Cargando…
Fluid-solid-heat coupling deformation analysis of the valve trims in a multistage pressure reducing valve
A multistage pressure reducing valve with specially designed pressure reducing components is presented in this paper. As the deformation of the valve trims under fluid-solid-heat coupling has an important influence on the operation reliability of the valve, a numerical simulation is carried out to a...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8789176/ https://www.ncbi.nlm.nih.gov/pubmed/35077526 http://dx.doi.org/10.1371/journal.pone.0263076 |
Sumario: | A multistage pressure reducing valve with specially designed pressure reducing components is presented in this paper. As the deformation of the valve trims under fluid-solid-heat coupling has an important influence on the operation reliability of the valve, a numerical simulation is carried out to analyse the flow field characteristic in the valve and radial deformation of the valve trims using the ANSYS software. And a deformation experiment is designed to validate the deformations of the valve trims at high temperature of 693.15 K. The results indicate that the simulation results agree well with the experimental data. Moreover, it is found that the temperature field has the most significant influence on the deformation of the valve trims, the radial deformations of the matching surface vary from 0.439 to 0.442 mm. And the radial deformations caused by other factors vary from 0.005 to 0.015 mm. In addition, as a novel indicator, the clearance after deformation of the matching surface is used to evaluate the operation reliability of the valve. By using the GAP function in ANSYS static module, the clearances of the matching surface are obtained at different openings under the condition of fluid-solid-heat coupling, further indicating that the initial clearance between the valve plug and inner sleeve should be greater than 0.014 mm to ensure the operation reliability of the valve. |
---|