Cargando…

Minimalizing Non-point Source Pollution Using a Cooperative Ion-Selective Electrode System for Estimating Nitrate Nitrogen in Soil

Nitrate nitrogen ([Formula: see text] -N) in the soil is one of the important nutrients for growing crops. During the period of precipitation or irrigation, an excessive [Formula: see text] -N readily causes its leaching or runoff from the soil surface to rivers due to inaccurate fertilization and w...

Descripción completa

Detalles Bibliográficos
Autores principales: Su, Rui, Wu, Junfeng, Hu, Jiandong, Ma, Liuzheng, Ahmed, Shakeel, Zhang, Yanyan, Abdulraheem, Mukhtar Iderawumi, Birech, Zephania, Li, Linze, Li, Can, Wei, Wentao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8790048/
https://www.ncbi.nlm.nih.gov/pubmed/35095982
http://dx.doi.org/10.3389/fpls.2021.810214
Descripción
Sumario:Nitrate nitrogen ([Formula: see text] -N) in the soil is one of the important nutrients for growing crops. During the period of precipitation or irrigation, an excessive [Formula: see text] -N readily causes its leaching or runoff from the soil surface to rivers due to inaccurate fertilization and water management, leading to non-point source pollution. In general, the measurement of the [Formula: see text]-N relies upon the laboratory-based absorbance, which is often time-consuming, therefore not suitable for the rapid measurements in the field directly. Ion-selective electrodes (ISEs) support the possibility of [Formula: see text]-N measurement by measuring the nitrate ([Formula: see text]) ions in soil quickly and accurately due to the high water solubility and mobility of [Formula: see text] ions. However, such a method suffers from a complicated calibration to remove the influences caused by both temperature and other ions in the measured solution, thus limiting field use. In this study, a kind of all-solid ISE system combined with a temperature sensor and a pH electrode is proposed to automatically measure the concentrations of the [Formula: see text]-N. In this study, a soil water content calibration function was established, which significantly reduces a relative error (RE) by 13.09%. The experimental results showed that the stabilization time of this electrode system was less than 15 s with a slope of −51.63 mV/decade in the linear range of 10(–5)–10(–2.2) mol/L. Both the limit of detection of 0.5 ppm of the [Formula: see text]-N and a relative SD of less than 3% were obtained together with the recovery rate of 90–110%. Compared with the UV-Vis spectroscopy method, a correlation coefficient (R(2)) of 0.9952 was obtained. The performances of this all-solid ISE system are satisfied for measuring the [Formula: see text]-N in the field.