Cargando…
Periprocedural safety of saccular aneurysm embolization with the Penumbra SMART Coil System: a SMART registry subset analysis
BACKGROUND: Using data from the SMART registry, we report on periprocedural safety of the Penumbra SMART Coil System for endovascular coil embolization of saccular intracranial aneurysms. METHODS: The SMART registry was a prospective, multi-center registry of site standard of care endovascular coili...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8785012/ https://www.ncbi.nlm.nih.gov/pubmed/33593799 http://dx.doi.org/10.1136/neurintsurg-2020-016943 |
_version_ | 1784638868414267392 |
---|---|
author | Starke, Robert M Park, Min S Bellon, Richard Bohnstedt, Bradley Schirmer, Clemens M De Leacy, Reade Fiorella, David Yoo, Albert J Spiotta, Alejandro M |
author_facet | Starke, Robert M Park, Min S Bellon, Richard Bohnstedt, Bradley Schirmer, Clemens M De Leacy, Reade Fiorella, David Yoo, Albert J Spiotta, Alejandro M |
author_sort | Starke, Robert M |
collection | PubMed |
description | BACKGROUND: Using data from the SMART registry, we report on periprocedural safety of the Penumbra SMART Coil System for endovascular coil embolization of saccular intracranial aneurysms. METHODS: The SMART registry was a prospective, multi-center registry of site standard of care endovascular coiling procedures performed using at least 75% Penumbra SMART Coil, PC400, and/or POD coils. This subset analysis reports on the periprocedural safety outcomes of the saccular intracranial aneurysm cohort. Predictors of rupture/re-rupture or perforation (RRP), thromboembolic complications, and device- or procedure-related adverse events (AEs) were determined in univariate and multivariate analysis. RESULTS: Between June 2016 and August 2018, 851 saccular aneurysm patients (31.0%, 264/851 ruptured) were enrolled across 66 North American centers. Clinically significant (ie, a serious adverse event) RRP occurred in 2.0% (17/851) of cases – 1.9% (5/264) for the ruptured cohort and 2.0% (12/587) for the un-ruptured cohort. Clinically significant thromboembolic events occurred in 3.1% (26/851) of cases – 5.3% (14/264) for the ruptured cohort and 2.0% (12/587) for the un-ruptured cohort. Multivariate predictors of periprocedural RRP were increased packing density and adjunctive treatment with a balloon. For periprocedural thromboembolic events, multivariate predictors were bifurcation location and ruptured status. For device- or procedure-related AEs, multivariate predictors were bifurcation location and adjunctive treatment with stent or balloon. CONCLUSION: The low rates of thromboembolic complications and RRP events demonstrate the adequate safety profile of the SMART Coil System to treat cerebral aneurysms in routine clinical practice. TRIAL REGISTRATION NUMBER: NCT02729740. |
format | Online Article Text |
id | pubmed-8785012 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-87850122022-02-04 Periprocedural safety of saccular aneurysm embolization with the Penumbra SMART Coil System: a SMART registry subset analysis Starke, Robert M Park, Min S Bellon, Richard Bohnstedt, Bradley Schirmer, Clemens M De Leacy, Reade Fiorella, David Yoo, Albert J Spiotta, Alejandro M J Neurointerv Surg Hemorrhagic Stroke BACKGROUND: Using data from the SMART registry, we report on periprocedural safety of the Penumbra SMART Coil System for endovascular coil embolization of saccular intracranial aneurysms. METHODS: The SMART registry was a prospective, multi-center registry of site standard of care endovascular coiling procedures performed using at least 75% Penumbra SMART Coil, PC400, and/or POD coils. This subset analysis reports on the periprocedural safety outcomes of the saccular intracranial aneurysm cohort. Predictors of rupture/re-rupture or perforation (RRP), thromboembolic complications, and device- or procedure-related adverse events (AEs) were determined in univariate and multivariate