Cargando…

Duplex ultrasound derived maximal systolic acceleration can be a reliable and rapid alternative to ankle brachial pressure indices for the diabetic population with lower extremity arterial disease; a prospective, observational cohort study

Objectives: Ankle brachial pressure index (ABPI) is limited for diabetic patients. This can have costly impacts upon patient's quality of life along with healthcare budgets, with diabetic care equating to approximately 10% of NHS expenditure.(11 ) We aimed to determine whether ultrasound wavefo...

Descripción completa

Detalles Bibliográficos
Autores principales: Williamson, Hannah Michelle, Bartlett, Matthew, Desai, Mital
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8785324/
https://www.ncbi.nlm.nih.gov/pubmed/35083041
http://dx.doi.org/10.1177/20480040211070481
_version_ 1784638941097361408
author Williamson, Hannah Michelle
Bartlett, Matthew
Desai, Mital
author_facet Williamson, Hannah Michelle
Bartlett, Matthew
Desai, Mital
author_sort Williamson, Hannah Michelle
collection PubMed
description Objectives: Ankle brachial pressure index (ABPI) is limited for diabetic patients. This can have costly impacts upon patient's quality of life along with healthcare budgets, with diabetic care equating to approximately 10% of NHS expenditure.(11 ) We aimed to determine whether ultrasound waveform parameters are an alternative for quantifying lower extremity peripheral arterial disease (PAD) where ABPI is unreliable. Design: This was a prospective, observational study. Waveform parameters, systolic rise time (SRT), maximal systolic acceleration (AccMax) and peak systolic velocity (PSV) were recorded at ankle and compared to the ABPI and an aorta-ankle duplex ultrasound scan (DUS) as gold standard. Setting: Measurements were obtained by a Clinical Vascular Scientist at the Royal Free Hospital. Participants: Participants (≥18yrs) with known PAD, but without previous vascular intervention were allocated to non-diabetic control (n = 24) and diabetic test groups (n = 22). Outcome measures: The primary outcome measure was the correlation of novel ultrasound derived indices to PAD severity. The secondary outcome was the efficacy of this correlation in the diabetic population. Results: AccMax was most powerful in detecting PAD in both groups when compared to ABPI in the controls (r = 0.805; p < 0.01) and to DUS in control and test groups (r = −0.633 to −0.643; p < 0.01). In the test group, PSV did not consistently quantify PAD. SRT measurements were inconclusive throughout. Conclusion: AccMax is a rapid alternative tool for diagnosing PAD in diabetic patients. With further research, this simple test may prove useful for monitoring PAD progression in patients unsuitable for ABPI, reducing the need for lengthy repeat duplex scans.
format Online
Article
Text
id pubmed-8785324
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-87853242022-01-25 Duplex ultrasound derived maximal systolic acceleration can be a reliable and rapid alternative to ankle brachial pressure indices for the diabetic population with lower extremity arterial disease; a prospective, observational cohort study Williamson, Hannah Michelle Bartlett, Matthew Desai, Mital JRSM Cardiovasc Dis Applications of waveform analysis in cardiovascular disease- Original Research Article Objectives: Ankle brachial pressure index (ABPI) is limited for diabetic patients. This can have costly impacts upon patient's quality of life along with healthcare budgets, with diabetic care equating to approximately 10% of NHS expenditure.(11 ) We aimed to determine whether ultrasound waveform parameters are an alternative for quantifying lower extremity peripheral arterial disease (PAD) where ABPI is unreliable. Design: This was a prospective, observational study. Waveform parameters, systolic rise time (SRT), maximal systolic acceleration (AccMax) and peak systolic velocity (PSV) were recorded at ankle and compared to the ABPI and an aorta-ankle duplex ultrasound scan (DUS) as gold standard. Setting: Measurements were obtained by a Clinical Vascular Scientist at the Royal Free Hospital. Participants: Participants (≥18yrs) with known PAD, but without previous vascular intervention were allocated to non-diabetic control (n = 24) and diabetic test groups (n = 22). Outcome measures: The primary outcome measure was the correlation of novel ultrasound derived indices to PAD severity. The secondary outcome was the efficacy of this correlation in the diabetic population. Results: AccMax was most powerful in detecting PAD in both groups when compared to ABPI in the controls (r = 0.805; p < 0.01) and to DUS in control and test groups (r = −0.633 to −0.643; p < 0.01). In the test group, PSV did not consistently quantify PAD. SRT measurements were inconclusive throughout. Conclusion: AccMax is a rapid alternative tool for diagnosing PAD in diabetic patients. With further research, this simple test may prove useful for monitoring PAD progression in patients unsuitable for ABPI, reducing the need for lengthy repeat duplex scans. SAGE Publications 2022-01-21 /pmc/articles/PMC8785324/ /pubmed/35083041 http://dx.doi.org/10.1177/20480040211070481 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Applications of waveform analysis in cardiovascular disease- Original Research Article
Williamson, Hannah Michelle
Bartlett, Matthew
Desai, Mital
Duplex ultrasound derived maximal systolic acceleration can be a reliable and rapid alternative to ankle brachial pressure indices for the diabetic population with lower extremity arterial disease; a prospective, observational cohort study
title Duplex ultrasound derived maximal systolic acceleration can be a reliable and rapid alternative to ankle brachial pressure indices for the diabetic population with lower extremity arterial disease; a prospective, observational cohort study
title_full Duplex ultrasound derived maximal systolic acceleration can be a reliable and rapid alternative to ankle brachial pressure indices for the diabetic population with lower extremity arterial disease; a prospective, observational cohort study
title_fullStr Duplex ultrasound derived maximal systolic acceleration can be a reliable and rapid alternative to ankle brachial pressure indices for the diabetic population with lower extremity arterial disease; a prospective, observational cohort study
title_full_unstemmed Duplex ultrasound derived maximal systolic acceleration can be a reliable and rapid alternative to ankle brachial pressure indices for the diabetic population with lower extremity arterial disease; a prospective, observational cohort study
title_short Duplex ultrasound derived maximal systolic acceleration can be a reliable and rapid alternative to ankle brachial pressure indices for the diabetic population with lower extremity arterial disease; a prospective, observational cohort study
title_sort duplex ultrasound derived maximal systolic acceleration can be a reliable and rapid alternative to ankle brachial pressure indices for the diabetic population with lower extremity arterial disease; a prospective, observational cohort study
topic Applications of waveform analysis in cardiovascular disease- Original Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8785324/
https://www.ncbi.nlm.nih.gov/pubmed/35083041
http://dx.doi.org/10.1177/20480040211070481
work_keys_str_mv AT williamsonhannahmichelle duplexultrasoundderivedmaximalsystolicaccelerationcanbeareliableandrapidalternativetoanklebrachialpressureindicesforthediabeticpopulationwithlowerextremityarterialdiseaseaprospectiveobservationalcohortstudy
AT bartlettmatthew duplexultrasoundderivedmaximalsystolicaccelerationcanbeareliableandrapidalternativetoanklebrachialpressureindicesforthediabeticpopulationwithlowerextremityarterialdiseaseaprospectiveobservationalcohortstudy
AT desaimital duplexultrasoundderivedmaximalsystolicaccelerationcanbeareliableandrapidalternativetoanklebrachialpressureindicesforthediabeticpopulationwithlowerextremityarterialdiseaseaprospectiveobservationalcohortstudy