Vitamin E infused highly cross-linked cemented cups in total hip arthroplasty show good wear pattern and stabilize satisfactorily: a randomized, controlled RSA trial with 5-year follow-up
BACKGROUND AND PURPOSE: Vitamin E infused highly cross-linked polyethylene (VEPE) was introduced in order to enhance oxidative resistance in highly cross-linked polyethylene cups in total hip arthroplasty (THA). We have, with a follow-up of 5 years, evaluated wear characteristics of 2 identically de...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medical Journals Sweden, on behalf of the Nordic Orthopedic Federation
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8788680/ https://www.ncbi.nlm.nih.gov/pubmed/35048993 http://dx.doi.org/10.2340/17453674.2022.1517 |
_version_ | 1784639613317414912 |
---|---|
author | BERGVINSSON, Halldor ZAMPELIS, Vasilis SUNDBERG, Martin TJÖRNSTRAND, Jon FLIVIK, Gunnar |
author_facet | BERGVINSSON, Halldor ZAMPELIS, Vasilis SUNDBERG, Martin TJÖRNSTRAND, Jon FLIVIK, Gunnar |
author_sort | BERGVINSSON, Halldor |
collection | PubMed |
description | BACKGROUND AND PURPOSE: Vitamin E infused highly cross-linked polyethylene (VEPE) was introduced in order to enhance oxidative resistance in highly cross-linked polyethylene cups in total hip arthroplasty (THA). We have, with a follow-up of 5 years, evaluated wear characteristics of 2 identically designed cemented cups with the only difference being the material, VEPE or ultra-high molecular weight polyethylene (UHMWPE). Furthermore, we report cup migration and clinical outcome. PATIENTS AND METHODS: 48 patients with primary osteoarthritis were randomized to either UHMWPE or VEPE cups. Patients were followed with radiostereometric analysis (RSA) from the first postoperative day, at 3 months, 1, 2, and 5 years as well as with hip-specific outcome questionnaires. RESULTS: At 3 months the mean proximal head penetration for UHMWPE was 0.07 mm (95% CI 0.03–0.11) and for VEPE 0.06 mm (–0.01 to 0.13). Thereafter, there was a continuous annual wear of 0.08 mm/year, up to 0.46 mm (0.36–0.57) at 5 years, for the UHMWPE cup. The VEPE cup showed low annual wear of 0.01 mm/year, up to 0.09 mm (0.02–0.16) at 5 years. In the first 3 months the UHMWPE cup migrated cranially 0.08 mm (0.03–0.13) whereas the VEPE cup migrated 0.17 mm (0.10–0.24), Thereafter, they showed similar migration patterns with stabilization between 2 and 5 years up to 0.21 mm (0.04–0.39) and 0.24 mm (0.13–0.36) respectively. The HOOS remained good up to 5 years, and no cup was revised. INTERPRETATION: Compared with otherwise identical UHMWPE cups the cemented VEPE cup shows statistically significant reduction of wear up to 5 years and both cup types stabilize well with good clinical outcome. |
format | Online Article Text |
id | pubmed-8788680 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Medical Journals Sweden, on behalf of the Nordic Orthopedic Federation |
record_format | MEDLINE/PubMed |
spelling | pubmed-87886802022-02-16 Vitamin E infused highly cross-linked cemented cups in total hip arthroplasty show good wear pattern and stabilize satisfactorily: a randomized, controlled RSA trial with 5-year follow-up BERGVINSSON, Halldor ZAMPELIS, Vasilis SUNDBERG, Martin TJÖRNSTRAND, Jon FLIVIK, Gunnar Acta Orthop Article BACKGROUND AND PURPOSE: Vitamin E infused highly cross-linked polyethylene (VEPE) was introduced in order to enhance oxidative resistance in highly cross-linked polyethylene cups in total hip arthroplasty (THA). We have, with a follow-up of 5 years, evaluated wear characteristics of 2 identically designed cemented cups with the only difference being the material, VEPE or ultra-high molecular weight polyethylene (UHMWPE). Furthermore, we report cup migration and clinical outcome. PATIENTS AND METHODS: 48 patients with primary osteoarthritis were randomized to either UHMWPE or VEPE cups. Patients were followed with radiostereometric analysis (RSA) from the first postoperative day, at 3 months, 1, 