analysis. RESULTS: Between June 2016 and August 2018, 851 saccular aneurysm patients (31.0%, 264/851 ruptured) were enrolled across 66 North American centers. Clinically significant (ie, a serious adverse event) RRP occurred in 2.0% (17/851) of cases – 1.9% (5/264) for the ruptured cohort and 2.0% (12/587) for the un-ruptured cohort. Clinically significant thromboembolic events occurred in 3.1% (26/851) of cases – 5.3% (14/264) for the ruptured cohort and 2.0% (12/587) for the un-ruptured cohort. Multivariate predictors of periprocedural RRP were increased packing density and adjunctive treatment with a balloon. For periprocedural thromboembolic events, multivariate predictors were bifurcation location and ruptured status. For device- or procedure-related AEs, multivariate predictors were bifurcation location and adjunctive treatment with stent or balloon. CONCLUSION: The low rates of thromboembolic complications and RRP events demonstrate the adequate safety profile of the SMART Coil System to treat cerebral aneurysms in routine clinical practice. TRIAL REGISTRATION NUMBER: NCT02729740. BMJ Publishing Group 2022-01 2021-02-16 /pmc/articles/PMC8785012/ /pubmed/33593799 http://dx.doi.org/10.1136/neurintsurg-2020-016943 Text en © Author(s) (or their employer(s)) 2022. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) . |
spellingShingle | Hemorrhagic Stroke Starke, Robert M Park, Min S Bellon, Richard Bohnstedt, Bradley Schirmer, Clemens M De Leacy, Reade Fiorella, David Yoo, Albert J Spiotta, Alejandro M Periprocedural safety of saccular aneurysm embolization with the Penumbra SMART Coil System: a SMART registry subset analysis |
title | Periprocedural safety of saccular aneurysm embolization with the Penumbra SMART Coil System: a SMART registry subset analysis |
title_full | Periprocedural safety of saccular aneurysm embolization with the Penumbra SMART Coil System: a SMART registry subset analysis |
title_fullStr | Periprocedural safety of saccular aneurysm embolization with the Penumbra SMART Coil System: a SMART registry subset analysis |
title_full_unstemmed | Periprocedural safety of saccular aneurysm embolization with the Penumbra SMART Coil System: a SMART registry subset analysis |
title_short | Periprocedural safety of saccular aneurysm embolization with the Penumbra SMART Coil System: a SMART registry subset analysis |
title_sort | periprocedural safety of saccular aneurysm embolization with the penumbra smart coil system: a smart registry subset analysis |
topic | Hemorrhagic Stroke |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8785012/ https://www.ncbi.nlm.nih.gov/pubmed/33593799 http://dx.doi.org/10.1136/neurintsurg-2020-016943 |
work_keys_str_mv | AT starkerobertm periproceduralsafetyofsaccularaneurysmembolizationwiththepenumbrasmartcoilsystemasmartregistrysubsetanalysis AT parkmins periproceduralsafetyofsaccularaneurysmembolizationwiththepenumbrasmartcoilsystemasmartregistrysubsetanalysis AT bellonrichard periproceduralsafetyofsaccularaneurysmembolizationwiththepenumbrasmartcoilsystemasmartregistrysubsetanalysis AT bohnstedtbradley periproceduralsafetyofsaccularaneurysmembolizationwiththepenumbrasmartcoilsystemasmartregistrysubsetanalysis AT schirmerclemensm periproceduralsafetyofsaccularaneurysmembolizationwiththepenumbrasmartcoilsystemasmartregistrysubsetanalysis AT deleacyreade periproceduralsafetyofsaccularaneurysmembolizationwiththepenumbrasmartcoilsystemasmartregistrysubsetanalysis AT fiorelladavid periproceduralsafetyofsaccularaneurysmembolizationwiththepenumbrasmartcoilsystemasmartregistrysubsetanalysis AT yooalbertj periproceduralsafetyofsaccularaneurysmembolizationwiththepenumbrasmartcoilsystemasmartregistrysubsetanalysis AT spiottaalejandrom periproceduralsafetyofsaccularaneurysmembolizationwiththepenumbrasmartcoilsystemasmartregistrysubsetanalysis AT periproceduralsafetyofsaccularaneurysmembolizationwiththepenumbrasmartcoilsystemasmartregistrysubsetanalysis |