Template Matching and Matrix Profile for Signal Quality Assessment of Carotid and Femoral Laser Doppler Vibrometer Signals
Background: Laser-Doppler Vibrometry (LDV) is a laser-based technique that allows measuring the motion of moving targets with high spatial and temporal resolution. To demonstrate its use for the measurement of carotid-femoral pulse wave velocity, a prototype system was employed in a clinical feasibi...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8787261/ https://www.ncbi.nlm.nih.gov/pubmed/35087417 http://dx.doi.org/10.3389/fphys.2021.775052 |
_version_ | 1784639322436141056 |
---|---|
author | Seoni, Silvia Beeckman, Simeon Li, Yanlu Aasmul, Soren Morbiducci, Umberto Baets, Roel Boutouyrie, Pierre Molinari, Filippo Madhu, Nilesh Segers, Patrick |
author_facet | Seoni, Silvia Beeckman, Simeon Li, Yanlu Aasmul, Soren Morbiducci, Umberto Baets, Roel Boutouyrie, Pierre Molinari, Filippo Madhu, Nilesh Segers, Patrick |
author_sort | Seoni, Silvia |
collection | PubMed |
description | Background: Laser-Doppler Vibrometry (LDV) is a laser-based technique that allows measuring the motion of moving targets with high spatial and temporal resolution. To demonstrate its use for the measurement of carotid-femoral pulse wave velocity, a prototype system was employed in a clinical feasibility study. Data were acquired for analysis without prior quality control. Real-time application, however, will require a real-time assessment of signal quality. In this study, we (1) use template matching and matrix profile for assessing the quality of these previously acquired signals; (2) analyze the nature and achievable quality of acquired signals at the carotid and femoral measuring site; (3) explore models for automated classification of signal quality. Methods: Laser-Doppler Vibrometry data were acquired in 100 subjects (50M/50F) and consisted of 4–5 sequences of 20-s recordings of skin displacement, differentiated two times to yield acceleration. Each recording consisted of data from 12 laser beams, yielding 410 carotid-femoral and 407 carotid-carotid recordings. Data quality was visually assessed on a 1–5 scale, and a subset of best quality data was used to construct an acceleration template for both measuring sites. The time-varying cross-correlation of the acceleration signals with the template was computed. A quality metric constructed on several features of this template matching was derived. Next, the matrix-profile technique was applied to identify recurring features in the measured time series and derived a similar quality metric. The statistical distribution of the metrics, and their correlates with basic clinical data were assessed. Finally, logistic-regression-based classifiers were developed and their ability to automatically classify LDV-signal quality was assessed. Results: Automated quality metrics correlated well with visual scores. Signal quality was negatively correlated with BMI for femoral recordings but not for carotid recordings. Logistic regression models based on both methods yielded an accuracy of minimally 80% for our carotid and femoral recording data, reaching 87% for the femoral data. Conclusion: Both template matching and matrix profile were found suitable methods for automated grading of LDV signal quality and were able to generate a quality metric that was on par with the signal quality assessment of the expert. The classifiers, developed with both quality metrics, showed their potential for future real-time implementation. |
format | Online Article Text |
id | pubmed-8787261 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-87872612022-01-26 Template Matching and Matrix Profile for Signal Quality Assessment of Carotid and Femoral Laser Doppler Vibrometer Signals Seoni, Silvia Beeckman, Simeon Li, Yanlu Aasmul, Soren Morbiducci, Umberto Baets, Roel Boutouyrie, Pierre Molinari, Filippo Madhu, Nilesh Segers, Patrick Front Physiol Physiology Background: Laser-Doppler Vibrometry (LDV) is a laser-based technique that allows measuring the motion of moving targets with high spatial and temporal resolution. To demonstrate its use for the measurement of carotid-femoral pulse wave velocity, a prototype system was employed in a clinical feasibility study. Data were acquired for analysis without prior quality control. Real-time application, however, will require a real-time assessment of signal quality. In this study, we (1) use template matching and matrix profile for assessing the quality of these previously acquired signals; (2) analyze the nature and achievable quality of acquired signals at the carotid and femoral measuring