Cargando…

Handheld Echocardiography in a Clinical Practice Scenario: Concordances Compared to Standard Echocardiographic Reports

BACKGROUND: The purpose of this study was to assess the utility of a handheld device (HH) used during common daily practice and its agreement with the results of a standard echocardiography study (STD) performed by experienced sonographers and echocardiographer. METHODS: A prospective follow-up was...

Descripción completa

Detalles Bibliográficos
Autores principales: Blume, Gustavo Gavazzoni, Lechinewski, Luka David, Vieira, Isabela Pedroza, Clausell, Nadine, Bertinato, Giovana Paludo, Machado-Júnior, Paulo André Bispo, Berro, Pedro Goulart, Moura, Lidia Ana Zytynski, Tsang, Teresa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Echocardiography 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8792719/
https://www.ncbi.nlm.nih.gov/pubmed/35086166
http://dx.doi.org/10.4250/jcvi.2020.0241
_version_ 1784640437789655040
author Blume, Gustavo Gavazzoni
Lechinewski, Luka David
Vieira, Isabela Pedroza
Clausell, Nadine
Bertinato, Giovana Paludo
Machado-Júnior, Paulo André Bispo
Berro, Pedro Goulart
Moura, Lidia Ana Zytynski
Tsang, Teresa
author_facet Blume, Gustavo Gavazzoni
Lechinewski, Luka David
Vieira, Isabela Pedroza
Clausell, Nadine
Bertinato, Giovana Paludo
Machado-Júnior, Paulo André Bispo
Berro, Pedro Goulart
Moura, Lidia Ana Zytynski
Tsang, Teresa
author_sort Blume, Gustavo Gavazzoni
collection PubMed
description BACKGROUND: The purpose of this study was to assess the utility of a handheld device (HH) used during common daily practice and its agreement with the results of a standard echocardiography study (STD) performed by experienced sonographers and echocardiographer. METHODS: A prospective follow-up was conducted in an adult outpatient echocardiography clinic. Experienced sonographers performed the STD and an experienced echocardiographer performed the HH. STD included 2-dimensional images, Doppler and hemodynamics analysis. Hemodynamic assessment was not performed with the HH device because the HH does not include such technology. The images were interpreted by blinded echocardiographers, and the agreement between the reports was analyzed. RESULTS: A total of 108 patients were included; and the concordance for left ventricle (LV) ejection fraction (EF), wall motion score index, LV and right ventricle (RV) function, RV size, and mitral and aortic stenosis was excellent with κ values greater than 0.80. Wall motion abnormalities had good concordance (κ value 0.78). The agreement for LV hypertrophy, mitral and aortic regurgitation was moderate, and tricuspid and pulmonary regurgitation agreements were low (κ values of 0.26 and 0.25, respectively). CONCLUSIONS: In a daily practice scenario with experienced hands, HH demonstrated good correlation for most echocardiography indications, such as ventricular size and function assessment and stenosis valve lesion analyses.
format Online
Article
Text
id pubmed-8792719
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Korean Society of Echocardiography
record_format MEDLINE/PubMed
spelling pubmed-87927192022-02-02 Handheld Echocardiography in a Clinical Practice Scenario: Concordances Compared to Standard Echocardiographic Reports Blume, Gustavo Gavazzoni Lechinewski, Luka David Vieira, Isabela Pedroza Clausell, Nadine Bertinato, Giovana Paludo Machado-Júnior, Paulo André Bispo Berro, Pedro Goulart Moura, Lidia Ana Zytynski Tsang, Teresa J Cardiovasc Imaging Original Article BACKGROUND: The purpose of this study was to assess the utility of a handheld device (HH) used during common daily practice and its agreement with the results of a standard echocardiography study (STD) performed by experienced sonographers and echocardiographer. METHODS: A prospective follow-up was conducted in an adult outpatient echocardiography clinic. Experienced sonographers performed the STD and an experienced echocardiographer performed the HH. STD included 2-dimensional images, Doppler and hemodynamics analysis. Hemodynamic assessment was not performed with the HH device because the HH does not include such technology. The images were interpreted by blinded echocardiographers, and the agreement between the reports was analyzed. RESULTS: A total of 108 patients were included; and the concordance for left ventricle (LV) ejection fraction (EF), wall motion score index, LV and right ventricle (RV) function, RV size, and mitral and aortic stenosis was excellent with κ values greater than 0.80. Wall motion abnormalities had good concordance (κ value 0.78). The agreement for LV hypertrophy, mitral and aortic regurgitation was moderate, and tricuspid and pulmonary regurgitation agreements were low (κ values of 0.26 and 0.25, respectively). CONCLUSIONS: In a daily practice scenario with experienced hands, HH demonstrated good correlation for most echocardiography indications, such as ventricular size and function assessment and stenosis valve lesion analyses. Korean Society of Echocardiography 2022-01 2021-05-28 /pmc/articles/PMC8792719/ /pubmed/35086166 http://dx.doi.org/10.4250/jcvi.2020.0241 Text en Copyright © 2022 Korean Society of Echocardiography https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Blume, Gustavo Gavazzoni
Lechinewski, Luka David
Vieira, Isabela Pedroza
Clausell, Nadine
Bertinato, Giovana Paludo
Machado-Júnior, Paulo André Bispo
Berro, Pedro Goulart
Moura, Lidia Ana Zytynski
Tsang, Teresa
Handheld Echocardiography in a Clinical Practice Scenario: Concordances Compared to Standard Echocardiographic Reports
title Handheld Echocardiography in a Clinical Practice Scenario: Concordances Compared to Standard Echocardiographic Reports
title_full Handheld Echocardiography in a Clinical Practice Scenario: Concordances Compared to Standard Echocardiographic Reports
title_fullStr Handheld Echocardiography in a Clinical Practice Scenario: Concordances Compared to Standard Echocardiographic Reports
title_full_unstemmed Handheld Echocardiography in a Clinical Practice Scenario: Concordances Compared to Standard Echocardiographic Reports
title_short Handheld Echocardiography in a Clinical Practice Scenario: Concordances Compared to Standard Echocardiographic Reports
title_sort handheld echocardiography in a clinical practice scenario: concordances compared to standard echocardiographic reports
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8792719/
https://www.ncbi.nlm.nih.gov/pubmed/35086166
http://dx.doi.org/10.4250/jcvi.2020.0241
work_keys_str_mv AT blumegustavogavazzoni handheldechocardiographyinaclinicalpracticescenarioconcordancescomparedtostandardechocardiographicreports
AT lechinewskilukadavid handheldechocardiographyinaclinicalpracticescenarioconcordancescomparedtostandardechocardiographicreports
AT vieiraisabelapedroza handheldechocardiographyinaclinicalpracticescenarioconcordancescomparedtostandardechocardiographicreports
AT clausellnadine handheldechocardiographyinaclinicalpracticescenarioconcordancescomparedtostandardechocardiographicreports
AT bertinatogiovanapaludo handheldechocardiographyinaclinicalpracticescenarioconcordancescomparedtostandardechocardiographicreports
AT machadojuniorpauloandrebispo handheldechocardiographyinaclinicalpracticescenarioconcordancescomparedtostandardechocardiographicreports
AT berropedrogoulart handheldechocardiographyinaclinicalpracticescenarioconcordancescomparedtostandardechocardiographicreports
AT mouralidiaanazytynski handheldechocardiographyinaclinicalpracticescenarioconcordancescomparedtostandardechocardiographicreports
AT tsangteresa handheldechocardiographyinaclinicalpracticescenarioconcordancescomparedtostandardechocardiographicreports