Cargando…
Low-Cost Clamp-On Photometers (ClampOD) and Tube Photometers (TubeOD) for Online Cell Density Determination
Optical density (OD) measurement is the gold standard to estimate microbial cell density in aqueous systems. Recording microbial growth curves is essential to assess substrate utilization, gauge sensitivity to inhibitors or toxins, or determine the perfect sampling point. Manual sampling for cuvette...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8793360/ https://www.ncbi.nlm.nih.gov/pubmed/35095803 http://dx.doi.org/10.3389/fmicb.2021.790576 |
_version_ | 1784640581544181760 |
---|---|
author | Deutzmann, Jörg S. Callander, Grace Gu, Wenyu Müller, Albert L. McCully, Alexandra L. Ahn, Jenna Kim Kracke, Frauke Spormann, Alfred M. |
author_facet | Deutzmann, Jörg S. Callander, Grace Gu, Wenyu Müller, Albert L. McCully, Alexandra L. Ahn, Jenna Kim Kracke, Frauke Spormann, Alfred M. |
author_sort | Deutzmann, Jörg S. |
collection | PubMed |
description | Optical density (OD) measurement is the gold standard to estimate microbial cell density in aqueous systems. Recording microbial growth curves is essential to assess substrate utilization, gauge sensitivity to inhibitors or toxins, or determine the perfect sampling point. Manual sampling for cuvette-photometer-based measurements can cause disturbances and impact growth, especially for strictly anaerobic or thermophilic microbes. For slow growing microbes, manual sampling can cause data gaps that complicate analysis. Online OD measurement systems provide a solution, but are often expensive and ill-suited for applications such as monitoring microbial growth in custom or larger anaerobic vessels. Furthermore, growth measurements of thermophilic cultures are limited by the heat sensitivity of complex electronics. Here, we present two simple, low-cost, self-assembled photometers—a “TubeOD” for online measurement of anaerobic and thermophilic cultures in Hungate tubes and a “ClampOD” that can be attached to virtually any transparent growth vessel. Both OD-meters can be calibrated in minutes. We detail the manufacturing and calibration procedure and demonstrate continuous acquisition of high quality cell density data of a variety of microbes, including strict anaerobes, a thermophile, and gas-utilizing strains in various glassware. When calibrated and operated within their detection limits (ca. 0.3–90% of the photosensor voltage range), these self-build OD-meters can be used for continuous measurement of microbial growth in a variety of applications, thereby, simplifying and enhancing everyday lab operations. |
format | Online Article Text |
id | pubmed-8793360 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-87933602022-01-28 Low-Cost Clamp-On Photometers (ClampOD) and Tube Photometers (TubeOD) for Online Cell Density Determination Deutzmann, Jörg S. Callander, Grace Gu, Wenyu Müller, Albert L. McCully, Alexandra L. Ahn, Jenna Kim Kracke, Frauke Spormann, Alfred M. Front Microbiol Microbiology Optical density (OD) measurement is the gold standard to estimate microbial cell density in aqueous systems. Recording microbial growth curves is essential to assess substrate utilization, gauge sensitivity to inhibitors or toxins, or determine the perfect sampling point. Manual sampling for cuvette-photometer-based measurements can cause disturbances and impact growth, especially for strictly anaerobic or thermophilic microbes. For slow growing microbes, manual sampling can cause data gaps that complicate analysis. Online OD measurement systems provide a solution, but are often expensive and ill-suited for applications such as monitoring microbial growth in custom or larger anaerobic vessels. Furthermore, growth measurements of thermophilic cultures are limited by the heat sensitivity of complex electronics. Here, we present two simple, low-cost, self-assembled photometers—a “TubeOD” for online measurement of anaerobic and thermophilic cultures in Hungate tubes and a “ClampOD” that can be attached to virtually any transparent growth vessel. Both OD-meters can be calibrated in minutes. We detail the manufacturing and calibration procedure and demonstrate continuous acquisition of high quality cell density data of a variety of microbes, including strict anaerobes, a thermophile, and gas-utilizing strains in various glassware. When calibrated and operated within their detection limits (ca. 0.3–90% of the photosensor voltage range), these self-build OD-meters can be used for continuous measurement of microbial growth in a variety of applications, thereby, simplifying and enhancing everyday lab operations. Frontiers Media S.A. 2022-01-13 /pmc/articles/PMC8793360/ /pubmed/35095803 http://dx.doi.org/10.3389/fmicb.2021.790576 Text en Copyright © 2022 Deutzmann, Callander, Gu, Müller, McCully, Ahn, Kracke and Spormann. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Microbiology Deutzmann, Jörg S. Callander, Grace Gu, Wenyu Müller, Albert L. McCully, Alexandra L. Ahn, Jenna Kim Kracke, Frauke Spormann, Alfred M. Low-Cost Clamp-On Photometers (ClampOD) and Tube Photometers (TubeOD) for Online Cell Density Determination |
title | Low-Cost Clamp-On Photometers (ClampOD) and Tube Photometers (TubeOD) for Online Cell Density Determination |
title_full | Low-Cost Clamp-On Photometers (ClampOD) and Tube Photometers (TubeOD) for Online Cell Density Determination |
title_fullStr | Low-Cost Clamp-On Photometers (ClampOD) and Tube Photometers (TubeOD) for Online Cell Density Determination |
title_full_unstemmed | Low-Cost Clamp-On Photometers (ClampOD) and Tube Photometers (TubeOD) for Online Cell Density Determination |
title_short | Low-Cost Clamp-On Photometers (ClampOD) and Tube Photometers (TubeOD) for Online Cell Density Determination |
title_sort | low-cost clamp-on photometers (clampod) and tube photometers (tubeod) for online cell density determination |
topic | Microbiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8793360/ https://www.ncbi.nlm.nih.gov/pubmed/35095803 http://dx.doi.org/10.3389/fmicb.2021.790576 |
work_keys_str_mv | AT deutzmannjorgs lowcostclamponphotometersclampodandtubephotometerstubeodforonlinecelldensitydetermination AT callandergrace lowcostclamponphotometersclampodandtubephotometerstubeodforonlinecelldensitydetermination AT guwenyu lowcostclamponphotometersclampodandtubephotometerstubeodforonlinecelldensitydetermination AT mulleralbertl lowcostclamponphotometersclampodandtubephotometerstubeodforonlinecelldensitydetermination AT mccullyalexandral lowcostclamponphotometersclampodandtubephotometerstubeodforonlinecelldensitydetermination AT ahnjennakim lowcostclamponphotometersclampodandtubephotometerstubeodforonlinecelldensitydetermination AT krackefrauke lowcostclamponphotometersclampodandtubephotometerstubeodforonlinecelldensitydetermination AT spormannalfredm lowcostclamponphotometersclampodandtubephotometerstubeodforonlinecelldensitydetermination |