Cargando…
Effect of data binning and frame averaging for micro-CT image acquisition on the morphometric outcome of bone repair assessment
Despite the current advances in micro-CT analysis, the influence of some image acquisition parameters on the morphometric assessment outcome have not been fully elucidated. The aim of this study was to determine whether data binning and frame averaging affect the morphometric outcome of bone repair...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8791988/ https://www.ncbi.nlm.nih.gov/pubmed/35082347 http://dx.doi.org/10.1038/s41598-022-05459-6 |
_version_ | 1784640307862700032 |
---|---|
author | Irie, Milena Suemi Spin-Neto, Rubens Borges, Juliana Simeão Wenzel, Ann Soares, Priscilla Barbosa Ferreira |
author_facet | Irie, Milena Suemi Spin-Neto, Rubens Borges, Juliana Simeão Wenzel, Ann Soares, Priscilla Barbosa Ferreira |
author_sort | Irie, Milena Suemi |
collection | PubMed |
description | Despite the current advances in micro-CT analysis, the influence of some image acquisition parameters on the morphometric assessment outcome have not been fully elucidated. The aim of this study was to determine whether data binning and frame averaging affect the morphometric outcome of bone repair assessment using micro-CT. Four Wistar rats’ tibiae with a surgically created bone defect were imaged with micro-CT six times each, frame averaging set to 1 and 2, and data binning set to 1, 2 and 4, for each of the averaging values. Two-way ANOVA followed by Bonferroni tests assessed the significance of frame averaging and data binning on a set of morphometric parameters assessed in the image volumes (p < 0.01). The effect of frame averaging was not significant for any of the assessed parameters. Increased data binning led to larger trabecular thickness. In contrast, smaller bone volume fraction and bone volume were found as data binning increased. Trabeculae number and trabecular separation were not influenced by any of the parameters. In conclusion, the morphometric outcome of bone repair assessment in micro-CT demonstrated dependency upon data binning, but not frame averaging. Therefore, image acquisition of small anatomical structures (e.g., rat trabeculae) should be performed without data binning. |
format | Online Article Text |
id | pubmed-8791988 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-87919882022-01-27 Effect of data binning and frame averaging for micro-CT image acquisition on the morphometric outcome of bone repair assessment Irie, Milena Suemi Spin-Neto, Rubens Borges, Juliana Simeão Wenzel, Ann Soares, Priscilla Barbosa Ferreira Sci Rep Article Despite the current advances in micro-CT analysis, the influence of some image acquisition parameters on the morphometric assessment outcome have not been fully elucidated. The aim of this study was to determine whether data binning and frame averaging affect the morphometric outcome of bone repair assessment using micro-CT. Four Wistar rats’ tibiae with a surgically created bone defect were imaged with micro-CT six times each, frame averaging set to 1 and 2, and data binning set to 1, 2 and 4, for each of the averaging values. Two-way ANOVA followed by Bonferroni tests assessed the significance of frame averaging and data binning on a set of morphometric parameters assessed in the image volumes (p < 0.01). The effect of frame averaging was not significant for any of the assessed parameters. Increased data binning led to larger trabecular thickness. In contrast, smaller bone volume fraction and bone volume were found as data binning increased. Trabeculae number and trabecular separation were not influenced by any of the parameters. In conclusion, the morphometric outcome of bone repair assessment in micro-CT demonstrated dependency upon data binning, but not frame averaging. Therefore, image acquisition of small anatomical structures (e.g., rat trabeculae) should be performed without data binning. Nature Publishing Group UK 2022-01-26 /pmc/articles/PMC8791988/ /pubmed/35082347 http://dx.doi.org/10.1038/s41598-022-05459-6 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Irie, Milena Suemi Spin-Neto, Rubens Borges, Juliana Simeão Wenzel, Ann Soares, Priscilla Barbosa Ferreira Effect of data binning and frame averaging for micro-CT image acquisition on the morphometric outcome of bone repair assessment |
title | Effect of data binning and frame averaging for micro-CT image acquisition on the morphometric outcome of bone repair assessment |
title_full | Effect of data binning and frame averaging for micro-CT image acquisition on the morphometric outcome of bone repair assessment |
title_fullStr | Effect of data binning and frame averaging for micro-CT image acquisition on the morphometric outcome of bone repair assessment |
title_full_unstemmed | Effect of data binning and frame averaging for micro-CT image acquisition on the morphometric outcome of bone repair assessment |
title_short | Effect of data binning and frame averaging for micro-CT image acquisition on the morphometric outcome of bone repair assessment |
title_sort | effect of data binning and frame averaging for micro-ct image acquisition on the morphometric outcome of bone repair assessment |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8791988/ https://www.ncbi.nlm.nih.gov/pubmed/35082347 http://dx.doi.org/10.1038/s41598-022-05459-6 |
work_keys_str_mv | AT iriemilenasuemi effectofdatabinningandframeaveragingformicroctimageacquisitiononthemorphometricoutcomeofbonerepairassessment AT spinnetorubens effectofdatabinningandframeaveragingformicroctimageacquisitiononthemorphometricoutcomeofbonerepairassessment AT borgesjulianasimeao effectofdatabinningandframeaveragingformicroctimageacquisitiononthemorphometricoutcomeofbonerepairassessment AT wenzelann effectofdatabinningandframeaveragingformicroctimageacquisitiononthemorphometricoutcomeofbonerepairassessment AT soarespriscillabarbosaferreira effectofdatabinningandframeaveragingformicroctimageacquisitiononthemorphometricoutcomeofbonerepairassessment |