Cargando…
Handheld Echocardiography in a Clinical Practice Scenario: Concordances Compared to Standard Echocardiographic Reports
BACKGROUND: The purpose of this study was to assess the utility of a handheld device (HH) used during common daily practice and its agreement with the results of a standard echocardiography study (STD) performed by experienced sonographers and echocardiographer. METHODS: A prospective follow-up was...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Echocardiography
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8792719/ https://www.ncbi.nlm.nih.gov/pubmed/35086166 http://dx.doi.org/10.4250/jcvi.2020.0241 |
_version_ | 1784640437789655040 |
---|---|
author | Blume, Gustavo Gavazzoni Lechinewski, Luka David Vieira, Isabela Pedroza Clausell, Nadine Bertinato, Giovana Paludo Machado-Júnior, Paulo André Bispo Berro, Pedro Goulart Moura, Lidia Ana Zytynski Tsang, Teresa |
author_facet | Blume, Gustavo Gavazzoni Lechinewski, Luka David Vieira, Isabela Pedroza Clausell, Nadine Bertinato, Giovana Paludo Machado-Júnior, Paulo André Bispo Berro, Pedro Goulart Moura, Lidia Ana Zytynski Tsang, Teresa |
author_sort | Blume, Gustavo Gavazzoni |
collection | PubMed |
description | BACKGROUND: The purpose of this study was to assess the utility of a handheld device (HH) used during common daily practice and its agreement with the results of a standard echocardiography study (STD) performed by experienced sonographers and echocardiographer. METHODS: A prospective follow-up was conducted in an adult outpatient echocardiography clinic. Experienced sonographers performed the STD and an experienced echocardiographer performed the HH. STD included 2-dimensional images, Doppler and hemodynamics analysis. Hemodynamic assessment was not performed with the HH device because the HH does not include such technology. The images were interpreted by blinded echocardiographers, and the agreement between the reports was analyzed. RESULTS: A total of 108 patients were included; and the concordance for left ventricle (LV) ejection fraction (EF), wall motion score index, LV and right ventricle (RV) function, RV size, and mitral and aortic stenosis was excellent with κ values greater than 0.80. Wall motion abnormalities had good concordance (κ value 0.78). The agreement for LV hypertrophy, mitral and aortic regurgitation was moderate, and tricuspid and pulmonary regurgitation agreements were low (κ values of 0.26 and 0.25, respectively). CONCLUSIONS: In a daily practice scenario with experienced hands, HH demonstrated good correlation for most echocardiography indications, such as ventricular size and function assessment and stenosis valve lesion analyses. |
format | Online Article Text |
id | pubmed-8792719 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Korean Society of Echocardiography |
record_format | MEDLINE/PubMed |
spelling | pubmed-87927192022-02-02 Handheld Echocardiography in a Clinical Practice Scenario: Concordances Compared to Standard Echocardiographic Reports Blume, Gustavo Gavazzoni Lechinewski, Luka David Vieira, Isabela Pedroza Clausell, Nadine Bertinato, Giovana Paludo Machado-Júnior, Paulo André Bispo Berro, Pedro Goulart Moura, Lidia Ana Zytynski Tsang, Teresa J Cardiovasc Imaging Original Article BACKGROUND: The purpose of this study was to assess the utility of a handheld device (HH) used during common daily practice and its agreement with the results of a standard echocardiography study (STD) performed by experienced sonographers and echocardiographer. METHODS: A prospective follow-up was conducted in an adult outpatient echocardiography clinic. Experienced sonographers performed the STD and an experienced echocardiographer performed the HH. STD included 2-dimensional images, Doppler and hemodynamics analysis. Hemodynamic assessment was not performed with the HH device because the HH does not include such technology. The images were interpreted by blinded echocardiographers, and the agreement between the reports was analyzed. RESULTS: A total of 108 patients were included; and the concordance for left ventricle (LV) ejection fraction (EF), wall motion score index, LV and right ventricle (RV) function, RV size, and mitral and aortic stenosis was excellent with κ values greater than 0.80. Wall motion abnormalities had good concordance (κ value 0.78). The agreement for LV hypertrophy, mitral and aortic regurgitation was moderate, and tricuspid and pulmonary regurgitation agreements were low (κ values of 0.26 and 0.25, respectively). CONCLUSIONS: In a daily practice scenario with experienced hands, HH demonstrated good correlation for most echocardiography indications, such as ventricular size and function assessment and stenosis valve lesion analyses. Korean Society of Echocardiography 2022-01 2021-05-28 /pmc/articles/PMC8792719/ /pubmed/35086166 http://dx.doi.org/10.4250/jcvi.2020.0241 Text en Copyright © 2022 Korean Society of Echocardiography https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Blume, Gustavo Gavazzoni Lechinewski, Luka David Vieira, Isabela Pedroza Clausell, Nadine Bertinato, Giovana Paludo Machado-Júnior, Paulo André Bispo Berro, Pedro Goulart Moura, Lidia Ana Zytynski Tsang, Teresa Handheld Echocardiography in a Clinical Practice Scenario: Concordances Compared to Standard Echocardiographic Reports |
title | Handheld Echocardiography in a Clinical Practice Scenario: Concordances Compared to Standard Echocardiographic Reports |
title_full | Handheld Echocardiography in a Clinical Practice Scenario: Concordances Compared to Standard Echocardiographic Reports |
title_fullStr | Handheld Echocardiography in a Clinical Practice Scenario: Concordances Compared to Standard Echocardiographic Reports |
title_full_unstemmed | Handheld Echocardiography in a Clinical Practice Scenario: Concordances Compared to Standard Echocardiographic Reports |
title_short | Handheld Echocardiography in a Clinical Practice Scenario: Concordances Compared to Standard Echocardiographic Reports |
title_sort | handheld echocardiography in a clinical practice scenario: concordances compared to standard echocardiographic reports |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8792719/ https://www.ncbi.nlm.nih.gov/pubmed/35086166 http://dx.doi.org/10.4250/jcvi.2020.0241 |
work_keys_str_mv | AT blumegustavogavazzoni handheldechocardiographyinaclinicalpracticescenarioconcordancescomparedtostandardechocardiographicreports AT lechinewskilukadavid handheldechocardiographyinaclinicalpracticescenarioconcordancescomparedtostandardechocardiographicreports AT vieiraisabelapedroza handheldechocardiographyinaclinicalpracticescenarioconcordancescomparedtostandardechocardiographicreports AT clausellnadine handheldechocardiographyinaclinicalpracticescenarioconcordancescomparedtostandardechocardiographicreports AT bertinatogiovanapaludo handheldechocardiographyinaclinicalpracticescenarioconcordancescomparedtostandardechocardiographicreports AT machadojuniorpauloandrebispo handheldechocardiographyinaclinicalpracticescenarioconcordancescomparedtostandardechocardiographicreports AT berropedrogoulart handheldechocardiographyinaclinicalpracticescenarioconcordancescomparedtostandardechocardiographicreports AT mouralidiaanazytynski handheldechocardiographyinaclinicalpracticescenarioconcordancescomparedtostandardechocardiographicreports AT tsangteresa handheldechocardiographyinaclinicalpracticescenarioconcordancescomparedtostandardechocardiographicreports |