Cargando…

Critical Assessment of Clean-Up Techniques Employed in Simultaneous Analysis of Persistent Organic Pollutants and Polycyclic Aromatic Hydrocarbons in Fatty Samples

Interference of residual lipids is a very common problem in ultratrace analysis of contaminants in fatty matrices. Therefore, quick and effective clean-up techniques applicable to multiple groups of analytes are much needed. Cartridge and dispersive solid-phase extraction (SPE and dSPE) are often us...

Descripción completa

Detalles Bibliográficos
Autores principales: Drábová, Lucie, Dvořáková, Darina, Urbancová, Kateřina, Gramblička, Tomáš, Hajšlová, Jana, Pulkrabová, Jana
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8781265/
https://www.ncbi.nlm.nih.gov/pubmed/35051054
http://dx.doi.org/10.3390/toxics10010012
_version_ 1784638048704659456
author Drábová, Lucie
Dvořáková, Darina
Urbancová, Kateřina
Gramblička, Tomáš
Hajšlová, Jana
Pulkrabová, Jana
author_facet Drábová, Lucie
Dvořáková, Darina
Urbancová, Kateřina
Gramblička, Tomáš
Hajšlová, Jana
Pulkrabová, Jana
author_sort Drábová, Lucie
collection PubMed
description Interference of residual lipids is a very common problem in ultratrace analysis of contaminants in fatty matrices. Therefore, quick and effective clean-up techniques applicable to multiple groups of analytes are much needed. Cartridge and dispersive solid-phase extraction (SPE and dSPE) are often used for this purpose. In this context, we evaluated the lipid clean-up efficiency and performance of four commonly used sorbents—silica, C18, Z-Sep, and EMR-lipid—for the determination of organic pollutants in fatty fish samples (10%) extracted using ethyl acetate or the QuEChERS method. Namely, 17 polychlorinated biphenyls (PCBs), 22 organochlorine pesticides (OCPs), 13 brominated flame retardants (BFRs), 19 per- and polyfluoroalkyl substances (PFAS), and 16 polycyclic aromatic hydrocarbons (PAHs) were determined in this study. The clean-up efficiency was evaluated by direct analysis in real time coupled with time-of-flight mass spectrometry (DART-HRMS). The triacylglycerols (TAGs) content in the purified extracts were significantly reduced. The EMR-lipid sorbent was the most efficient of the dSPE sorbents used for the determination of POPs and PAHs in this study. The recoveries of the POPs and PAHs obtained by the validated QuEChERS method followed by the dSPE EMR-lipid sorbent ranged between 59 and 120%, with repeatabilities ranging between 2 and 23% and LOQs ranging between 0.02 and 1.50 µg·kg(−1).
format Online
Article
Text
id pubmed-8781265
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-87812652022-01-22 Critical Assessment of Clean-Up Techniques Employed in Simultaneous Analysis of Persistent Organic Pollutants and Polycyclic Aromatic Hydrocarbons in Fatty Samples Drábová, Lucie Dvořáková, Darina Urbancová, Kateřina Gramblička, Tomáš Hajšlová, Jana Pulkrabová, Jana Toxics Article Interference of residual lipids is a very common problem in ultratrace analysis of contaminants in fatty matrices. Therefore, quick and effective clean-up techniques applicable to multiple groups of analytes are much needed. Cartridge and dispersive solid-phase extraction (SPE and dSPE) are often used for this purpose. In this context, we evaluated the lipid clean-up efficiency and performance of four commonly used sorbents—silica, C18, Z-Sep, and EMR-lipid—for the determination of organic pollutants in fatty fish samples (10%) extracted using ethyl acetate or the QuEChERS method. Namely, 17 polychlorinated biphenyls (PCBs), 22 organochlorine pesticides (OCPs), 13 brominated flame retardants (BFRs), 19 per- and polyfluoroalkyl substances (PFAS), and 16 polycyclic aromatic hydrocarbons (PAHs) were determined in this study. The clean-up efficiency was evaluated by direct analysis in real time coupled with time-of-flight mass spectrometry (DART-HRMS). The triacylglycerols (TAGs) content in the purified extracts were significantly reduced. The EMR-lipid sorbent was the most efficient of the dSPE sorbents used for the determination of POPs and PAHs in this study. The recoveries of the POPs and PAHs obtained by the validated QuEChERS method followed by the dSPE EMR-lipid sorbent ranged between 59 and 120%, with repeatabilities ranging between 2 and 23% and LOQs ranging between 0.02 and 1.50 µg·kg(−1). MDPI 2022-01-01 /pmc/articles/PMC8781265/ /pubmed/35051054 http://dx.doi.org/10.3390/toxics10010012 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Drábová, Lucie
Dvořáková, Darina
Urbancová, Kateřina
Gramblička, Tomáš
Hajšlová, Jana
Pulkrabová, Jana
Critical Assessment of Clean-Up Techniques Employed in Simultaneous Analysis of Persistent Organic Pollutants and Polycyclic Aromatic Hydrocarbons in Fatty Samples
title Critical Assessment of Clean-Up Techniques Employed in Simultaneous Analysis of Persistent Organic Pollutants and Polycyclic Aromatic Hydrocarbons in Fatty Samples
title_full Critical Assessment of Clean-Up Techniques Employed in Simultaneous Analysis of Persistent Organic Pollutants and Polycyclic Aromatic Hydrocarbons in Fatty Samples
title_fullStr Critical Assessment of Clean-Up Techniques Employed in Simultaneous Analysis of Persistent Organic Pollutants and Polycyclic Aromatic Hydrocarbons in Fatty Samples
title_full_unstemmed Critical Assessment of Clean-Up Techniques Employed in Simultaneous Analysis of Persistent Organic Pollutants and Polycyclic Aromatic Hydrocarbons in Fatty Samples
title_short Critical Assessment of Clean-Up Techniques Employed in Simultaneous Analysis of Persistent Organic Pollutants and Polycyclic Aromatic Hydrocarbons in Fatty Samples
title_sort critical assessment of clean-up techniques employed in simultaneous analysis of persistent organic pollutants and polycyclic aromatic hydrocarbons in fatty samples
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8781265/
https://www.ncbi.nlm.nih.gov/pubmed/35051054
http://dx.doi.org/10.3390/toxics10010012
work_keys_str_mv AT drabovalucie criticalassessmentofcleanuptechniquesemployedinsimultaneousanalysisofpersistentorganicpollutantsandpolycyclicaromatichydrocarbonsinfattysamples
AT dvorakovadarina criticalassessmentofcleanuptechniquesemployedinsimultaneousanalysisofpersistentorganicpollutantsandpolycyclicaromatichydrocarbonsinfattysamples
AT urbancovakaterina criticalassessmentofcleanuptechniquesemployedinsimultaneousanalysisofpersistentorganicpollutantsandpolycyclicaromatichydrocarbonsinfattysamples
AT gramblickatomas criticalassessmentofcleanuptechniquesemployedinsimultaneousanalysisofpersistentorganicpollutantsandpolycyclicaromatichydrocarbonsinfattysamples
AT hajslovajana criticalassessmentofcleanuptechniquesemployedinsimultaneousanalysisofpersistentorganicpollutantsandpolycyclicaromatichydrocarbonsinfattysamples
AT pulkrabovajana criticalassessmentofcleanuptechniquesemployedinsimultaneousanalysisofpersistentorganicpollutantsandpolycyclicaromatichydrocarbonsinfattysamples