Cargando…

Apnoeic oxygenation using transnasal humidified rapid-insufflation ventilatory exchange during rigid bronchoscopy: a report of four cases

General anaesthesia with a muscle relaxant is usually performed for rigid bronchoscopy (RB), but ventilation is challenging due to large amounts of leakage. Optiflow™ supplies 100% humidified, warmed oxygen at a rate of up to 70 l/min and this high flow rate may overcome the leakage problem. This ca...

Descripción completa

Detalles Bibliográficos
Autores principales: Jung, Jaewoong, Park, Juhui, Lee, Misoon, Chung, Yang-Hoon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8785317/
https://www.ncbi.nlm.nih.gov/pubmed/35023372
http://dx.doi.org/10.1177/03000605211068309
_version_ 1784638938657325056
author Jung, Jaewoong
Park, Juhui
Lee, Misoon
Chung, Yang-Hoon
author_facet Jung, Jaewoong
Park, Juhui
Lee, Misoon
Chung, Yang-Hoon
author_sort Jung, Jaewoong
collection PubMed
description General anaesthesia with a muscle relaxant is usually performed for rigid bronchoscopy (RB), but ventilation is challenging due to large amounts of leakage. Optiflow™ supplies 100% humidified, warmed oxygen at a rate of up to 70 l/min and this high flow rate may overcome the leakage problem. This case report describes four patients that were scheduled for RB. The lung lesions were all located below the carina, so a bronchial tube was inserted under general anaesthesia. Once a large amount of leakage was confirmed by manual ventilation, Optiflow™ was connected to the bronchial tube (flow rate, 70 l/min). All of the ports of the bronchoscopy were left open to prevent the risk of outlet obstruction. Oxygenation was well maintained with stable vital signs throughout the procedures, which took up to 34 min without airway intervention. There were no occurrences of cardiac arrhythmia or changes in the electrocardiograms. Respiratory acidosis recovered after emergence, which was confirmed by arterial blood gas analysis in all cases. Apnoeic oxygenation using Optiflow™ was applied successfully during RB. Applying Optiflow™ could make cases of difficult ventilation during RB much easier for the anaesthetist. Larger studies need to demonstrate the efficacy and safety of this technique.
format Online
Article
Text
id pubmed-8785317
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-87853172022-01-25 Apnoeic oxygenation using transnasal humidified rapid-insufflation ventilatory exchange during rigid bronchoscopy: a report of four cases Jung, Jaewoong Park, Juhui Lee, Misoon Chung, Yang-Hoon J Int Med Res Case Reports General anaesthesia with a muscle relaxant is usually performed for rigid bronchoscopy (RB), but ventilation is challenging due to large amounts of leakage. Optiflow™ supplies 100% humidified, warmed oxygen at a rate of up to 70 l/min and this high flow rate may overcome the leakage problem. This case report describes four patients that were scheduled for RB. The lung lesions were all located below the carina, so a bronchial tube was inserted under general anaesthesia. Once a large amount of leakage was confirmed by manual ventilation, Optiflow™ was connected to the bronchial tube (flow rate, 70 l/min). All of the ports of the bronchoscopy were left open to prevent the risk of outlet obstruction. Oxygenation was well maintained with stable vital signs throughout the procedures, which took up to 34 min without airway intervention. There were no occurrences of cardiac arrhythmia or changes in the electrocardiograms. Respiratory acidosis recovered after emergence, which was confirmed by arterial blood gas analysis in all cases. Apnoeic oxygenation using Optiflow™ was applied successfully during RB. Applying Optiflow™ could make cases of difficult ventilation during RB much easier for the anaesthetist. Larger studies need to demonstrate the efficacy and safety of this technique. SAGE Publications 2022-01-13 /pmc/articles/PMC8785317/ /pubmed/35023372 http://dx.doi.org/10.1177/03000605211068309 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by-nc/4.0/Creative Commons Non Commercial CC BY-NC: This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Case Reports
Jung, Jaewoong
Park, Juhui
Lee, Misoon
Chung, Yang-Hoon
Apnoeic oxygenation using transnasal humidified rapid-insufflation ventilatory exchange during rigid bronchoscopy: a report of four cases
title Apnoeic oxygenation using transnasal humidified rapid-insufflation ventilatory exchange during rigid bronchoscopy: a report of four cases
title_full Apnoeic oxygenation using transnasal humidified rapid-insufflation ventilatory exchange during rigid bronchoscopy: a report of four cases
title_fullStr Apnoeic oxygenation using transnasal humidified rapid-insufflation ventilatory exchange during rigid bronchoscopy: a report of four cases
title_full_unstemmed Apnoeic oxygenation using transnasal humidified rapid-insufflation ventilatory exchange during rigid bronchoscopy: a report of four cases
title_short Apnoeic oxygenation using transnasal humidified rapid-insufflation ventilatory exchange during rigid bronchoscopy: a report of four cases
title_sort apnoeic oxygenation using transnasal humidified rapid-insufflation ventilatory exchange during rigid bronchoscopy: a report of four cases
topic Case Reports
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8785317/
https://www.ncbi.nlm.nih.gov/pubmed/35023372
http://dx.doi.org/10.1177/03000605211068309
work_keys_str_mv AT jungjaewoong apnoeicoxygenationusingtransnasalhumidifiedrapidinsufflationventilatoryexchangeduringrigidbronchoscopyareportoffourcases
AT parkjuhui apnoeicoxygenationusingtransnasalhumidifiedrapidinsufflationventilatoryexchangeduringrigidbronchoscopyareportoffourcases
AT leemisoon apnoeicoxygenationusingtransnasalhumidifiedrapidinsufflationventilatoryexchangeduringrigidbronchoscopyareportoffourcases
AT chungyanghoon apnoeicoxygenationusingtransnasalhumidifiedrapidinsufflationventilatoryexchangeduringrigidbronchoscopyareportoffourcases