Cargando…

Volume Measurements on Weightbearing Computed Tomography Can Detect Subtle Syndesmotic Instability

CATEGORY: Ankle; Trauma INTRODUCTION/PURPOSE: The ability to compare the ankle joints bilaterally in a 3D manner under physiologic weight provided by weight-bearing CT has led to a more accurate diagnostic method. While weight-bearing computed tomography (WBCT) allows 3D visualization of the distal...

Descripción completa

Detalles Bibliográficos
Autores principales: Ashkani-Esfahani, Soheil, Bhimani, Rohan, Lubberts, Bart, Kerkhoffs, Gino, Waryasz, Gregory R., DiGiovanni, Christopher W., Guss, Daniel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8792654/
http://dx.doi.org/10.1177/2473011421S00093
_version_ 1784640421426626560
author Ashkani-Esfahani, Soheil
Bhimani, Rohan
Lubberts, Bart
Kerkhoffs, Gino
Waryasz, Gregory R.
DiGiovanni, Christopher W.
Guss, Daniel
author_facet Ashkani-Esfahani, Soheil
Bhimani, Rohan
Lubberts, Bart
Kerkhoffs, Gino
Waryasz, Gregory R.
DiGiovanni, Christopher W.
Guss, Daniel
author_sort Ashkani-Esfahani, Soheil
collection PubMed
description CATEGORY: Ankle; Trauma INTRODUCTION/PURPOSE: The ability to compare the ankle joints bilaterally in a 3D manner under physiologic weight provided by weight-bearing CT has led to a more accurate diagnostic method. While weight-bearing computed tomography (WBCT) allows 3D visualization of the distal syndesmosis, image interpretation has largely relied on 1D distance and, more recently, 2D area measurements. This study aimed to: 1) determine the sensitivity and specificity of 2D area and 3D volume WBCT measurements towards detecting subtle syndesmotic instability, 2) evaluate whether the patterns of changes in the 3D shape of the syndesmosis can be attributed to the type of ligament injury. METHODS: A total of 24 patients with unilateral subtle syndesmotic instability and 24 individuals with uninjured ankles (controls) with bilateral ankle WBCT were assessed retrospectively. First, 2D areas at 0, 1, 3, 5,10 cm, and 3D volumes at 1, 3, 5, and 10cm above the tibial plafond were measured bilaterally. Secondly, given the volume measurement at the level of 5 cm proximal to the platform as the most sensitive and specific method introduced in this study, the 3D model of the distal tibiofibular space was created based on WBCT in a subset of 8 patients out of 24 in whom the type of ligament injury was recognized via MRI. The 3D model of the injured side was superimposed on the uninjured contralateral side to visualize the pattern of changes in different planes. P<0.05 was considered statistically significant. RESULTS: No specific pattern was observed in 2D and 3D models of the syndesmotic space which can be attributed to a specific ligamentous tear. However, in patients with IOL rupture, the volume increased by >=39% at 5 cm height while without IOL injury the volume increased up to 26% (figure 1). The percentage of changes in 2D areas and 3D volumes showed significant differences in areas at 0cm (19.2%; p=0.004), 1cm (24.1%; p=0.002), 3cm (27.3%; p=0.003), 5cm (28%; p=0.002), and 10cm (29.3%; p=0.003) as well as volumes at 1cm (31.2%; p=0.003), 3cm (26.5%; p=0.001), 5cm (25.4%; p<0.001), and 10cm (24.7%; p=0.004) proximal to tibial plafond. Volume up to 5cm showed the lowest p-value, higher sensitivity (95.8%, 95%CI:87.8-100), and specificity (83.3%, 95% CI:68.4-98.2) for detection of syndesmotic instability. CONCLUSION: We suggest 3D volume measurements, best measured up to 5cm proximal to the plafond, as a promising means of diagnosing syndesmotic instability, particularly for subtle cases that are hard to detect.
format Online
Article
Text
id pubmed-8792654