site; (3) explore models for automated classification of signal quality. Methods: Laser-Doppler Vibrometry data were acquired in 100 subjects (50M/50F) and consisted of 4–5 sequences of 20-s recordings of skin displacement, differentiated two times to yield acceleration. Each recording consisted of data from 12 laser beams, yielding 410 carotid-femoral and 407 carotid-carotid recordings. Data quality was visually assessed on a 1–5 scale, and a subset of best quality data was used to construct an acceleration template for both measuring sites. The time-varying cross-correlation of the acceleration signals with the template was computed. A quality metric constructed on several features of this template matching was derived. Next, the matrix-profile technique was applied to identify recurring features in the measured time series and derived a similar quality metric. The statistical distribution of the metrics, and their correlates with basic clinical data were assessed. Finally, logistic-regression-based classifiers were developed and their ability to automatically classify LDV-signal quality was assessed. Results: Automated quality metrics correlated well with visual scores. Signal quality was negatively correlated with BMI for femoral recordings but not for carotid recordings. Logistic regression models based on both methods yielded an accuracy of minimally 80% for our carotid and femoral recording data, reaching 87% for the femoral data. Conclusion: Both template matching and matrix profile were found suitable methods for automated grading of LDV signal quality and were able to generate a quality metric that was on par with the signal quality assessment of the expert. The classifiers, developed with both quality metrics, showed their potential for future real-time implementation. Frontiers Media S.A. 2022-01-11 /pmc/articles/PMC8787261/ /pubmed/35087417 http://dx.doi.org/10.3389/fphys.2021.775052 Text en Copyright © 2022 Seoni, Beeckman, Li, Aasmul, Morbiducci, Baets, Boutouyrie, Molinari, Madhu and Segers. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Physiology Seoni, Silvia Beeckman, Simeon Li, Yanlu Aasmul, Soren Morbiducci, Umberto Baets, Roel Boutouyrie, Pierre Molinari, Filippo Madhu, Nilesh Segers, Patrick Template Matching and Matrix Profile for Signal Quality Assessment of Carotid and Femoral Laser Doppler Vibrometer Signals |
title | Template Matching and Matrix Profile for Signal Quality Assessment of Carotid and Femoral Laser Doppler Vibrometer Signals |
title_full | Template Matching and Matrix Profile for Signal Quality Assessment of Carotid and Femoral Laser Doppler Vibrometer Signals |
title_fullStr | Template Matching and Matrix Profile for Signal Quality Assessment of Carotid and Femoral Laser Doppler Vibrometer Signals |
title_full_unstemmed | Template Matching and Matrix Profile for Signal Quality Assessment of Carotid and Femoral Laser Doppler Vibrometer Signals |
title_short | Template Matching and Matrix Profile for Signal Quality Assessment of Carotid and Femoral Laser Doppler Vibrometer Signals |
title_sort | template matching and matrix profile for signal quality assessment of carotid and femoral laser doppler vibrometer signals |
topic | Physiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8787261/ https://www.ncbi.nlm.nih.gov/pubmed/35087417 http://dx.doi.org/10.3389/fphys.2021.775052 |
work_keys_str_mv | AT seonisilvia templatematchingandmatrixprofileforsignalqualityassessmentofcarotidandfemorallaserdopplervibrometersignals AT beeckmansimeon templatematchingandmatrixprofileforsignalqualityassessmentofcarotidandfemorallaserdopplervibrometersignals AT liyanlu templatematchingandmatrixprofileforsignalqualityassessmentofcarotidandfemorallaserdopplervibrometersignals AT aasmulsoren templatematchingandmatrixprofileforsignalqualityassessmentofcarotidandfemorallaserdopplervibrometersignals AT morbiducciumberto templatematchingandmatrixprofileforsignalqualityassessmentofcarotidandfemorallaserdopplervibrometersignals AT baetsroel templatematchingandmatrixprofileforsignalqualityassessmentofcarotidandfemorallaserdopplervibrometersignals AT boutouyriepierre templatematchingandmatrixprofileforsignalqualityassessmentofcarotidandfemorallaserdopplervibrometersignals AT molinarifilippo templatematchingandmatrixprofileforsignalqualityassessmentofcarotidandfemorallaserdopplervibrometersignals AT madhunilesh templatematchingandmatrixprofileforsignalqualityassessmentofcarotidandfemorallaserdopplervibrometersignals AT segerspatrick templatematchingandmatrixprofileforsignalqualityassessmentofcarotidandfemorallaserdopplervibrometersignals |