLC-MS/MS) method to assess the detection performance for these chemicals. Forty-one urine samples from 13 children and 28 adolescents were assessed to demonstrate the capability and feasibility of our method. An acceptable recovery (75.6–102.4%) and matrix effect (precision < 14.2%) in the three-level spiked artificial urine samples were achieved, and good performance of the validated ID-UPLC-MS/MS method regarding linearity, limits of detection, and quantitation was achieved. The within-run and between-run accuracy and precision also demonstrated the sensitivity and stability of this analytical method, applied after SLE. We concluded that the ID-UPLC-MS/MS method with SLE pretreatment is a valuable analytical method for the investigation of urinary antibacterial agents, plasticizers, and ultraviolet filters in humans, useful for human biomonitoring. |
format | Online Article Text |
id | pubmed-8781104 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-87811042022-01-22 Determination of Parabens, Bisphenol A and Its Analogs, Triclosan, and Benzophenone-3 Levels in Human Urine by Isotope-Dilution-UPLC-MS/MS Method Followed by Supported Liquid Extraction Chen, Hsin-Chang Chang, Jung-Wei Sun, Yi-Chen Chang, Wan-Ting Huang, Po-Chin Toxics Article The development of a rapid analytical approach for determining levels of antibacterial agents, plasticizers, and ultraviolet filters in biosamples is crucial for individual exposure assessment. We developed an analytical method to determine the levels of four parabens—bisphenols A (BPA) and its analogs, triclosan (TCS), triclocarban, and benzophenone-3 (BP-3)—in human urine. We further measured the levels of these chemicals in children and adolescents. We used a supported liquid extraction (SLE) technique coupled with an isotope-dilution ultraperformance liquid chromatography-tandem mass spectrometry (ID-UPLC-MS/MS) method to assess the detection performance for these chemicals. Forty-one urine samples from 13 children and 28 adolescents were assessed to demonstrate the capability and feasibility of our method. An acceptable recovery (75.6–102.4%) and matrix effect (precision < 14.2%) in the three-level spiked artificial urine samples were achieved, and good performance of the validated ID-UPLC-MS/MS method regarding linearity, limits of detection, and quantitation was achieved. The within-run and between-run accuracy and precision also demonstrated the sensitivity and stability of this analytical method, applied after SLE. We concluded that the ID-UPLC-MS/MS method with SLE pretreatment is a valuable analytical method for the investigation of urinary antibacterial agents, plasticizers, and ultraviolet filters in humans, useful for human biomonitoring. MDPI 2022-01-06 /pmc/articles/PMC8781104/ /pubmed/35051063 http://dx.doi.org/10.3390/toxics10010021 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Chen, Hsin-Chang Chang, Jung-Wei Sun, Yi-Chen Chang, Wan-Ting Huang, Po-Chin Determination of Parabens, Bisphenol A and Its Analogs, Triclosan, and Benzophenone-3 Levels in Human Urine by Isotope-Dilution-UPLC-MS/MS Method Followed by Supported Liquid Extraction |
title | Determination of Parabens, Bisphenol A and Its Analogs, Triclosan, and Benzophenone-3 Levels in Human Urine by Isotope-Dilution-UPLC-MS/MS Method Followed by Supported Liquid Extraction |
title_full | Determination of Parabens, Bisphenol A and Its Analogs, Triclosan, and Benzophenone-3 Levels in Human Urine by Isotope-Dilution-UPLC-MS/MS Method Followed by Supported Liquid Extraction |
title_fullStr | Determination of Parabens, Bisphenol A and Its Analogs, Triclosan, and Benzophenone-3 Levels in Human Urine by Isotope-Dilution-UPLC-MS/MS Method Followed by Supported Liquid Extraction |
title_full_unstemmed | Determination of Parabens, Bisphenol A and Its Analogs, Triclosan, and Benzophenone-3 Levels in Human Urine by Isotope-Dilution-UPLC-MS/MS Method Followed by Supported Liquid Extraction |
title_short | Determination of Parabens, Bisphenol A and Its Analogs, Triclosan, and Benzophenone-3 Levels in Human Urine by Isotope-Dilution-UPLC-MS/MS Method Followed by Supported Liquid Extraction |
title_sort | determination of parabens, bisphenol a and its analogs, triclosan, and benzophenone-3 levels in human urine by isotope-dilution-uplc-ms/ms method followed by supported liquid extraction |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8781104/ https://www.ncbi.nlm.nih.gov/pubmed/35051063 http://dx.doi.org/10.3390/toxics10010021 |
work_keys_str_mv | AT chenhsinchang determinationofparabensbisphenolaanditsanalogstriclosanandbenzophenone3levelsinhumanurinebyisotopedilutionuplcmsmsmethodfollowedbysupportedliquidextraction AT changjungwei determinationofparabensbisphenolaanditsanalogstriclosanandbenzophenone3levelsinhumanurinebyisotopedilutionuplcmsmsmethodfollowedbysupportedliquidextraction AT sunyichen determinationofparabensbisphenolaanditsanalogstriclosanandbenzophenone3levelsinhumanurinebyisotopedilutionuplcmsmsmethodfollowedbysupportedliquidextraction AT changwanting determinationofparabensbisphenolaanditsanalogstriclosanandbenzophenone3levelsinhumanurinebyisotopedilutionuplcmsmsmethodfollowedbysupportedliquidextraction AT huangpochin determinationofparabensbisphenolaanditsanalogstriclosanandbenzophenone3levelsinhumanurinebyisotopedilutionuplcmsmsmethodfollowedbysupportedliquidextraction |