2, and 5 years as well as with hip-specific outcome questionnaires. RESULTS: At 3 months the mean proximal head penetration for UHMWPE was 0.07 mm (95% CI 0.03–0.11) and for VEPE 0.06 mm (–0.01 to 0.13). Thereafter, there was a continuous annual wear of 0.08 mm/year, up to 0.46 mm (0.36–0.57) at 5 years, for the UHMWPE cup. The VEPE cup showed low annual wear of 0.01 mm/year, up to 0.09 mm (0.02–0.16) at 5 years. In the first 3 months the UHMWPE cup migrated cranially 0.08 mm (0.03–0.13) whereas the VEPE cup migrated 0.17 mm (0.10–0.24), Thereafter, they showed similar migration patterns with stabilization between 2 and 5 years up to 0.21 mm (0.04–0.39) and 0.24 mm (0.13–0.36) respectively. The HOOS remained good up to 5 years, and no cup was revised. INTERPRETATION: Compared with otherwise identical UHMWPE cups the cemented VEPE cup shows statistically significant reduction of wear up to 5 years and both cup types stabilize well with good clinical outcome. Medical Journals Sweden, on behalf of the Nordic Orthopedic Federation 2022-01-20 /pmc/articles/PMC8788680/ /pubmed/35048993 http://dx.doi.org/10.2340/17453674.2022.1517 Text en © 2022 The Author(s) https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (https://creativecommons.org/licenses/by-nc/4.0/), allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material for non-commercial purposes, provided proper attribution to the original work. |
spellingShingle | Article BERGVINSSON, Halldor ZAMPELIS, Vasilis SUNDBERG, Martin TJÖRNSTRAND, Jon FLIVIK, Gunnar Vitamin E infused highly cross-linked cemented cups in total hip arthroplasty show good wear pattern and stabilize satisfactorily: a randomized, controlled RSA trial with 5-year follow-up |
title | Vitamin E infused highly cross-linked cemented cups in total hip arthroplasty show good wear pattern and stabilize satisfactorily: a randomized, controlled RSA trial with 5-year follow-up |
title_full | Vitamin E infused highly cross-linked cemented cups in total hip arthroplasty show good wear pattern and stabilize satisfactorily: a randomized, controlled RSA trial with 5-year follow-up |
title_fullStr | Vitamin E infused highly cross-linked cemented cups in total hip arthroplasty show good wear pattern and stabilize satisfactorily: a randomized, controlled RSA trial with 5-year follow-up |
title_full_unstemmed | Vitamin E infused highly cross-linked cemented cups in total hip arthroplasty show good wear pattern and stabilize satisfactorily: a randomized, controlled RSA trial with 5-year follow-up |
title_short | Vitamin E infused highly cross-linked cemented cups in total hip arthroplasty show good wear pattern and stabilize satisfactorily: a randomized, controlled RSA trial with 5-year follow-up |
title_sort | vitamin e infused highly cross-linked cemented cups in total hip arthroplasty show good wear pattern and stabilize satisfactorily: a randomized, controlled rsa trial with 5-year follow-up |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8788680/ https://www.ncbi.nlm.nih.gov/pubmed/35048993 http://dx.doi.org/10.2340/17453674.2022.1517 |
work_keys_str_mv | AT bergvinssonhalldor vitamineinfusedhighlycrosslinkedcementedcupsintotalhiparthroplastyshowgoodwearpatternandstabilizesatisfactorilyarandomizedcontrolledrsatrialwith5yearfollowup AT zampelisvasilis vitamineinfusedhighlycrosslinkedcementedcupsintotalhiparthroplastyshowgoodwearpatternandstabilizesatisfactorilyarandomizedcontrolledrsatrialwith5yearfollowup AT sundbergmartin vitamineinfusedhighlycrosslinkedcementedcupsintotalhiparthroplastyshowgoodwearpatternandstabilizesatisfactorilyarandomizedcontrolledrsatrialwith5yearfollowup AT tjornstrandjon vitamineinfusedhighlycrosslinkedcementedcupsintotalhiparthroplastyshowgoodwearpatternandstabilizesatisfactorilyarandomizedcontrolledrsatrialwith5yearfollowup AT flivikgunnar vitamineinfusedhighlycrosslinkedcementedcupsintotalhiparthroplastyshowgoodwearpatternandstabilizesatisfactorilyarandomizedcontrolledrsatrialwith5yearfollowup |