Cargando…

Validating EEG, MEG and Combined MEG and EEG Beamforming for an Estimation of the Epileptogenic Zone in Focal Cortical Dysplasia

MEG and EEG source analysis is frequently used for the presurgical evaluation of pharmacoresistant epilepsy patients. The source localization of the epileptogenic zone depends, among other aspects, on the selected inverse and forward approaches and their respective parameter choices. In this validat...

Descripción completa

Detalles Bibliográficos
Autores principales: Neugebauer, Frank, Antonakakis, Marios, Unnwongse, Kanjana, Parpaley, Yaroslav, Wellmer, Jörg, Rampp, Stefan, Wolters, Carsten H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8796031/
https://www.ncbi.nlm.nih.gov/pubmed/35053857
http://dx.doi.org/10.3390/brainsci12010114
_version_ 1784641213076340736
author Neugebauer, Frank
Antonakakis, Marios
Unnwongse, Kanjana
Parpaley, Yaroslav
Wellmer, Jörg
Rampp, Stefan
Wolters, Carsten H.
author_facet Neugebauer, Frank
Antonakakis, Marios
Unnwongse, Kanjana
Parpaley, Yaroslav
Wellmer, Jörg
Rampp, Stefan
Wolters, Carsten H.
author_sort Neugebauer, Frank
collection PubMed
description MEG and EEG source analysis is frequently used for the presurgical evaluation of pharmacoresistant epilepsy patients. The source localization of the epileptogenic zone depends, among other aspects, on the selected inverse and forward approaches and their respective parameter choices. In this validation study, we compare the standard dipole scanning method with two beamformer approaches for the inverse problem, and we investigate the influence of the covariance estimation method and the strength of regularization on the localization performance for EEG, MEG, and combined EEG and MEG. For forward modelling, we investigate the difference between calibrated six-compartment and standard three-compartment head modelling. In a retrospective study, two patients with focal epilepsy due to focal cortical dysplasia type IIb and seizure freedom following lesionectomy or radiofrequency-guided thermocoagulation (RFTC) used the distance of the localization of interictal epileptic spikes to the resection cavity resp. RFTC lesion as reference for good localization. We found that beamformer localization can be sensitive to the choice of the regularization parameter, which has to be individually optimized. Estimation of the covariance matrix with averaged spike data yielded more robust results across the modalities. MEG was the dominant modality and provided a good localization in one case, while it was EEG for the other. When combining the modalities, the good results of the dominant modality were mostly not spoiled by the weaker modality. For appropriate regularization parameter choices, the beamformer localized better than the standard dipole scan. Compared to the importance of an appropriate regularization, the sensitivity of the localization to the head modelling was smaller, due to similar skull conductivity modelling and the fixed source space without orientation constraint.
format Online
Article
Text
id pubmed-8796031
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-87960312022-01-29 Validating EEG, MEG and Combined MEG and EEG Beamforming for an Estimation of the Epileptogenic Zone in Focal Cortical Dysplasia Neugebauer, Frank Antonakakis, Marios Unnwongse, Kanjana Parpaley, Yaroslav Wellmer, Jörg Rampp, Stefan Wolters, Carsten H. Brain Sci Article MEG and EEG source analysis is frequently used for the presurgical evaluation of pharmacoresistant epilepsy patients. The source localization of the epileptogenic zone depends, among other aspects, on the selected inverse and forward approaches and their respective parameter choices. In this validation study, we compare the standard dipole scanning method with two beamformer approaches for the inverse problem, and we investigate the influence of the covariance estimation method and the strength of regularization on the localization performance for EEG, MEG, and combined EEG and MEG. For forward modelling, we investigate the difference between calibrated six-compartment and standard three-compartment head modelling. In a retrospective study, two patients with focal epilepsy due to focal cortical dysplasia type IIb and seizure freedom following lesionectomy or radiofrequency-guided thermocoagulation (RFTC) used the distance of the localization of interictal epileptic spikes to the resection cavity resp. RFTC lesion as reference for good localization. We found that beamformer localization can be sensitive to the choice of the regularization parameter, which has to be individually optimized. Estimation of the covariance matrix with averaged spike data yielded more robust results across the modalities. MEG was the dominant modality and provided a good localization in one case, while it was EEG for the other. When combining the modalities, the good results of the dominant modality were mostly not spoiled by the weaker modality. For appropriate regularization parameter choices, the beamformer localized better than the standard dipole scan. Compared to the importance of an appropriate regularization, the sensitivity of the localization to the head modelling was smaller, due to similar skull conductivity modelling and the fixed source space without orientation constraint. MDPI 2022-01-14 /pmc/articles/PMC8796031/ /pubmed/35053857 http://dx.doi.org/10.3390/brainsci12010114 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Neugebauer, Frank
Antonakakis, Marios
Unnwongse, Kanjana
Parpaley, Yaroslav
Wellmer, Jörg
Rampp, Stefan
Wolters, Carsten H.
Validating EEG, MEG and Combined MEG and EEG Beamforming for an Estimation of the Epileptogenic Zone in Focal Cortical Dysplasia
title Validating EEG, MEG and Combined MEG and EEG Beamforming for an Estimation of the Epileptogenic Zone in Focal Cortical Dysplasia
title_full Validating EEG, MEG and Combined MEG and EEG Beamforming for an Estimation of the Epileptogenic Zone in Focal Cortical Dysplasia
title_fullStr Validating EEG, MEG and Combined MEG and EEG Beamforming for an Estimation of the Epileptogenic Zone in Focal Cortical Dysplasia
title_full_unstemmed Validating EEG, MEG and Combined MEG and EEG Beamforming for an Estimation of the Epileptogenic Zone in Focal Cortical Dysplasia
title_short Validating EEG, MEG and Combined MEG and EEG Beamforming for an Estimation of the Epileptogenic Zone in Focal Cortical Dysplasia
title_sort validating eeg, meg and combined meg and eeg beamforming for an estimation of the epileptogenic zone in focal cortical dysplasia
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8796031/
https://www.ncbi.nlm.nih.gov/pubmed/35053857
http://dx.doi.org/10.3390/brainsci12010114
work_keys_str_mv AT neugebauerfrank validatingeegmegandcombinedmegandeegbeamformingforanestimationoftheepileptogeniczoneinfocalcorticaldysplasia
AT antonakakismarios validatingeegmegandcombinedmegandeegbeamformingforanestimationoftheepileptogeniczoneinfocalcorticaldysplasia
AT unnwongsekanjana validatingeegmegandcombinedmegandeegbeamformingforanestimationoftheepileptogeniczoneinfocalcorticaldysplasia
AT parpaleyyaroslav validatingeegmegandcombinedmegandeegbeamformingforanestimationoftheepileptogeniczoneinfocalcorticaldysplasia
AT wellmerjorg validatingeegmegandcombinedmegandeegbeamformingforanestimationoftheepileptogeniczoneinfocalcorticaldysplasia
AT ramppstefan validatingeegmegandcombinedmegandeegbeamformingforanestimationoftheepileptogeniczoneinfocalcorticaldysplasia
AT wolterscarstenh validatingeegmegandcombinedmegandeegbeamformingforanestimationoftheepileptogeniczoneinfocalcorticaldysplasia