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-87926542022-01-28 Volume Measurements on Weightbearing Computed Tomography Can Detect Subtle Syndesmotic Instability Ashkani-Esfahani, Soheil Bhimani, Rohan Lubberts, Bart Kerkhoffs, Gino Waryasz, Gregory R. DiGiovanni, Christopher W. Guss, Daniel Foot Ankle Orthop Article CATEGORY: Ankle; Trauma INTRODUCTION/PURPOSE: The ability to compare the ankle joints bilaterally in a 3D manner under physiologic weight provided by weight-bearing CT has led to a more accurate diagnostic method. While weight-bearing computed tomography (WBCT) allows 3D visualization of the distal syndesmosis, image interpretation has largely relied on 1D distance and, more recently, 2D area measurements. This study aimed to: 1) determine the sensitivity and specificity of 2D area and 3D volume WBCT measurements towards detecting subtle syndesmotic instability, 2) evaluate whether the patterns of changes in the 3D shape of the syndesmosis can be attributed to the type of ligament injury. METHODS: A total of 24 patients with unilateral subtle syndesmotic instability and 24 individuals with uninjured ankles (controls) with bilateral ankle WBCT were assessed retrospectively. First, 2D areas at 0, 1, 3, 5,10 cm, and 3D volumes at 1, 3, 5, and 10cm above the tibial plafond were measured bilaterally. Secondly, given the volume measurement at the level of 5 cm proximal to the platform as the most sensitive and specific method introduced in this study, the 3D model of the distal tibiofibular space was created based on WBCT in a subset of 8 patients out of 24 in whom the type of ligament injury was recognized via MRI. The 3D model of the injured side was superimposed on the uninjured contralateral side to visualize the pattern of changes in different planes. P<0.05 was considered statistically significant. RESULTS: No specific pattern was observed in 2D and 3D models of the syndesmotic space which can be attributed to a specific ligamentous tear. However, in patients with IOL rupture, the volume increased by >=39% at 5 cm height while without IOL injury the volume increased up to 26% (figure 1). The percentage of changes in 2D areas and 3D volumes showed significant differences in areas at 0cm (19.2%; p=0.004), 1cm (24.1%; p=0.002), 3cm (27.3%; p=0.003), 5cm (28%; p=0.002), and 10cm (29.3%; p=0.003) as well as volumes at 1cm (31.2%; p=0.003), 3cm (26.5%; p=0.001), 5cm (25.4%; p<0.001), and 10cm (24.7%; p=0.004) proximal to tibial plafond. Volume up to 5cm showed the lowest p-value, higher sensitivity (95.8%, 95%CI:87.8-100), and specificity (83.3%, 95% CI:68.4-98.2) for detection of syndesmotic instability. CONCLUSION: We suggest 3D volume measurements, best measured up to 5cm proximal to the plafond, as a promising means of diagnosing syndesmotic instability, particularly for subtle cases that are hard to detect. SAGE Publications 2022-01-20 /pmc/articles/PMC8792654/ http://dx.doi.org/10.1177/2473011421S00093 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Article
Ashkani-Esfahani, Soheil
Bhimani, Rohan
Lubberts, Bart
Kerkhoffs, Gino
Waryasz, Gregory R.
DiGiovanni, Christopher W.
Guss, Daniel
Volume Measurements on Weightbearing Computed Tomography Can Detect Subtle Syndesmotic Instability
title Volume Measurements on Weightbearing Computed Tomography Can Detect Subtle Syndesmotic Instability
title_full Volume Measurements on Weightbearing Computed Tomography Can Detect Subtle Syndesmotic Instability
title_fullStr Volume Measurements on Weightbearing Computed Tomography Can Detect Subtle Syndesmotic Instability
title_full_unstemmed Volume Measurements on Weightbearing Computed Tomography Can Detect Subtle Syndesmotic Instability
title_short Volume Measurements on Weightbearing Computed Tomography Can Detect Subtle Syndesmotic Instability
title_sort volume measurements on weightbearing computed tomography can detect subtle syndesmotic instability
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8792654/
http://dx.doi.org/10.1177/2473011421S00093
work_keys_str_mv AT ashkaniesfahanisoheil volumemeasurementsonweightbearingcomputedtomographycandetectsubtlesyndesmoticinstability
AT bhimanirohan volumemeasurementsonweightbearingcomputedtomographycandetectsubtlesyndesmoticinstability
AT lubbertsbart volumemeasurementsonweightbearingcomputedtomographycandetectsubtlesyndesmoticinstability
AT kerkhoffsgino volumemeasurementsonweightbearingcomputedtomographycandetectsubtlesyndesmoticinstability
AT waryaszgregoryr volumemeasurementsonweightbearingcomputedtomographycandetectsubtlesyndesmoticinstability
AT digiovannichristopherw volumemeasurementsonweightbearingcomputedtomographycandetectsubtlesyndesmoticinstability
AT gussdaniel volumemeasurementsonweightbearingcomputedtomographycandetectsubtlesyndesmoticinstability