Cargando…

Long-Term Results of Delta Ceramic-on-Ceramic Total Hip Arthroplasty

BACKGROUND: Ceramic-on-ceramic (COC) bearings in total hip arthroplasty (THA) have long been considered the coupling with the lowest overall wear. However, concerns about complications such as ceramic breakage and noise, combined with the improved performance of polyethylene, have limited its use in...

Descripción completa

Detalles Bibliográficos
Autores principales: Blumenfeld, Thomas J., Politi, Joel, Coker, Sean, O’Dell, Tammy, Hamilton, William
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8784293/
https://www.ncbi.nlm.nih.gov/pubmed/35106349
http://dx.doi.org/10.1016/j.artd.2021.11.006
_version_ 1784638704008036352
author Blumenfeld, Thomas J.
Politi, Joel
Coker, Sean
O’Dell, Tammy
Hamilton, William
author_facet Blumenfeld, Thomas J.
Politi, Joel
Coker, Sean
O’Dell, Tammy
Hamilton, William
author_sort Blumenfeld, Thomas J.
collection PubMed
description BACKGROUND: Ceramic-on-ceramic (COC) bearings in total hip arthroplasty (THA) have long been considered the coupling with the lowest overall wear. However, concerns about complications such as ceramic breakage and noise, combined with the improved performance of polyethylene, have limited its use in the United States. This postapproval follow-up reports long-term (10 years) results of Delta COC in THA patients primarily enrolled in an Investigational Device Exemption study. METHODS: Patients received Delta COC THA in a prospective multicenter study with either 28-mm (N = 105 hips in 104 patients) or 36-mm (N = 81) articulations. Annual clinical and radiographic evaluations were performed for years 5 to 10, and study patients were asked about hip noises and reproducibility. RESULTS: There have been 4 additional reports of noise in 4 patients (COC 28, n = 3; COC 36, n = 1). The cumulative incidence rate for squeaking or noise at 10 years is 5.9% for COC 28 and 13.5% for COC 36. There have been 2 additional reports of dislocation in 2 patients (COC 28, n = 1; COC 36, n = 1). The cumulative incidence rate for dislocation at 10 years is 3.7% for COC 28 and 3.5% for COC 36. At 10 years, there were greater than 40 hips available for follow-up. At mean 10-year follow-up, there were a total of 3 ceramic liner fractures, but none since the previous report. There were no revisions in the 28-mm cohort, and 2 revisions in the 36-mm cohort (1 for recurrent dislocation and 1 for pain and noise). Overall Kaplan-Meier survivorship was 95.96% at 10.5 years (28 mm: 97.68% at 10.2 years; 36 mm: 94.11% at 10.4 years.) CONCLUSIONS: At 10-year follow-up, we report excellent results in regard to survivorship, with one patient revised for pain with associated squeaking.
format Online
Article
Text
id pubmed-8784293
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-87842932022-01-31 Long-Term Results of Delta Ceramic-on-Ceramic Total Hip Arthroplasty Blumenfeld, Thomas J. Politi, Joel Coker, Sean O’Dell, Tammy Hamilton, William Arthroplast Today Original Research BACKGROUND: Ceramic-on-ceramic (COC) bearings in total hip arthroplasty (THA) have long been considered the coupling with the lowest overall wear. However, concerns about complications such as ceramic breakage and noise, combined with the improved performance of polyethylene, have limited its use in the United States. This postapproval follow-up reports long-term (10 years) results of Delta COC in THA patients primarily enrolled in an Investigational Device Exemption study. METHODS: Patients received Delta COC THA in a prospective multicenter study with either 28-mm (N = 105 hips in 104 patients) or 36-mm (N = 81) articulations. Annual clinical and radiographic evaluations were performed for years 5 to 10, and study patients were asked about hip noises and reproducibility. RESULTS: There have been 4 additional reports of noise in 4 patients (COC 28, n = 3; COC 36, n = 1). The cumulative incidence rate for squeaking or noise at 10 years is 5.9% for COC 28 and 13.5% for COC 36. There have been 2 additional reports of dislocation in 2 patients (COC 28, n = 1; COC 36, n = 1). The cumulative incidence rate for dislocation at 10 years is 3.7% for COC 28 and 3.5% for COC 36. At 10 years, there were greater than 40 hips available for follow-up. At mean 10-year follow-up, there were a total of 3 ceramic liner fractures, but none since the previous report. There were no revisions in the 28-mm cohort, and 2 revisions in the 36-mm cohort (1 for recurrent dislocation and 1 for pain and noise). Overall Kaplan-Meier survivorship was 95.96% at 10.5 years (28 mm: 97.68% at 10.2 years; 36 mm: 94.11% at 10.4 years.) CONCLUSIONS: At 10-year follow-up, we report excellent results in regard to survivorship, with one patient revised for pain with associated squeaking. Elsevier 2022-01-18 /pmc/articles/PMC8784293/ /pubmed/35106349 http://dx.doi.org/10.1016/j.artd.2021.11.006 Text en © 2021 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research
Blumenfeld, Thomas J.
Politi, Joel
Coker, Sean
O’Dell, Tammy
Hamilton, William
Long-Term Results of Delta Ceramic-on-Ceramic Total Hip Arthroplasty
title Long-Term Results of Delta Ceramic-on-Ceramic Total Hip Arthroplasty
title_full Long-Term Results of Delta Ceramic-on-Ceramic Total Hip Arthroplasty
title_fullStr Long-Term Results of Delta Ceramic-on-Ceramic Total Hip Arthroplasty
title_full_unstemmed Long-Term Results of Delta Ceramic-on-Ceramic Total Hip Arthroplasty
title_short Long-Term Results of Delta Ceramic-on-Ceramic Total Hip Arthroplasty
title_sort long-term results of delta ceramic-on-ceramic total hip arthroplasty
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8784293/
https://www.ncbi.nlm.nih.gov/pubmed/35106349
http://dx.doi.org/10.1016/j.artd.2021.11.006
work_keys_str_mv AT blumenfeldthomasj longtermresultsofdeltaceramiconceramictotalhiparthroplasty
AT politijoel longtermresultsofdeltaceramiconceramictotalhiparthroplasty
AT cokersean longtermresultsofdeltaceramiconceramictotalhiparthroplasty
AT odelltammy longtermresultsofdeltaceramiconceramictotalhiparthroplasty
AT hamiltonwilliam longtermresultsofdeltaceramiconceramictotalhiparthroplasty