Cargando…

Reweighting of Binaural Localization Cues in Bilateral Cochlear-Implant Listeners

Normal-hearing (NH) listeners rely on two binaural cues, the interaural time (ITD) and level difference (ILD), for azimuthal sound localization. Cochlear-implant (CI) listeners, however, rely almost entirely on ILDs. One reason is that present-day clinical CI stimulation strategies do not convey sal...

Descripción completa

Detalles Bibliográficos
Autores principales: Klingel, Maike, Laback, Bernhard
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8782964/
https://www.ncbi.nlm.nih.gov/pubmed/34812980
http://dx.doi.org/10.1007/s10162-021-00821-3
_version_ 1784638422733815808
author Klingel, Maike
Laback, Bernhard
author_facet Klingel, Maike
Laback, Bernhard
author_sort Klingel, Maike
collection PubMed
description Normal-hearing (NH) listeners rely on two binaural cues, the interaural time (ITD) and level difference (ILD), for azimuthal sound localization. Cochlear-implant (CI) listeners, however, rely almost entirely on ILDs. One reason is that present-day clinical CI stimulation strategies do not convey salient ITD cues. But even when presenting ITDs under optimal conditions using a research interface, ITD sensitivity is lower in CI compared to NH listeners. Since it has recently been shown that NH listeners change their ITD/ILD weighting when only one of the cues is consistent with visual information, such reweighting might add to CI listeners’ low perceptual contribution of ITDs, given their daily exposure to reliable ILDs but unreliable ITDs. Six bilateral CI listeners completed a multi-day lateralization training visually reinforcing ITDs, flanked by a pre- and post-measurement of ITD/ILD weights without visual reinforcement. Using direct electric stimulation, we presented 100- and 300-pps pulse trains at a single interaurally place-matched electrode pair, conveying ITDs and ILDs in various spatially consistent and inconsistent combinations. The listeners’ task was to lateralize the stimuli in a virtual environment. Additionally, ITD and ILD thresholds were measured before and after training. For 100-pps stimuli, the lateralization training increased the contribution of ITDs slightly, but significantly. Thresholds were neither affected by the training nor correlated with weights. For 300-pps stimuli, ITD weights were lower and ITD thresholds larger, but there was no effect of training. On average across test sessions, adding azimuth-dependent ITDs to stimuli containing ILDs increased the extent of lateralization for both 100- and 300-pps stimuli. The results suggest that low-rate ITD cues, robustly encoded with future CI systems, may be better exploitable for sound localization after increasing their perceptual weight via training.
format Online
Article
Text
id pubmed-8782964
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-87829642022-02-02 Reweighting of Binaural Localization Cues in Bilateral Cochlear-Implant Listeners Klingel, Maike Laback, Bernhard J Assoc Res Otolaryngol Research Article Normal-hearing (NH) listeners rely on two binaural cues, the interaural time (ITD) and level difference (ILD), for azimuthal sound localization. Cochlear-implant (CI) listeners, however, rely almost entirely on ILDs. One reason is that present-day clinical CI stimulation strategies do not convey salient ITD cues. But even when presenting ITDs under optimal conditions using a research interface, ITD sensitivity is lower in CI compared to NH listeners. Since it has recently been shown that NH listeners change their ITD/ILD weighting when only one of the cues is consistent with visual information, such reweighting might add to CI listeners’ low perceptual contribution of ITDs, given their daily exposure to reliable ILDs but unreliable ITDs. Six bilateral CI listeners completed a multi-day lateralization training visually reinforcing ITDs, flanked by a pre- and post-measurement of ITD/ILD weights without visual reinforcement. Using direct electric stimulation, we presented 100- and 300-pps pulse trains at a single interaurally place-matched electrode pair, conveying ITDs and ILDs in various spatially consistent and inconsistent combinations. The listeners’ task was to lateralize the stimuli in a virtual environment. Additionally, ITD and ILD thresholds were measured before and after training. For 100-pps stimuli, the lateralization training increased the contribution of ITDs slightly, but significantly. Thresholds were neither affected by the training nor correlated with weights. For 300-pps stimuli, ITD weights were lower and ITD thresholds larger, but there was no effect of training. On average across test sessions, adding azimuth-dependent ITDs to stimuli containing ILDs increased the extent of lateralization for both 100- and 300-pps stimuli. The results suggest that low-rate ITD cues, robustly encoded with future CI systems, may be better exploitable for sound localization after increasing their perceptual weight via training. Springer US 2021-11-23 2022-02 /pmc/articles/PMC8782964/ /pubmed/34812980 http://dx.doi.org/10.1007/s10162-021-00821-3 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Research Article
Klingel, Maike
Laback, Bernhard
Reweighting of Binaural Localization Cues in Bilateral Cochlear-Implant Listeners
title Reweighting of Binaural Localization Cues in Bilateral Cochlear-Implant Listeners
title_full Reweighting of Binaural Localization Cues in Bilateral Cochlear-Implant Listeners
title_fullStr Reweighting of Binaural Localization Cues in Bilateral Cochlear-Implant Listeners
title_full_unstemmed Reweighting of Binaural Localization Cues in Bilateral Cochlear-Implant Listeners
title_short Reweighting of Binaural Localization Cues in Bilateral Cochlear-Implant Listeners
title_sort reweighting of binaural localization cues in bilateral cochlear-implant listeners
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8782964/
https://www.ncbi.nlm.nih.gov/pubmed/34812980
http://dx.doi.org/10.1007/s10162-021-00821-3
work_keys_str_mv AT klingelmaike reweightingofbinaurallocalizationcuesinbilateralcochlearimplantlisteners
AT labackbernhard reweightingofbinaurallocalizationcuesinbilateralcochlearimplantlisteners