Two different sizes of Valencia applicators in non-melanoma skin cancer treatment with iridium-192 high-dose-rate brachytherapy
PURPOSE: The aim of this retrospective study was to analyze tumor control, toxicity, and aesthetic outcome of patients affected by non-melanoma skin cancer (NMSC) and treated with iridium-192 ((192)Ir) high-dose-rate (HDR) brachytherapy (BT) using Valencia applicators at the Division of Radiotherapy...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Termedia Publishing House
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8782077/ https://www.ncbi.nlm.nih.gov/pubmed/35079246 http://dx.doi.org/10.5114/jcb.2021.112111 |
_version_ | 1784638237177806848 |
---|---|
author | Laliscia, Concetta Coccia, Natalina Fuentes, Taiusha Perrone, Franco Paiar, Fabiola |
author_facet | Laliscia, Concetta Coccia, Natalina Fuentes, Taiusha Perrone, Franco Paiar, Fabiola |
author_sort | Laliscia, Concetta |
collection | PubMed |
description | PURPOSE: The aim of this retrospective study was to analyze tumor control, toxicity, and aesthetic outcome of patients affected by non-melanoma skin cancer (NMSC) and treated with iridium-192 ((192)Ir) high-dose-rate (HDR) brachytherapy (BT) using Valencia applicators at the Division of Radiotherapy, University of Pisa. MATERIAL AND METHODS: From June 2015 to December 2020, 95 NMSC patients, including 61.5% basal cell carcinoma and 38.5% squamous cell carcinoma patients, with median age of 83 years (range, 32-96 years) were treated. In total, 182 lesions with a diameter ≤ 25 mm (median, 12 mm) and a depth ≤ 4 mm, located in scalp (19.2%), face (20.9%), chest (8.8%), nose (16.5%), ear (15.4%), and extremities (19.2%) were analyzed. All lesions were treated with (192)Ir-based HDR afterloader using Valencia applicators. 105 lesions (57.7%) were treated with applicator of 20 mm and 77 lesions (42.3%) with applicator of 30 mm in diameter, depending on the size of lesions. Prescribed dose was 40 Gy in 8 fractions (5 Gy/fraction) delivered 2-3 times a week. Biological effective dose (BED) was ≈ 60 Gy. RESULTS: The median follow-up was 14 months (range, 3-59 months). The 2-year local control rate was 96%. According to common terminology criteria for adverse events (CTCAE v. 5.0), G1-G2 acute toxicities included dermatitis (22.0%) and pain (8.2%). The most common G1 late toxicities were hypopigmentation (27.5%) and fibrosis (8.2%), and G2 late toxicity included ulceration (0.5%). No G3 or higher acute or late toxicities were reported. Excellent cosmetic results were observed in 77.5% of the lesions, with one only (0.5%) reported as a poor cosmetic result (ulceration refractory to therapy). CONCLUSIONS: HDR-BT using Valencia applicators is a safe, effective, and well-tolerated treatment modality for NMSC, and can be considered a good alternative for treatment, especially in elderly patients who are often unfit for surgery. |
format | Online Article Text |
id | pubmed-8782077 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Termedia Publishing House |
record_format | MEDLINE/PubMed |
spelling | pubmed-87820772022-01-24 Two different sizes of Valencia applicators in non-melanoma skin cancer treatment with iridium-192 high-dose-rate brachytherapy Laliscia, Concetta Coccia, Natalina Fuentes, Taiusha Perrone, Franco Paiar, Fabiola J Contemp Brachytherapy Original Paper PURPOSE: The aim of this retrospective study was to analyze tumor control, toxicity, and aesthetic outcome of patients affected by non-melanoma skin cancer (NMSC) and treated with iridium-192 ((192)Ir) high-dose-rate (HDR) brachytherapy (BT) using Valencia applicators at the Division of Radiotherapy, University of Pisa. MATERIAL AND METHODS: From June 2015 to December 2020, 95 NMSC patients, including 61.5% basal cell carcinoma and 38.5% squamous cell carcinoma patients, with median age of 83 years (range, 32-96 years) were treated. In total, 182 lesions with a diameter ≤ 25 mm (median, 12 mm) and a depth ≤ 4 mm, located in scalp (19.2%), face (20.9%), chest (8.8%), nose (16.5%), ear (15.4%), and extremities (19.2%) were analyzed. All lesions were treated with (192)Ir-based HDR afterloader using Valencia applicators. 