Static and Dynamic Pupil Characteristics in Myopic Anisometropic Amblyopia
OBJECTIVES: The purpose of this study was to compare static and dynamic pupillometry measurements in patients with myopic anisometropic amblyopia with those of age-matched, healthy subjects. METHODS: This prospective, cross-sectional study consisted of 29 patients with myopic anisometropic amblyopia...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Kare Publishing
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8784473/ https://www.ncbi.nlm.nih.gov/pubmed/35098069 http://dx.doi.org/10.14744/bej.2020.08760 |
_version_ | 1784638747595243520 |
---|---|
author | Kiziltoprak, Hasan Tekin, Kemal Yetkin, Esat Sekeroglu, Mehmet Ali |
author_facet | Kiziltoprak, Hasan Tekin, Kemal Yetkin, Esat Sekeroglu, Mehmet Ali |
author_sort | Kiziltoprak, Hasan |
collection | PubMed |
description | OBJECTIVES: The purpose of this study was to compare static and dynamic pupillometry measurements in patients with myopic anisometropic amblyopia with those of age-matched, healthy subjects. METHODS: This prospective, cross-sectional study consisted of 29 patients with myopic anisometropic amblyopia and 83 control subjects. While both the amblyopic eye and the fellow eye of patients with myopic anisometropic amblyopia were examined, data were only recorded for the right eye of the subjects in the control group. Static pupillometry measurements determined included the scotopic pupil diameter (PD), mesopic PD, low photopic PD, and high photopic PD. Subsequently, dynamic pupillometry measurements were obtained, including the resting diameter, amplitude of pupil contraction, latency of pupil contraction, duration of pupil contraction, velocity of pupil contraction, latency of pupil dilation, duration of pupil dilation, and velocity of pupil dilation. RESULTS: In the myopic anisometropia patients, there was a statistically significant difference in the low photopic PD and high photopic PD values of the amblyopic eyes and the corresponding fellow eyes compared with the healthy subjects (p<0.05 for each). These parameters of low photopic PD and high photopic PD were similar between the highly myopic eyes and the fellow eyes. There was no statistically significant difference in the mesopic or scotopic PD values between any of the groups (p>0.05 for each). There were no significant differences in the dynamic pupillometric measurements between the study and control eyes. CONCLUSION: These results confirm that amblyopia is a binocular disorder. The dynamic pupillary responses were similar in the highly myopic and fellow eyes, indicating that evaluation of relative afferent pupillary defects may not be a useful test to differentiate amblyopic eyes from healthy corresponding eyes. |
format | Online Article Text |
id | pubmed-8784473 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Kare Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-87844732022-01-28 Static and Dynamic Pupil Characteristics in Myopic Anisometropic Amblyopia Kiziltoprak, Hasan Tekin, Kemal Yetkin, Esat Sekeroglu, Mehmet Ali Beyoglu Eye J Original Article OBJECTIVES: The purpose of this study was to compare static and dynamic pupillometry measurements in patients with myopic anisometropic amblyopia with those of age-matched, healthy subjects. METHODS: This prospective, cross-sectional study consisted of 29 patients with myopic anisometropic amblyopia and 83 control subjects. While both the amblyopic eye and the fellow eye of patients with myopic anisometropic amblyopia were examined, data were only recorded for the right eye of the subjects in the control group. Static pupillometry measurements determined included the scotopic pupil diameter (PD), mesopic PD, low photopic PD, and high photopic PD. Subsequently, dynamic pupillometry measurements were obtained, including the resting diameter, amplitude of pupil contraction, latency of pupil contraction, duration of pupil contraction, velocity of pupil contraction, latency of pupil dilation, duration of pupil dilation, and velocity of pupil dilation. RESULTS: In the myopic anisometropia patients, there was a statistically significant difference in the low photopic PD and high photopic PD values of the amblyopic eyes and the corresponding fellow eyes compared with the healthy subjects (p<0.05 for each). These parameters of low photopic PD and high photopic PD were similar between the highly myopic eyes and the fellow eyes. There was no statistically significant difference in the mesopic or scotopic PD values between any of the groups (p>0.05 for each). There were no significant differences in the dynamic pupillometric measurements between the study and control eyes. CONCLUSION: These results confirm that amblyopia is a binocular disorder. The dynamic pupillary responses were similar in the highly myopic and fellow eyes, indicating that evaluation of relative afferent pupillary defects may not be a useful test to differentiate amblyopic eyes from healthy corresponding eyes. Kare Publishing 2020-07-29 /pmc/articles/PMC8784473/ /pubmed/35098069 http://dx.doi.org/10.14744/bej.2020.08760 Text en Copyright: © 2020 by Beyoglu Eye Training and Research Hospital https://creativecommons.org/licenses/by-nc-sa/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License |
spellingShingle | Original Article Kiziltoprak, Hasan Tekin, Kemal Yetkin, Esat Sekeroglu, Mehmet Ali Static and Dynamic Pupil Characteristics in Myopic Anisometropic Amblyopia |
title | Static and Dynamic Pupil Characteristics in Myopic Anisometropic Amblyopia |
title_full | Static and Dynamic Pupil Characteristics in Myopic Anisometropic Amblyopia |
title_fullStr | Static and Dynamic Pupil Characteristics in Myopic Anisometropic Amblyopia |
title_full_unstemmed | Static and Dynamic Pupil Characteristics in Myopic Anisometropic Amblyopia |
title_short | Static and Dynamic Pupil Characteristics in Myopic Anisometropic Amblyopia |
title_sort | static and dynamic pupil characteristics in myopic anisometropic amblyopia |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8784473/ https://www.ncbi.nlm.nih.gov/pubmed/35098069 http://dx.doi.org/10.14744/bej.2020.08760 |
work_keys_str_mv | AT kiziltoprakhasan staticanddynamicpupilcharacteristicsinmyopicanisometropicamblyopia AT tekinkemal staticanddynamicpupilcharacteristicsinmyopicanisometropicamblyopia AT yetkinesat staticanddynamicpupilcharacteristicsinmyopicanisometropicamblyopia AT sekeroglumehmetali staticanddynamicpupilcharacteristicsinmyopicanisometropicamblyopia |