Cargando…
Review of patient-reported outcomes in periprosthetic distal femur fractures after total knee arthroplasty: a plate or intramedullary nail?
PURPOSE: This study reviewed the literature regarding the patient-reported treatment outcomes of using either open reduction and internal fixation (ORIF) with a plate and screw system or intramedullary nail (IMN) fixation for periprosthetic distal femur fractures around a total knee arthroplasty. ME...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8796545/ https://www.ncbi.nlm.nih.gov/pubmed/35236480 http://dx.doi.org/10.1186/s42836-021-00080-w |
_version_ | 1784641353789997056 |
---|---|
author | Rinehart, Dustin Youngman, Tyler Ahn, Junho Huo, Michael |
author_facet | Rinehart, Dustin Youngman, Tyler Ahn, Junho Huo, Michael |
author_sort | Rinehart, Dustin |
collection | PubMed |
description | PURPOSE: This study reviewed the literature regarding the patient-reported treatment outcomes of using either open reduction and internal fixation (ORIF) with a plate and screw system or intramedullary nail (IMN) fixation for periprosthetic distal femur fractures around a total knee arthroplasty. METHODS: A total of 13 studies published in the last 20 years met the inclusion criteria. The studies included 347 patients who were allocated to ORIF (n = 249) and IMN (n = 98) groups according to the implants used. The primary outcome measures were the Knee Society Score or the Western Ontario and McMaster Universities osteoarthritis index. The secondary outcome measures included knee range of motion and the rates of complications, including non-union, malunion, infection, revision total knee arthroplasty, and reoperation. Statistical significance was set at P < 0.05. RESULTS: The mean Knee Society Scores of ORIF and IMN groups were 83 and 84, respectively; the mean postoperative range of motion of the knee were 99° and 100°, respectively (P < 0.05); the non-union rates were 9.4 and 3.8%, respectively (P > 0.05); the malunion rates were 1.8 and 7.5%, respectively (P < 0.05); surgical site infection rates were 2 and 1.3%, respectively (P > 0.05); the reoperation rates were 9.6 and 5.1%, respectively (P > 0.05); and revision rates of total knee arthroplasty were 2 and 1%, respectively (P > 0.05). CONCLUSION: Based on the patient-reported outcome assessments, both ORIF with a plate and screw system and IMN fixation are well-accepted techniques for periprosthetic distal femur fractures around a TKA, and they produce similar functional outcomes. |
format | Online Article Text |
id | pubmed-8796545 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-87965452022-02-03 Review of patient-reported outcomes in periprosthetic distal femur fractures after total knee arthroplasty: a plate or intramedullary nail? Rinehart, Dustin Youngman, Tyler Ahn, Junho Huo, Michael Arthroplasty Review PURPOSE: This study reviewed the literature regarding the patient-reported treatment outcomes of using either open reduction and internal fixation (ORIF) with a plate and screw system or intramedullary nail (IMN) fixation for periprosthetic distal femur fractures around a total knee arthroplasty. METHODS: A total of 13 studies published in the last 20 years met the inclusion criteria. The studies included 347 patients who were allocated to ORIF (n = 249) and IMN (n = 98) groups according to the implants used. The primary outcome measures were the Knee Society Score or the Western Ontario and McMaster Universities osteoarthritis index. The secondary outcome measures included knee range of motion and the rates of complications, including non-union, malunion, infection, revision total knee arthroplasty, and reoperation. Statistical significance was set at P < 0.05. RESULTS: The mean Knee Society Scores of ORIF and IMN groups were 83 and 84, respectively; the mean postoperative range of motion of the knee were 99° and 100°, respectively (P < 0.05); the non-union rates were 9.4 and 3.8%, respectively (P > 0.05); the malunion rates were 1.8 and 7.5%, respectively (P < 0.05); surgical site infection rates were 2 and 1.3%, respectively (P > 0.05); the reoperation rates were 9.6 and 5.1%, respectively (P > 0.05); and revision rates of total knee arthroplasty were 2 and 1%, respectively (P > 0.05). CONCLUSION: Based on the patient-reported outcome assessments, both ORIF with a plate and screw system and IMN fixation are well-accepted techniques for periprosthetic distal femur fractures around a TKA, and they produce similar functional outcomes. BioMed Central 2021-06-11 /pmc/articles/PMC8796545/ /pubmed/35236480 http://dx.doi.org/10.1186/s42836-021-00080-w Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Review Rinehart, Dustin Youngman, Tyler Ahn, Junho Huo, Michael Review of patient-reported outcomes in periprosthetic distal femur fractures after total knee arthroplasty: a plate or intramedullary nail? |
title | Review of patient-reported outcomes in periprosthetic distal femur fractures after total knee arthroplasty: a plate or intramedullary nail? |
title_full | Review of patient-reported outcomes in periprosthetic distal femur fractures after total knee arthroplasty: a plate or intramedullary nail? |
title_fullStr | Review of patient-reported outcomes in periprosthetic distal femur fractures after total knee arthroplasty: a plate or intramedullary nail? |
title_full_unstemmed | Review of patient-reported outcomes in periprosthetic distal femur fractures after total knee arthroplasty: a plate or intramedullary nail? |
title_short | Review of patient-reported outcomes in periprosthetic distal femur fractures after total knee arthroplasty: a plate or intramedullary nail? |
title_sort | review of patient-reported outcomes in periprosthetic distal femur fractures after total knee arthroplasty: a plate or intramedullary nail? |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8796545/ https://www.ncbi.nlm.nih.gov/pubmed/35236480 http://dx.doi.org/10.1186/s42836-021-00080-w |
work_keys_str_mv | AT rinehartdustin reviewofpatientreportedoutcomesinperiprostheticdistalfemurfracturesaftertotalkneearthroplastyaplateorintramedullarynail AT youngmantyler reviewofpatientreportedoutcomesinperiprostheticdistalfemurfracturesaftertotalkneearthroplastyaplateorintramedullarynail AT ahnjunho reviewofpatientreportedoutcomesinperiprostheticdistalfemurfracturesaftertotalkneearthroplastyaplateorintramedullarynail AT huomichael reviewofpatientreportedoutcomesinperiprostheticdistalfemurfracturesaftertotalkneearthroplastyaplateorintramedullarynail |