105 lesions (57.7%) were treated with applicator of 20 mm and 77 lesions (42.3%) with applicator of 30 mm in diameter, depending on the size of lesions. Prescribed dose was 40 Gy in 8 fractions (5 Gy/fraction) delivered 2-3 times a week. Biological effective dose (BED) was ≈ 60 Gy. RESULTS: The median follow-up was 14 months (range, 3-59 months). The 2-year local control rate was 96%. According to common terminology criteria for adverse events (CTCAE v. 5.0), G1-G2 acute toxicities included dermatitis (22.0%) and pain (8.2%). The most common G1 late toxicities were hypopigmentation (27.5%) and fibrosis (8.2%), and G2 late toxicity included ulceration (0.5%). No G3 or higher acute or late toxicities were reported. Excellent cosmetic results were observed in 77.5% of the lesions, with one only (0.5%) reported as a poor cosmetic result (ulceration refractory to therapy). CONCLUSIONS: HDR-BT using Valencia applicators is a safe, effective, and well-tolerated treatment modality for NMSC, and can be considered a good alternative for treatment, especially in elderly patients who are often unfit for surgery. Termedia Publishing House 2021-12-30 2021-12 /pmc/articles/PMC8782077/ /pubmed/35079246 http://dx.doi.org/10.5114/jcb.2021.112111 Text en Copyright © 2021 Termedia https://creativecommons.org/licenses/by-nc-sa/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0). License (http://creativecommons.org/licenses/by-nc-sa/4.0/ (https://creativecommons.org/licenses/by-nc-sa/4.0/) ) |
spellingShingle | Original Paper Laliscia, Concetta Coccia, Natalina Fuentes, Taiusha Perrone, Franco Paiar, Fabiola Two different sizes of Valencia applicators in non-melanoma skin cancer treatment with iridium-192 high-dose-rate brachytherapy |
title | Two different sizes of Valencia applicators in non-melanoma skin cancer treatment with iridium-192 high-dose-rate brachytherapy |
title_full | Two different sizes of Valencia applicators in non-melanoma skin cancer treatment with iridium-192 high-dose-rate brachytherapy |
title_fullStr | Two different sizes of Valencia applicators in non-melanoma skin cancer treatment with iridium-192 high-dose-rate brachytherapy |
title_full_unstemmed | Two different sizes of Valencia applicators in non-melanoma skin cancer treatment with iridium-192 high-dose-rate brachytherapy |
title_short | Two different sizes of Valencia applicators in non-melanoma skin cancer treatment with iridium-192 high-dose-rate brachytherapy |
title_sort | two different sizes of valencia applicators in non-melanoma skin cancer treatment with iridium-192 high-dose-rate brachytherapy |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8782077/ https://www.ncbi.nlm.nih.gov/pubmed/35079246 http://dx.doi.org/10.5114/jcb.2021.112111 |
work_keys_str_mv | AT lalisciaconcetta twodifferentsizesofvalenciaapplicatorsinnonmelanomaskincancertreatmentwithiridium192highdoseratebrachytherapy AT coccianatalina twodifferentsizesofvalenciaapplicatorsinnonmelanomaskincancertreatmentwithiridium192highdoseratebrachytherapy AT fuentestaiusha twodifferentsizesofvalenciaapplicatorsinnonmelanomaskincancertreatmentwithiridium192highdoseratebrachytherapy AT perronefranco twodifferentsizesofvalenciaapplicatorsinnonmelanomaskincancertreatmentwithiridium192highdoseratebrachytherapy AT paiarfabiola twodifferentsizesofvalenciaapplicatorsinnonmelanomaskincancertreatmentwithiridium192highdoseratebrachytherapy |