Cargando…

Toward implantable devices for angle-sensitive, lens-less, multifluorescent, single-photon lifetime imaging in the brain using Fabry–Perot and absorptive color filters

Implantable image sensors have the potential to revolutionize neuroscience. Due to their small form factor requirements; however, conventional filters and optics cannot be implemented. These limitations obstruct high-resolution imaging of large neural densities. Recent advances in angle-sensitive im...

Descripción completa

Detalles Bibliográficos
Autores principales: Taal, Adriaan J., Lee, Changhyuk, Choi, Jaebin, Hellenkamp, Björn, Shepard, Kenneth L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8786868/
https://www.ncbi.nlm.nih.gov/pubmed/35075116
http://dx.doi.org/10.1038/s41377-022-00708-9
_version_ 1784639214876360704
author Taal, Adriaan J.
Lee, Changhyuk
Choi, Jaebin
Hellenkamp, Björn
Shepard, Kenneth L.
author_facet Taal, Adriaan J.
Lee, Changhyuk
Choi, Jaebin
Hellenkamp, Björn
Shepard, Kenneth L.
author_sort Taal, Adriaan J.
collection PubMed
description Implantable image sensors have the potential to revolutionize neuroscience. Due to their small form factor requirements; however, conventional filters and optics cannot be implemented. These limitations obstruct high-resolution imaging of large neural densities. Recent advances in angle-sensitive image sensors and single-photon avalanche diodes have provided a path toward ultrathin lens-less fluorescence imaging, enabling plenoptic sensing by extending sensing capabilities to include photon arrival time and incident angle, thereby providing the opportunity for separability of fluorescence point sources within the context of light-field microscopy (LFM). However, the addition of spectral sensitivity to angle-sensitive LFM reduces imager resolution because each wavelength requires a separate pixel subset. Here, we present a 1024-pixel, 50  µm thick implantable shank-based neural imager with color-filter-grating-based angle-sensitive pixels. This angular-spectral sensitive front end combines a metal–insulator–metal (MIM) Fabry–Perot color filter and diffractive optics to produce the measurement of orthogonal light-field information from two distinct colors within a single photodetector. The result is the ability to add independent color sensing to LFM while doubling the effective pixel density. The implantable imager combines angular-spectral and temporal information to demix and localize multispectral fluorescent targets. In this initial prototype, this is demonstrated with 45 μm diameter fluorescently labeled beads in scattering medium. Fluorescent lifetime imaging is exploited to further aid source separation, in addition to detecting pH through lifetime changes in fluorescent dyes. While these initial fluorescent targets are considerably brighter than fluorescently labeled neurons, further improvements will allow the application of these techniques to in-vivo multifluorescent structural and functional neural imaging.
format Online
Article
Text
id pubmed-8786868
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-87868682022-02-07 Toward implantable devices for angle-sensitive, lens-less, multifluorescent, single-photon lifetime imaging in the brain using Fabry–Perot and absorptive color filters Taal, Adriaan J. Lee, Changhyuk Choi, Jaebin Hellenkamp, Björn Shepard, Kenneth L. Light Sci Appl Article Implantable image sensors have the potential to revolutionize neuroscience. Due to their small form factor requirements; however, conventional filters and optics cannot be implemented. These limitations obstruct high-resolution imaging of large neural densities. Recent advances in angle-sensitive image sensors and single-photon avalanche diodes have provided a path toward ultrathin lens-less fluorescence imaging, enabling plenoptic sensing by extending sensing capabilities to include photon arrival time and incident angle, thereby providing the opportunity for separability of fluorescence point sources within the context of light-field microscopy (LFM). However, the addition of spectral sensitivity to angle-sensitive LFM reduces imager resolution because each wavelength requires a separate pixel subset. Here, we present a 1024-pixel, 50  µm thick implantable shank-based neural imager with color-filter-grating-based angle-sensitive pixels. This angular-spectral sensitive front end combines a metal–insulator–metal (MIM) Fabry–Perot color filter and diffractive optics to produce the measurement of orthogonal light-field information from two distinct colors within a single photodetector. The result is the ability to add independent color sensing to LFM while doubling the effective pixel density. The implantable imager combines angular-spectral and temporal information to demix and localize multispectral fluorescent targets. In this initial prototype, this is demonstrated with 45 μm diameter fluorescently labeled beads in scattering medium. Fluorescent lifetime imaging is exploited to further aid source separation, in addition to detecting pH through lifetime changes in fluorescent dyes. While these initial fluorescent targets are considerably brighter than fluorescently labeled neurons, further improvements will allow the application of these techniques to in-vivo multifluorescent structural and functional neural imaging. Nature Publishing Group UK 2022-01-24 /pmc/articles/PMC8786868/ /pubmed/35075116 http://dx.doi.org/10.1038/s41377-022-00708-9 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Taal, Adriaan J.
Lee, Changhyuk
Choi, Jaebin
Hellenkamp, Björn
Shepard, Kenneth L.
Toward implantable devices for angle-sensitive, lens-less, multifluorescent, single-photon lifetime imaging in the brain using Fabry–Perot and absorptive color filters
title Toward implantable devices for angle-sensitive, lens-less, multifluorescent, single-photon lifetime imaging in the brain using Fabry–Perot and absorptive color filters
title_full Toward implantable devices for angle-sensitive, lens-less, multifluorescent, single-photon lifetime imaging in the brain using Fabry–Perot and absorptive color filters
title_fullStr Toward implantable devices for angle-sensitive, lens-less, multifluorescent, single-photon lifetime imaging in the brain using Fabry–Perot and absorptive color filters
title_full_unstemmed Toward implantable devices for angle-sensitive, lens-less, multifluorescent, single-photon lifetime imaging in the brain using Fabry–Perot and absorptive color filters
title_short Toward implantable devices for angle-sensitive, lens-less, multifluorescent, single-photon lifetime imaging in the brain using Fabry–Perot and absorptive color filters
title_sort toward implantable devices for angle-sensitive, lens-less, multifluorescent, single-photon lifetime imaging in the brain using fabry–perot and absorptive color filters
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8786868/
https://www.ncbi.nlm.nih.gov/pubmed/35075116
http://dx.doi.org/10.1038/s41377-022-00708-9
work_keys_str_mv AT taaladriaanj towardimplantabledevicesforanglesensitivelenslessmultifluorescentsinglephotonlifetimeimaginginthebrainusingfabryperotandabsorptivecolorfilters
AT leechanghyuk towardimplantabledevicesforanglesensitivelenslessmultifluorescentsinglephotonlifetimeimaginginthebrainusingfabryperotandabsorptivecolorfilters
AT choijaebin towardimplantabledevicesforanglesensitivelenslessmultifluorescentsinglephotonlifetimeimaginginthebrainusingfabryperotandabsorptivecolorfilters
AT hellenkampbjorn towardimplantabledevicesforanglesensitivelenslessmultifluorescentsinglephotonlifetimeimaginginthebrainusingfabryperotandabsorptivecolorfilters
AT shepardkennethl towardimplantabledevicesforanglesensitivelenslessmultifluorescentsinglephotonlifetimeimaginginthebrainusingfabryperotandabsorptivecolorfilters