Cargando…
Magnetic Resonance Imaging of the Knee in the Presence of Bridging External Fixation: A Comparative Experimental Evaluation of Four External Fixators, Including Dolphix(®)
Performing MR investigation on patients instrumented with external fixators is still controversial. The aim of this study is to evaluate the quality of MR imaging of the knee structures in the presence of bridging external fixators. Different cadaveric lower limbs were instrumented with the MR-condi...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8788467/ https://www.ncbi.nlm.nih.gov/pubmed/35076530 http://dx.doi.org/10.3390/jfmk7010004 |
_version_ | 1784639571547389952 |
---|---|
author | Addevico, Francesco Simoncini, Alberto Solitro, Giovanni Morandi, Massimo Max |
author_facet | Addevico, Francesco Simoncini, Alberto Solitro, Giovanni Morandi, Massimo Max |
author_sort | Addevico, Francesco |
collection | PubMed |
description | Performing MR investigation on patients instrumented with external fixators is still controversial. The aim of this study is to evaluate the quality of MR imaging of the knee structures in the presence of bridging external fixators. Different cadaveric lower limbs were instrumented with the MR-conditional external fixators Hofmann III (Stryker, Kalamazoo, MI, USA), Large external Fixator (DePuy Synthes, Raynham, MA, USA), XtraFix (Zymmer, Warsaw, IN, USA) and a newer implant of Ketron Peek CA30 and ERGAL 7075 pins, Dolphix(®), (Citieffe, Bologna, Italy). The specimens were MR scanned before and after the instrumentation. The images were subjectively judged by a pool of blinded radiologists and then quantitatively evaluated calculating signal intensity, signal to noise and contrast to noise in the five regions of interest. The area of distortion due to the presence of metallic pins was calculated. All the images were considered equally useful for diagnosis with no differences between devices (p > 0.05). Only few differences in the quantification of images have been detected between groups while the presence of metallic components was the main limit of the procedure. The mean length of the radius of the area of distortion of the pins were 53.17 ± 8.19 mm, 45.07 ± 4.33 mm, 17 ± 5.4 mm and 37.12 ± 10.17 mm per pins provided by Zimmer, Synthes, Citieffe and Stryker, respectively (p = 0.041). The implant of Ketron Peek CA30 and ERGAL 7075 pins showed the smallest distortion area. |
format | Online Article Text |
id | pubmed-8788467 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-87884672022-01-26 Magnetic Resonance Imaging of the Knee in the Presence of Bridging External Fixation: A Comparative Experimental Evaluation of Four External Fixators, Including Dolphix(®) Addevico, Francesco Simoncini, Alberto Solitro, Giovanni Morandi, Massimo Max J Funct Morphol Kinesiol Article Performing MR investigation on patients instrumented with external fixators is still controversial. The aim of this study is to evaluate the quality of MR imaging of the knee structures in the presence of bridging external fixators. Different cadaveric lower limbs were instrumented with the MR-conditional external fixators Hofmann III (Stryker, Kalamazoo, MI, USA), Large external Fixator (DePuy Synthes, Raynham, MA, USA), XtraFix (Zymmer, Warsaw, IN, USA) and a newer implant of Ketron Peek CA30 and ERGAL 7075 pins, Dolphix(®), (Citieffe, Bologna, Italy). The specimens were MR scanned before and after the instrumentation. The images were subjectively judged by a pool of blinded radiologists and then quantitatively evaluated calculating signal intensity, signal to noise and contrast to noise in the five regions of interest. The area of distortion due to the presence of metallic pins was calculated. All the images were considered equally useful for diagnosis with no differences between devices (p > 0.05). Only few differences in the quantification of images have been detected between groups while the presence of metallic components was the main limit of the procedure. The mean length of the radius of the area of distortion of the pins were 53.17 ± 8.19 mm, 45.07 ± 4.33 mm, 17 ± 5.4 mm and 37.12 ± 10.17 mm per pins provided by Zimmer, Synthes, Citieffe and Stryker, respectively (p = 0.041). The implant of Ketron Peek CA30 and ERGAL 7075 pins showed the smallest distortion area. MDPI 2021-12-30 /pmc/articles/PMC8788467/ /pubmed/35076530 http://dx.doi.org/10.3390/jfmk7010004 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Addevico, Francesco Simoncini, Alberto Solitro, Giovanni Morandi, Massimo Max Magnetic Resonance Imaging of the Knee in the Presence of Bridging External Fixation: A Comparative Experimental Evaluation of Four External Fixators, Including Dolphix(®) |
title | Magnetic Resonance Imaging of the Knee in the Presence of Bridging External Fixation: A Comparative Experimental Evaluation of Four External Fixators, Including Dolphix(®) |
title_full | Magnetic Resonance Imaging of the Knee in the Presence of Bridging External Fixation: A Comparative Experimental Evaluation of Four External Fixators, Including Dolphix(®) |
title_fullStr | Magnetic Resonance Imaging of the Knee in the Presence of Bridging External Fixation: A Comparative Experimental Evaluation of Four External Fixators, Including Dolphix(®) |
title_full_unstemmed | Magnetic Resonance Imaging of the Knee in the Presence of Bridging External Fixation: A Comparative Experimental Evaluation of Four External Fixators, Including Dolphix(®) |
title_short | Magnetic Resonance Imaging of the Knee in the Presence of Bridging External Fixation: A Comparative Experimental Evaluation of Four External Fixators, Including Dolphix(®) |
title_sort | magnetic resonance imaging of the knee in the presence of bridging external fixation: a comparative experimental evaluation of four external fixators, including dolphix(®) |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8788467/ https://www.ncbi.nlm.nih.gov/pubmed/35076530 http://dx.doi.org/10.3390/jfmk7010004 |
work_keys_str_mv | AT addevicofrancesco magneticresonanceimagingofthekneeinthepresenceofbridgingexternalfixationacomparativeexperimentalevaluationoffourexternalfixatorsincludingdolphix AT simoncinialberto magneticresonanceimagingofthekneeinthepresenceofbridgingexternalfixationacomparativeexperimentalevaluationoffourexternalfixatorsincludingdolphix AT solitrogiovanni magneticresonanceimagingofthekneeinthepresenceofbridgingexternalfixationacomparativeexperimentalevaluationoffourexternalfixatorsincludingdolphix AT morandimassimomax magneticresonanceimagingofthekneeinthepresenceofbridgingexternalfixationacomparativeexperimentalevaluationoffourexternalfixatorsincludingdolphix |