Cargando…

Determination of Parabens, Bisphenol A and Its Analogs, Triclosan, and Benzophenone-3 Levels in Human Urine by Isotope-Dilution-UPLC-MS/MS Method Followed by Supported Liquid Extraction

The development of a rapid analytical approach for determining levels of antibacterial agents, plasticizers, and ultraviolet filters in biosamples is crucial for individual exposure assessment. We developed an analytical method to determine the levels of four parabens—bisphenols A (BPA) and its anal...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Hsin-Chang, Chang, Jung-Wei, Sun, Yi-Chen, Chang, Wan-Ting, Huang, Po-Chin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8781104/
https://www.ncbi.nlm.nih.gov/pubmed/35051063
http://dx.doi.org/10.3390/toxics10010021
_version_ 1784638009371525120
author Chen, Hsin-Chang
Chang, Jung-Wei
Sun, Yi-Chen
Chang, Wan-Ting
Huang, Po-Chin
author_facet Chen, Hsin-Chang
Chang, Jung-Wei
Sun, Yi-Chen
Chang, Wan-Ting
Huang, Po-Chin
author_sort Chen, Hsin-Chang
collection PubMed
description The development of a rapid analytical approach for determining levels of antibacterial agents, plasticizers, and ultraviolet filters in biosamples is crucial for individual exposure assessment. We developed an analytical method to determine the levels of four parabens—bisphenols A (BPA) and its analogs, triclosan (TCS), triclocarban, and benzophenone-3 (BP-3)—in human urine. We further measured the levels of these chemicals in children and adolescents. We used a supported liquid extraction (SLE) technique coupled with an isotope-dilution ultraperformance liquid chromatography-tandem mass spectrometry (ID-UPLC-MS/MS) method to assess the detection performance for these chemicals. Forty-one urine samples from 13 children and 28 adolescents were assessed to demonstrate the capability and feasibility of our method. An acceptable recovery (75.6–102.4%) and matrix effect (precision < 14.2%) in the three-level spiked artificial urine samples were achieved, and good performance of the validated ID-UPLC-MS/MS method regarding linearity, limits of detection, and quantitation was achieved. The within-run and between-run accuracy and precision also demonstrated the sensitivity and stability of this analytical method, applied after SLE. We concluded that the ID-UPLC-MS/MS method with SLE pretreatment is a valuable analytical method for the investigation of urinary antibacterial agents, plasticizers, and ultraviolet filters in humans, useful for human biomonitoring.
format Online
Article
Text
id pubmed-8781104
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-87811042022-01-22 Determination of Parabens, Bisphenol A and Its Analogs, Triclosan, and Benzophenone-3 Levels in Human Urine by Isotope-Dilution-UPLC-MS/MS Method Followed by Supported Liquid Extraction Chen, Hsin-Chang Chang, Jung-Wei Sun, Yi-Chen Chang, Wan-Ting Huang, Po-Chin Toxics Article The development of a rapid analytical approach for determining levels of antibacterial agents, plasticizers, and ultraviolet filters in biosamples is crucial for individual exposure assessment. We developed an analytical method to determine the levels of four parabens—bisphenols A (BPA) and its analogs, triclosan (TCS), triclocarban, and benzophenone-3 (BP-3)—in human urine. We further measured the levels of these chemicals in children and adolescents. We used a supported liquid extraction (SLE) technique coupled with an isotope-dilution ultraperformance liquid chromatography-tandem mass spectrometry (ID-UPLC-MS/MS) method to assess the detection performance for these chemicals. Forty-one urine samples from 13 children and 28 adolescents were assessed to demonstrate the capability and feasibility of our method. An acceptable recovery (75.6–102.4%) and matrix effect (precision < 14.2%) in the three-level spiked artificial urine samples were achieved, and good performance of the validated ID-UPLC-MS/MS method regarding linearity, limits of detection, and quantitation was achieved. The within-run and between-run accuracy and precision also demonstrated the sensitivity and stability of this analytical method, applied after SLE. We concluded that the ID-UPLC-MS/MS method with SLE pretreatment is a valuable analytical method for the investigation of urinary antibacterial agents, plasticizers, and ultraviolet filters in humans, useful for human biomonitoring. MDPI 2022-01-06 /pmc/articles/PMC8781104/ /pubmed/35051063 http://dx.doi.org/10.3390/toxics10010021 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Chen, Hsin-Chang
Chang, Jung-Wei
Sun, Yi-Chen
Chang, Wan-Ting
Huang, Po-Chin
Determination of Parabens, Bisphenol A and Its Analogs, Triclosan, and Benzophenone-3 Levels in Human Urine by Isotope-Dilution-UPLC-MS/MS Method Followed by Supported Liquid Extraction
title Determination of Parabens, Bisphenol A and Its Analogs, Triclosan, and Benzophenone-3 Levels in Human Urine by Isotope-Dilution-UPLC-MS/MS Method Followed by Supported Liquid Extraction
title_full Determination of Parabens, Bisphenol A and Its Analogs, Triclosan, and Benzophenone-3 Levels in Human Urine by Isotope-Dilution-UPLC-MS/MS Method Followed by Supported Liquid Extraction
title_fullStr Determination of Parabens, Bisphenol A and Its Analogs, Triclosan, and Benzophenone-3 Levels in Human Urine by Isotope-Dilution-UPLC-MS/MS Method Followed by Supported Liquid Extraction
title_full_unstemmed Determination of Parabens, Bisphenol A and Its Analogs, Triclosan, and Benzophenone-3 Levels in Human Urine by Isotope-Dilution-UPLC-MS/MS Method Followed by Supported Liquid Extraction
title_short Determination of Parabens, Bisphenol A and Its Analogs, Triclosan, and Benzophenone-3 Levels in Human Urine by Isotope-Dilution-UPLC-MS/MS Method Followed by Supported Liquid Extraction
title_sort determination of parabens, bisphenol a and its analogs, triclosan, and benzophenone-3 levels in human urine by isotope-dilution-uplc-ms/ms method followed by supported liquid extraction
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8781104/
https://www.ncbi.nlm.nih.gov/pubmed/35051063
http://dx.doi.org/10.3390/toxics10010021
work_keys_str_mv AT chenhsinchang determinationofparabensbisphenolaanditsanalogstriclosanandbenzophenone3levelsinhumanurinebyisotopedilutionuplcmsmsmethodfollowedbysupportedliquidextraction
AT changjungwei determinationofparabensbisphenolaanditsanalogstriclosanandbenzophenone3levelsinhumanurinebyisotopedilutionuplcmsmsmethodfollowedbysupportedliquidextraction
AT sunyichen determinationofparabensbisphenolaanditsanalogstriclosanandbenzophenone3levelsinhumanurinebyisotopedilutionuplcmsmsmethodfollowedbysupportedliquidextraction
AT changwanting determinationofparabensbisphenolaanditsanalogstriclosanandbenzophenone3levelsinhumanurinebyisotopedilutionuplcmsmsmethodfollowedbysupportedliquidextraction
AT huangpochin determinationofparabensbisphenolaanditsanalogstriclosanandbenzophenone3levelsinhumanurinebyisotopedilutionuplcmsmsmethodfollowedbysupportedliquidextraction