Cargando…

The Predictive Accuracy of the CareMOSAIC Risk Assessment for Discharge Disposition in Medicare Bundle Patients After Total Joint Arthroplasty

BACKGROUND: This article evaluates the predictive accuracy of the CareMOSAIC Risk Assessment for discharge disposition in Medicare patients undergoing total joint arthroplasty. METHODS: Retrospectively collected data from a single institution on 499 consecutive Medicare patients who underwent primar...

Descripción completa

Detalles Bibliográficos
Autores principales: Anderson, Corey, Schweinle, William
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8783109/
https://www.ncbi.nlm.nih.gov/pubmed/35097172
http://dx.doi.org/10.1016/j.artd.2021.11.020
_version_ 1784638453286174720
author Anderson, Corey
Schweinle, William
author_facet Anderson, Corey
Schweinle, William
author_sort Anderson, Corey
collection PubMed
description BACKGROUND: This article evaluates the predictive accuracy of the CareMOSAIC Risk Assessment for discharge disposition in Medicare patients undergoing total joint arthroplasty. METHODS: Retrospectively collected data from a single institution on 499 consecutive Medicare patients who underwent primary total hip arthroplasty or total knee arthroplasty were reviewed. The CareMOSAIC Risk Assessment was completed by each patient during the preoperative period. The CareMOSAIC Risk Assessment scores were calculated via the CareMOSAIC software, and the scores indicate a risk category for each patient as it relates to post–acute care discharge needs. RESULTS: The CareMOSAIC Risk Assessment with a binary logistic regression area under the receiver operating characteristic curve of 0.798 appears to be a reliable tool for predicting discharge disposition. The assessment had a positive predictive value of 90.0% and negative predictive value of 76.3% for discharge disposition. CONCLUSIONS: The CareMOSAIC Risk Assessment effectively predicts the discharge disposition for Medicare patients undergoing total hip or total knee arthroplasty.
format Online
Article
Text
id pubmed-8783109
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-87831092022-01-28 The Predictive Accuracy of the CareMOSAIC Risk Assessment for Discharge Disposition in Medicare Bundle Patients After Total Joint Arthroplasty Anderson, Corey Schweinle, William Arthroplast Today Original Research BACKGROUND: This article evaluates the predictive accuracy of the CareMOSAIC Risk Assessment for discharge disposition in Medicare patients undergoing total joint arthroplasty. METHODS: Retrospectively collected data from a single institution on 499 consecutive Medicare patients who underwent primary total hip arthroplasty or total knee arthroplasty were reviewed. The CareMOSAIC Risk Assessment was completed by each patient during the preoperative period. The CareMOSAIC Risk Assessment scores were calculated via the CareMOSAIC software, and the scores indicate a risk category for each patient as it relates to post–acute care discharge needs. RESULTS: The CareMOSAIC Risk Assessment with a binary logistic regression area under the receiver operating characteristic curve of 0.798 appears to be a reliable tool for predicting discharge disposition. The assessment had a positive predictive value of 90.0% and negative predictive value of 76.3% for discharge disposition. CONCLUSIONS: The CareMOSAIC Risk Assessment effectively predicts the discharge disposition for Medicare patients undergoing total hip or total knee arthroplasty. Elsevier 2022-01-20 /pmc/articles/PMC8783109/ /pubmed/35097172 http://dx.doi.org/10.1016/j.artd.2021.11.020 Text en © 2021 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research
Anderson, Corey
Schweinle, William
The Predictive Accuracy of the CareMOSAIC Risk Assessment for Discharge Disposition in Medicare Bundle Patients After Total Joint Arthroplasty
title The Predictive Accuracy of the CareMOSAIC Risk Assessment for Discharge Disposition in Medicare Bundle Patients After Total Joint Arthroplasty
title_full The Predictive Accuracy of the CareMOSAIC Risk Assessment for Discharge Disposition in Medicare Bundle Patients After Total Joint Arthroplasty
title_fullStr The Predictive Accuracy of the CareMOSAIC Risk Assessment for Discharge Disposition in Medicare Bundle Patients After Total Joint Arthroplasty
title_full_unstemmed The Predictive Accuracy of the CareMOSAIC Risk Assessment for Discharge Disposition in Medicare Bundle Patients After Total Joint Arthroplasty
title_short The Predictive Accuracy of the CareMOSAIC Risk Assessment for Discharge Disposition in Medicare Bundle Patients After Total Joint Arthroplasty
title_sort predictive accuracy of the caremosaic risk assessment for discharge disposition in medicare bundle patients after total joint arthroplasty
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8783109/
https://www.ncbi.nlm.nih.gov/pubmed/35097172
http://dx.doi.org/10.1016/j.artd.2021.11.020
work_keys_str_mv AT andersoncorey thepredictiveaccuracyofthecaremosaicriskassessmentfordischargedispositioninmedicarebundlepatientsaftertotaljointarthroplasty
AT schweinlewilliam thepredictiveaccuracyofthecaremosaicriskassessmentfordischargedispositioninmedicarebundlepatientsaftertotaljointarthroplasty
AT andersoncorey predictiveaccuracyofthecaremosaicriskassessmentfordischargedispositioninmedicarebundlepatientsaftertotaljointarthroplasty
AT schweinlewilliam predictiveaccuracyofthecaremosaicriskassessmentfordischargedispositioninmedicarebundlepatientsaftertotaljointarthroplasty