Cargando…

Dynamic platelet function: A novel biomarker in inflammatory arthritis?

BACKGROUND: Patients with inflammatory arthritis die prematurely of cardiovascular disease. Inflammation activates platelets. Since treatment of inflammatory arthritis is associated with reduced mortality, and decreased platelet reactivity reduces cardiovascular events, we hypothesised that platelet...

Descripción completa

Detalles Bibliográficos
Autores principales: Nic an Riogh, Eithne, Dunne, Eimear, Cowley, Sharon, Leamy, Kelly, McCarthy, Geraldine, Kenny, Dermot, Stack, John
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8789097/
https://www.ncbi.nlm.nih.gov/pubmed/35077469
http://dx.doi.org/10.1371/journal.pone.0261825
_version_ 1784639691183620096
author Nic an Riogh, Eithne
Dunne, Eimear
Cowley, Sharon
Leamy, Kelly
McCarthy, Geraldine
Kenny, Dermot
Stack, John
author_facet Nic an Riogh, Eithne
Dunne, Eimear
Cowley, Sharon
Leamy, Kelly
McCarthy, Geraldine
Kenny, Dermot
Stack, John
author_sort Nic an Riogh, Eithne
collection PubMed
description BACKGROUND: Patients with inflammatory arthritis die prematurely of cardiovascular disease. Inflammation activates platelets. Since treatment of inflammatory arthritis is associated with reduced mortality, and decreased platelet reactivity reduces cardiovascular events, we hypothesised that platelet reactivity as measured by dynamic platelet function (DPF) would be increased in patients with inflammatory arthritis and that reactivity could be reduced with therapeutic intervention. OBJECTIVES: To characterise platelet function using a validated physiological assay in patients with inflammatory arthritis before and after disease improvement. METHODS: 22 patients were recruited and treated as per local protocol. DPF was measured at baseline and after clinical improvement. Video microscopy was utilised to measure dynamic platelet behaviour in microliters of blood perfused over von Willebrand factor (VWF) at arterial shear rates (1500 s-1). Motion-analysis software measured the number of platelets interacting with VWF, translocating across VWF, the speed and distance platelets travelled across VWF, and stably adhering to the surface. Platelet parameters at baseline and following improvement were compared using Wilcoxon signed rank test and paired student t-test. Changes in platelet function were correlated to inflammatory disease markers by Pearson Correlation. RESULTS: 18 patients completed the study. Platelet adhesion decreased and platelet motion increased following treatment. Tender joint count correlated with platelet adhesion (Pearson r = 0.616, p≤0.01) while CRP correlated with velocity of platelet movement (Pearson r = 0.563, p≤0.01). CONCLUSIONS: Improvement in clinical markers of inflammation is associated with a corresponding change in platelet function. Given the association between reduced mortality and decreased platelet reactivity our results suggest that an appropriate assay of platelet function could guide future therapy of patients with inflammatory arthritis.
format Online
Article
Text
id pubmed-8789097
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-87890972022-01-26 Dynamic platelet function: A novel biomarker in inflammatory arthritis? Nic an Riogh, Eithne Dunne, Eimear Cowley, Sharon Leamy, Kelly McCarthy, Geraldine Kenny, Dermot Stack, John PLoS One Research Article BACKGROUND: Patients with inflammatory arthritis die prematurely of cardiovascular disease. Inflammation activates platelets. Since treatment of inflammatory arthritis is associated with reduced mortality, and decreased platelet reactivity reduces cardiovascular events, we hypothesised that platelet reactivity as measured by dynamic platelet function (DPF) would be increased in patients with inflammatory arthritis and that reactivity could be reduced with therapeutic intervention. OBJECTIVES: To characterise platelet function using a validated physiological assay in patients with inflammatory arthritis before and after disease improvement. METHODS: 22 patients were recruited and treated as per local protocol. DPF was measured at baseline and after clinical improvement. Video microscopy was utilised to measure dynamic platelet behaviour in microliters of blood perfused over von Willebrand factor (VWF) at arterial shear rates (1500 s-1). Motion-analysis software measured the number of platelets interacting with VWF, translocating across VWF, the speed and distance platelets travelled across VWF, and stably adhering to the surface. Platelet parameters at baseline and following improvement were compared using Wilcoxon signed rank test and paired student t-test. Changes in platelet function were correlated to inflammatory disease markers by Pearson Correlation. RESULTS: 18 patients completed the study. Platelet adhesion decreased and platelet motion increased following treatment. Tender joint count correlated with platelet adhesion (Pearson r = 0.616, p≤0.01) while CRP correlated with velocity of platelet movement (Pearson r = 0.563, p≤0.01). CONCLUSIONS: Improvement in clinical markers of inflammation is associated with a corresponding change in platelet function. Given the association between reduced mortality and decreased platelet reactivity our results suggest that an appropriate assay of platelet function could guide future therapy of patients with inflammatory arthritis. Public Library of Science 2022-01-25 /pmc/articles/PMC8789097/ /pubmed/35077469 http://dx.doi.org/10.1371/journal.pone.0261825 Text en © 2022 Nic an Riogh et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Nic an Riogh, Eithne
Dunne, Eimear
Cowley, Sharon
Leamy, Kelly
McCarthy, Geraldine
Kenny, Dermot
Stack, John
Dynamic platelet function: A novel biomarker in inflammatory arthritis?
title Dynamic platelet function: A novel biomarker in inflammatory arthritis?
title_full Dynamic platelet function: A novel biomarker in inflammatory arthritis?
title_fullStr Dynamic platelet function: A novel biomarker in inflammatory arthritis?
title_full_unstemmed Dynamic platelet function: A novel biomarker in inflammatory arthritis?
title_short Dynamic platelet function: A novel biomarker in inflammatory arthritis?
title_sort dynamic platelet function: a novel biomarker in inflammatory arthritis?
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8789097/
https://www.ncbi.nlm.nih.gov/pubmed/35077469
http://dx.doi.org/10.1371/journal.pone.0261825
work_keys_str_mv AT nicanriogheithne dynamicplateletfunctionanovelbiomarkerininflammatoryarthritis
AT dunneeimear dynamicplateletfunctionanovelbiomarkerininflammatoryarthritis
AT cowleysharon dynamicplateletfunctionanovelbiomarkerininflammatoryarthritis
AT leamykelly dynamicplateletfunctionanovelbiomarkerininflammatoryarthritis
AT mccarthygeraldine dynamicplateletfunctionanovelbiomarkerininflammatoryarthritis
AT kennydermot dynamicplateletfunctionanovelbiomarkerininflammatoryarthritis
AT stackjohn dynamicplateletfunctionanovelbiomarkerininflammatoryarthritis