A proposed combination of flat-panel detector and mobile X-ray systems for low-dose image-guided central venous catheter insertion

A central venous catheter (CVC) should be inserted at the optimum position to infuse medicines, blood products, nutrients, or fluids. Positioning of the catheter tip is commonly performed under landmark or fluoroscopic guidance. However, Japanese regulations do not allow the performing of fluoroscop...

Descripción completa

Detalles Bibliográficos
Autores principales: Tashiro, Masami, Kubo, Hitoshi, Kanezawa, Chie, Ito, Hiroshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Fukushima Society of Medical Science 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8784190/
https://www.ncbi.nlm.nih.gov/pubmed/34937810
http://dx.doi.org/10.5387/fms.2021-27
_version_ 1784638679776493568
author Tashiro, Masami
Kubo, Hitoshi
Kanezawa, Chie
Ito, Hiroshi
author_facet Tashiro, Masami
Kubo, Hitoshi
Kanezawa, Chie
Ito, Hiroshi
author_sort Tashiro, Masami
collection PubMed
description A central venous catheter (CVC) should be inserted at the optimum position to infuse medicines, blood products, nutrients, or fluids. Positioning of the catheter tip is commonly performed under landmark or fluoroscopic guidance. However, Japanese regulations do not allow the performing of fluoroscopy-guided procedures outside of the fluoroscopy room. We hypothesized that a new image-guided CVC placement technique by combining a wireless flat-panel detector (FPD) and a mobile X-ray system could be applied at the bedside to support CVC insertion. A CVC attached to a chest phantom in conjunction with the polymethyl methacrylate (PMMA) phantom was imaged, contrast-to-noise ratio (CNR) was measured with images, and radiologists and emergency physicians rated the catheter images using a Likert scale for visual evaluation. The minimum dose of the FPD and mobile X-ray system was reduced by at least 98% compared with that of the X-ray fluoroscopy system. The CNR decreased with the increasing PMMA phantom thickness. However, results of the visual evaluation were maintained at the clinically usable score with low-dose imaging up to a 6-cm thickness of the PMMA phantom. In conclusion, the combination of FPD and mobile X-ray systems is particularly effective in the emergency room setting where such procedures are required to be performed with urgency.
format Online
Article
Text
id pubmed-8784190
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The Fukushima Society of Medical Science
record_format MEDLINE/PubMed
spelling pubmed-87841902022-02-02 A proposed combination of flat-panel detector and mobile X-ray systems for low-dose image-guided central venous catheter insertion Tashiro, Masami Kubo, Hitoshi Kanezawa, Chie Ito, Hiroshi Fukushima J Med Sci Original Article A central venous catheter (CVC) should be inserted at the optimum position to infuse medicines, blood products, nutrients, or fluids. Positioning of the catheter tip is commonly performed under landmark or fluoroscopic guidance. However, Japanese regulations do not allow the performing of fluoroscopy-guided procedures outside of the fluoroscopy room. We hypothesized that a new image-guided CVC placement technique by combining a wireless flat-panel detector (FPD) and a mobile X-ray system could be applied at the bedside to support CVC insertion. A CVC attached to a chest phantom in conjunction with the polymethyl methacrylate (PMMA) phantom was imaged, contrast-to-noise ratio (CNR) was measured with images, and radiologists and emergency physicians rated the catheter images using a Likert scale for visual evaluation. The minimum dose of the FPD and mobile X-ray system was reduced by at least 98% compared with that of the X-ray fluoroscopy system. The CNR decreased with the increasing PMMA phantom thickness. However, results of the visual evaluation were maintained at the clinically usable score with low-dose imaging up to a 6-cm thickness of the PMMA phantom. In conclusion, the combination of FPD and mobile X-ray systems is particularly effective in the emergency room setting where such procedures are required to be performed with urgency. The Fukushima Society of Medical Science 2021-12-21 2021 /pmc/articles/PMC8784190/ /pubmed/34937810 http://dx.doi.org/10.5387/fms.2021-27 Text en © 2021 The Fukushima Society of Medical Science https://creativecommons.org/licenses/by-nc-sa/4.0/This article is licensed under a Creative Commons [Attribution-NonCommercial-ShareAlike 4.0 International] license. https://creativecommons.org/licenses/by-nc-sa/4.0/
spellingShingle Original Article
Tashiro, Masami
Kubo, Hitoshi
Kanezawa, Chie
Ito, Hiroshi
A proposed combination of flat-panel detector and mobile X-ray systems for low-dose image-guided central venous catheter insertion
title A proposed combination of flat-panel detector and mobile X-ray systems for low-dose image-guided central venous catheter insertion
title_full A proposed combination of flat-panel detector and mobile X-ray systems for low-dose image-guided central venous catheter insertion
title_fullStr A proposed combination of flat-panel detector and mobile X-ray systems for low-dose image-guided central venous catheter insertion
title_full_unstemmed A proposed combination of flat-panel detector and mobile X-ray systems for low-dose image-guided central venous catheter insertion
title_short A proposed combination of flat-panel detector and mobile X-ray systems for low-dose image-guided central venous catheter insertion
title_sort proposed combination of flat-panel detector and mobile x-ray systems for low-dose image-guided central venous catheter insertion
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8784190/
https://www.ncbi.nlm.nih.gov/pubmed/34937810
http://dx.doi.org/10.5387/fms.2021-27
work_keys_str_mv AT tashiromasami aproposedcombinationofflatpaneldetectorandmobilexraysystemsforlowdoseimageguidedcentralvenouscatheterinsertion
AT kubohitoshi aproposedcombinationofflatpaneldetectorandmobilexraysystemsforlowdoseimageguidedcentralvenouscatheterinsertion
AT kanezawachie aproposedcombinationofflatpaneldetectorandmobilexraysystemsforlowdoseimageguidedcentralvenouscatheterinsertion
AT itohiroshi aproposedcombinationofflatpaneldetectorandmobilexraysystemsforlowdoseimageguidedcentralvenouscatheterinsertion
AT tashiromasami proposedcombinationofflatpaneldetectorandmobilexraysystemsforlowdoseimageguidedcentralvenouscatheterinsertion
AT kubohitoshi proposedcombinationofflatpaneldetectorandmobilexraysystemsforlowdoseimageguidedcentralvenouscatheterinsertion
AT kanezawachie proposedcombinationofflatpaneldetectorandmobilexraysystemsforlowdoseimageguidedcentralvenouscatheterinsertion
AT itohiroshi proposedcombinationofflatpaneldetectorandmobilexraysystemsforlowdoseimageguidedcentralvenouscatheterinsertion