Cargando…

Evaluation of the Sentinel-FOB gold faecal immunochemical test for the presence of haemoglobin using the automated Roche Cobas 8000 system()

OBJECTIVES: Faecal immunochemical tests (FIT) for the detection of haemoglobin are widely used in the diagnostic pathway of colorectal cancer (CRC) in patients presenting with lower abdominal symptoms. Several quantitative immunochemical tests are available, however only a few tests are available on...

Descripción completa

Detalles Bibliográficos
Autores principales: Schwettmann, Lutz, Lied, Astrid, Eriksen, Ragnar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8792414/
https://www.ncbi.nlm.nih.gov/pubmed/35198716
http://dx.doi.org/10.1016/j.plabm.2022.e00263
_version_ 1784640357593513984
author Schwettmann, Lutz
Lied, Astrid
Eriksen, Ragnar
author_facet Schwettmann, Lutz
Lied, Astrid
Eriksen, Ragnar
author_sort Schwettmann, Lutz
collection PubMed
description OBJECTIVES: Faecal immunochemical tests (FIT) for the detection of haemoglobin are widely used in the diagnostic pathway of colorectal cancer (CRC) in patients presenting with lower abdominal symptoms. Several quantitative immunochemical tests are available, however only a few tests are available on high throughput automated analyzers. Here we report the analytical and clinical evaluation of the Sentinel-FOB Gold assay on the Roche Cobas 8000 automated system. DESIGN: and Methods: The assessment of the analytical performance of the assay on the Roche Cobas analyzer comprised determination of imprecision, accuracy, limit of detection, linearity, carryover and prozone effect. In the clinical evaluation part of the study 163 patients presenting for coloscopy with lower abdominal symptoms were included in the study. Diagnostic accuracy and optimal cutoff of the FIT-assay were determined by comparing faecal haemoglobin (f-Hb) concentrations with coloscopy findings as reference. RESULTS: We confirmed good analytical performance of the assay on the Roche Cobas system. Patients with CRC had significant higher f-Hb concentrations than patients with non-advanced adenomas and patients with normal findings by coloscopy. When applying a cutoff of 10 μg/g the sensitivity and specificity were 96.2% and 51.8%, respectively for CRC and 84.6% and 57.7% for CRC and advanced adenoma. CONCLUSION: The Sentinel-FOB Gold assay is appropriate for application on the automated Roche Cobas 8000 analyzer. The assay shows good analytical performance on the system. With regard to early detection of significant colorectal diseases a cutoff of 10 μg/g seems to be optimal.
format Online
Article
Text
id pubmed-8792414
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-87924142022-02-22 Evaluation of the Sentinel-FOB gold faecal immunochemical test for the presence of haemoglobin using the automated Roche Cobas 8000 system() Schwettmann, Lutz Lied, Astrid Eriksen, Ragnar Pract Lab Med Article OBJECTIVES: Faecal immunochemical tests (FIT) for the detection of haemoglobin are widely used in the diagnostic pathway of colorectal cancer (CRC) in patients presenting with lower abdominal symptoms. Several quantitative immunochemical tests are available, however only a few tests are available on high throughput automated analyzers. Here we report the analytical and clinical evaluation of the Sentinel-FOB Gold assay on the Roche Cobas 8000 automated system. DESIGN: and Methods: The assessment of the analytical performance of the assay on the Roche Cobas analyzer comprised determination of imprecision, accuracy, limit of detection, linearity, carryover and prozone effect. In the clinical evaluation part of the study 163 patients presenting for coloscopy with lower abdominal symptoms were included in the study. Diagnostic accuracy and optimal cutoff of the FIT-assay were determined by comparing faecal haemoglobin (f-Hb) concentrations with coloscopy findings as reference. RESULTS: We confirmed good analytical performance of the assay on the Roche Cobas system. Patients with CRC had significant higher f-Hb concentrations than patients with non-advanced adenomas and patients with normal findings by coloscopy. When applying a cutoff of 10 μg/g the sensitivity and specificity were 96.2% and 51.8%, respectively for CRC and 84.6% and 57.7% for CRC and advanced adenoma. CONCLUSION: The Sentinel-FOB Gold assay is appropriate for application on the automated Roche Cobas 8000 analyzer. The assay shows good analytical performance on the system. With regard to early detection of significant colorectal diseases a cutoff of 10 μg/g seems to be optimal. Elsevier 2022-01-15 /pmc/articles/PMC8792414/ /pubmed/35198716 http://dx.doi.org/10.1016/j.plabm.2022.e00263 Text en © 2022 The Authors. Published by Elsevier B.V. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Schwettmann, Lutz
Lied, Astrid
Eriksen, Ragnar
Evaluation of the Sentinel-FOB gold faecal immunochemical test for the presence of haemoglobin using the automated Roche Cobas 8000 system()
title Evaluation of the Sentinel-FOB gold faecal immunochemical test for the presence of haemoglobin using the automated Roche Cobas 8000 system()
title_full Evaluation of the Sentinel-FOB gold faecal immunochemical test for the presence of haemoglobin using the automated Roche Cobas 8000 system()
title_fullStr Evaluation of the Sentinel-FOB gold faecal immunochemical test for the presence of haemoglobin using the automated Roche Cobas 8000 system()
title_full_unstemmed Evaluation of the Sentinel-FOB gold faecal immunochemical test for the presence of haemoglobin using the automated Roche Cobas 8000 system()
title_short Evaluation of the Sentinel-FOB gold faecal immunochemical test for the presence of haemoglobin using the automated Roche Cobas 8000 system()
title_sort evaluation of the sentinel-fob gold faecal immunochemical test for the presence of haemoglobin using the automated roche cobas 8000 system()
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8792414/
https://www.ncbi.nlm.nih.gov/pubmed/35198716
http://dx.doi.org/10.1016/j.plabm.2022.e00263
work_keys_str_mv AT schwettmannlutz evaluationofthesentinelfobgoldfaecalimmunochemicaltestforthepresenceofhaemoglobinusingtheautomatedrochecobas8000system
AT liedastrid evaluationofthesentinelfobgoldfaecalimmunochemicaltestforthepresenceofhaemoglobinusingtheautomatedrochecobas8000system
AT eriksenragnar evaluationofthesentinelfobgoldfaecalimmunochemicaltestforthepresenceofhaemoglobinusingtheautomatedrochecobas8000system