Cargando…

In vivo skin anisotropy dataset from annular suction test

To characterize the anisotropic and viscoelastic behaviors of the skin, we conducted an experimental campaign of in-vivo suction tests using the CutiScan®CS100 device from Courage and Khazaka electronics. In this data paper, we present the raw acquired data of the tests and their respective treated...

Descripción completa

Detalles Bibliográficos
Autores principales: Elouneg, Aflah, Bertin, Audrey, Lucot, Quentin, Tissot, Vincent, Jacquet, Emmanuelle, Chambert, Jérôme, Lejeune, Arnaud
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8784637/
https://www.ncbi.nlm.nih.gov/pubmed/35106340
http://dx.doi.org/10.1016/j.dib.2022.107835
_version_ 1784638785398505472
author Elouneg, Aflah
Bertin, Audrey
Lucot, Quentin
Tissot, Vincent
Jacquet, Emmanuelle
Chambert, Jérôme
Lejeune, Arnaud
author_facet Elouneg, Aflah
Bertin, Audrey
Lucot, Quentin
Tissot, Vincent
Jacquet, Emmanuelle
Chambert, Jérôme
Lejeune, Arnaud
author_sort Elouneg, Aflah
collection PubMed
description To characterize the anisotropic and viscoelastic behaviors of the skin, we conducted an experimental campaign of in-vivo suction tests using the CutiScan®CS100 device from Courage and Khazaka electronics. In this data paper, we present the raw acquired data of the tests and their respective treated data. The tests were performed 30 times on the anterior forearm of a 28-year-old Caucasian male at different pressure set-points, ranging from 100 to 500 mbar with an increment of 20 mbar, at ambient temperature in a windowless room. The primary dataset consists of videos recorded by a probe camera associated with the CutiScan® device during the tests. After data treatment with DIC (Digital Image Correlation) technique and based on a homemade Python program, we have obtained secondary data tables and 2D displacement for all mapped grid nodes.
format Online
Article
Text
id pubmed-8784637
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-87846372022-01-31 In vivo skin anisotropy dataset from annular suction test Elouneg, Aflah Bertin, Audrey Lucot, Quentin Tissot, Vincent Jacquet, Emmanuelle Chambert, Jérôme Lejeune, Arnaud Data Brief Data Article To characterize the anisotropic and viscoelastic behaviors of the skin, we conducted an experimental campaign of in-vivo suction tests using the CutiScan®CS100 device from Courage and Khazaka electronics. In this data paper, we present the raw acquired data of the tests and their respective treated data. The tests were performed 30 times on the anterior forearm of a 28-year-old Caucasian male at different pressure set-points, ranging from 100 to 500 mbar with an increment of 20 mbar, at ambient temperature in a windowless room. The primary dataset consists of videos recorded by a probe camera associated with the CutiScan® device during the tests. After data treatment with DIC (Digital Image Correlation) technique and based on a homemade Python program, we have obtained secondary data tables and 2D displacement for all mapped grid nodes. Elsevier 2022-01-15 /pmc/articles/PMC8784637/ /pubmed/35106340 http://dx.doi.org/10.1016/j.dib.2022.107835 Text en © 2022 Published by Elsevier Inc. https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Data Article
Elouneg, Aflah
Bertin, Audrey
Lucot, Quentin
Tissot, Vincent
Jacquet, Emmanuelle
Chambert, Jérôme
Lejeune, Arnaud
In vivo skin anisotropy dataset from annular suction test
title In vivo skin anisotropy dataset from annular suction test
title_full In vivo skin anisotropy dataset from annular suction test
title_fullStr In vivo skin anisotropy dataset from annular suction test
title_full_unstemmed In vivo skin anisotropy dataset from annular suction test
title_short In vivo skin anisotropy dataset from annular suction test
title_sort in vivo skin anisotropy dataset from annular suction test
topic Data Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8784637/
https://www.ncbi.nlm.nih.gov/pubmed/35106340
http://dx.doi.org/10.1016/j.dib.2022.107835
work_keys_str_mv AT elounegaflah invivoskinanisotropydatasetfromannularsuctiontest
AT bertinaudrey invivoskinanisotropydatasetfromannularsuctiontest
AT lucotquentin invivoskinanisotropydatasetfromannularsuctiontest
AT tissotvincent invivoskinanisotropydatasetfromannularsuctiontest
AT jacquetemmanuelle invivoskinanisotropydatasetfromannularsuctiontest
AT chambertjerome invivoskinanisotropydatasetfromannularsuctiontest
AT lejeunearnaud invivoskinanisotropydatasetfromannularsuctiontest