Cargando…
Dosimetry of heavy ion exposure to human cells using nanoscopic imaging of double strand break repair protein clusters
The human body is constantly exposed to ionizing radiation of different qualities. Especially the exposure to high-LET (linear energy transfer) particles increases due to new tumor therapy methods using e.g. carbon ions. Furthermore, upon radiation accidents, a mixture of radiation of different qual...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8789836/ https://www.ncbi.nlm.nih.gov/pubmed/35079078 http://dx.doi.org/10.1038/s41598-022-05413-6 |
_version_ | 1784639863223484416 |
---|---|
author | Reindl, Judith Kundrat, P. Girst, S. Sammer, M. Schwarz, B. Dollinger, G. |
author_facet | Reindl, Judith Kundrat, P. Girst, S. Sammer, M. Schwarz, B. Dollinger, G. |
author_sort | Reindl, Judith |
collection | PubMed |
description | The human body is constantly exposed to ionizing radiation of different qualities. Especially the exposure to high-LET (linear energy transfer) particles increases due to new tumor therapy methods using e.g. carbon ions. Furthermore, upon radiation accidents, a mixture of radiation of different quality is adding up to human radiation exposure. Finally, long-term space missions such as the mission to mars pose great challenges to the dose assessment an astronaut was exposed to. Currently, DSB counting using γH2AX foci is used as an exact dosimetric measure for individuals. Due to the size of the γH2AX IRIF of ~ 0.6 µm, it is only possible to count DSB when they are separated by this distance. For high-LET particle exposure, the distance of the DSB is too small to be separated and the dose will be underestimated. In this study, we developed a method where it is possible to count DSB which are separated by a distance of ~ 140 nm. We counted the number of ionizing radiation-induced pDNA-PKcs (DNA-PKcs phosphorylated at T2609) foci (size = 140 nm ± 20 nm) in human HeLa cells using STED super-resolution microscopy that has an intrinsic resolution of 100 nm. Irradiation was performed at the ion microprobe SNAKE using high-LET 20 MeV lithium (LET = 116 keV/µm) and 27 MeV carbon ions (LET = 500 keV/µm). pDNA-PKcs foci label all DSB as proven by counterstaining with 53BP1 after low-LET γ-irradiation where separation of individual DSB is in most cases larger than the 53BP1 gross size of about 0.6 µm. Lithium ions produce (1.5 ± 0.1) IRIF/µm track length, for carbon ions (2.2 ± 0.2) IRIF/µm are counted. These values are enhanced by a factor of 2–3 compared to conventional foci counting of high-LET tracks. Comparison of the measurements to PARTRAC simulation data proof the consistency of results. We used these data to develop a measure for dosimetry of high-LET or mixed particle radiation exposure directly in the biological sample. We show that proper dosimetry for radiation up to a LET of 240 keV/µm is possible. |
format | Online Article Text |
id | pubmed-8789836 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-87898362022-01-27 Dosimetry of heavy ion exposure to human cells using nanoscopic imaging of double strand break repair protein clusters Reindl, Judith Kundrat, P. Girst, S. Sammer, M. Schwarz, B. Dollinger, G. Sci Rep Article The human body is constantly exposed to ionizing radiation of different qualities. Especially the exposure to high-LET (linear energy transfer) particles increases due to new tumor therapy methods using e.g. carbon ions. Furthermore, upon radiation accidents, a mixture of radiation of different quality is adding up to human radiation exposure. Finally, long-term space missions such as the mission to mars pose great challenges to the dose assessment an astronaut was exposed to. Currently, DSB counting using γH2AX foci is used as an exact dosimetric measure for individuals. Due to the size of the γH2AX IRIF of ~ 0.6 µm, it is only possible to count DSB when they are separated by this distance. For high-LET particle exposure, the distance of the DSB is too small to be separated and the dose will be underestimated. In this study, we developed a method where it is possible to count DSB which are separated by a distance of ~ 140 nm. We counted the number of ionizing radiation-induced pDNA-PKcs (DNA-PKcs phosphorylated at T2609) foci (size = 140 nm ± 20 nm) in human HeLa cells using STED super-resolution microscopy that has an intrinsic resolution of 100 nm. Irradiation was performed at the ion microprobe SNAKE using high-LET 20 MeV lithium (LET = 116 keV/µm) and 27 MeV carbon ions (LET = 500 keV/µm). pDNA-PKcs foci label all DSB as proven by counterstaining with 53BP1 after low-LET γ-irradiation where separation of individual DSB is in most cases larger than the 53BP1 gross size of about 0.6 µm. Lithium ions produce (1.5 ± 0.1) IRIF/µm track length, for carbon ions (2.2 ± 0.2) IRIF/µm are counted. These values are enhanced by a factor of 2–3 compared to conventional foci counting of high-LET tracks. Comparison of the measurements to PARTRAC simulation data proof the consistency of results. We used these data to develop a measure for dosimetry of high-LET or mixed particle radiation exposure directly in the biological sample. We show that proper dosimetry for radiation up to a LET of 240 keV/µm is possible. Nature Publishing Group UK 2022-01-25 /pmc/articles/PMC8789836/ /pubmed/35079078 http://dx.doi.org/10.1038/s41598-022-05413-6 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Reindl, Judith Kundrat, P. Girst, S. Sammer, M. Schwarz, B. Dollinger, G. Dosimetry of heavy ion exposure to human cells using nanoscopic imaging of double strand break repair protein clusters |
title | Dosimetry of heavy ion exposure to human cells using nanoscopic imaging of double strand break repair protein clusters |
title_full | Dosimetry of heavy ion exposure to human cells using nanoscopic imaging of double strand break repair protein clusters |
title_fullStr | Dosimetry of heavy ion exposure to human cells using nanoscopic imaging of double strand break repair protein clusters |
title_full_unstemmed | Dosimetry of heavy ion exposure to human cells using nanoscopic imaging of double strand break repair protein clusters |
title_short | Dosimetry of heavy ion exposure to human cells using nanoscopic imaging of double strand break repair protein clusters |
title_sort | dosimetry of heavy ion exposure to human cells using nanoscopic imaging of double strand break repair protein clusters |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8789836/ https://www.ncbi.nlm.nih.gov/pubmed/35079078 http://dx.doi.org/10.1038/s41598-022-05413-6 |
work_keys_str_mv | AT reindljudith dosimetryofheavyionexposuretohumancellsusingnanoscopicimagingofdoublestrandbreakrepairproteinclusters AT kundratp dosimetryofheavyionexposuretohumancellsusingnanoscopicimagingofdoublestrandbreakrepairproteinclusters AT girsts dosimetryofheavyionexposuretohumancellsusingnanoscopicimagingofdoublestrandbreakrepairproteinclusters AT sammerm dosimetryofheavyionexposuretohumancellsusingnanoscopicimagingofdoublestrandbreakrepairproteinclusters AT schwarzb dosimetryofheavyionexposuretohumancellsusingnanoscopicimagingofdoublestrandbreakrepairproteinclusters AT dollingerg dosimetryofheavyionexposuretohumancellsusingnanoscopicimagingofdoublestrandbreakrepairproteinclusters |