Cargando…

Porous-coated metaphyseal sleeves and MBT implant for severe bone loss in revision total knee arthroplasty: a mean 2.4-year follow-up

BACKGROUND: Porous-coated metaphyseal sleeves are designed to fill bone loss and facilitate osseo-integration when bone loss occurs during revision total knee arthroplasty (TKA). The purpose of this paper was to evaluate the clinical and radiographic outcomes of porous-coated metaphyseal sleeves for...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, Yushun, Feng, Eryou, Zhang, Yiyuan, Lin, Feitai, Lin, Liqiong, Li, Zhanglai, Xiao, Lili
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8796563/
https://www.ncbi.nlm.nih.gov/pubmed/35236430
http://dx.doi.org/10.1186/s42836-020-00031-x
_version_ 1784641357851131904
author Wu, Yushun
Feng, Eryou
Zhang, Yiyuan
Lin, Feitai
Lin, Liqiong
Li, Zhanglai
Xiao, Lili
author_facet Wu, Yushun
Feng, Eryou
Zhang, Yiyuan
Lin, Feitai
Lin, Liqiong
Li, Zhanglai
Xiao, Lili
author_sort Wu, Yushun
collection PubMed
description BACKGROUND: Porous-coated metaphyseal sleeves are designed to fill bone loss and facilitate osseo-integration when bone loss occurs during revision total knee arthroplasty (TKA). The purpose of this paper was to evaluate the clinical and radiographic outcomes of porous-coated metaphyseal sleeves for severe bone loss in revision TKA. METHODS: Form December 2014 to March 2018, we retrospectively analyzed 36 patients receiving revision TKAs. They had Anderson Orthopaedic Research Institute (AORI) Type II and III tibial bone loss and were treated with metaphyseal sleeve. The patients were followed up for a mean time of 28.5 months. The Knee Society Score (KSS), the Hospital for Special Surgery (HSS) Knee Score, Visual Analog Scale (VAS) score and the range of motion (ROM), radiographic findings of sleeve osteo-integration were also recorded. The paired t test was used to compare the KSS, the HSS knee score and VAS score before and after the revision TKAs. A value of P < 0.05 was considered statistically significant. RESULTS: Thirty-six patients had complete clinical and radiographic data. At the final follow-up (mean: 28.5 months), significant improvements in knee range of motion, KSS, HSS score and VAS score were observed postoperatively (P < 0.001 for all). No aseptic implant fixation failure occurred. Radiographic reviews at the final follow-up revealed that components were stable without occurrence of component migration or clinically significant osteolysis. CONCLUSIONS: This short-term retrospective study illustrated that porous-coated metaphyseal sleeves were useful in revision TKA, with a low rate of intraoperative complications, excellent osteo-integration and stable fixation.
format Online
Article
Text
id pubmed-8796563
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-87965632022-02-03 Porous-coated metaphyseal sleeves and MBT implant for severe bone loss in revision total knee arthroplasty: a mean 2.4-year follow-up Wu, Yushun Feng, Eryou Zhang, Yiyuan Lin, Feitai Lin, Liqiong Li, Zhanglai Xiao, Lili Arthroplasty Research BACKGROUND: Porous-coated metaphyseal sleeves are designed to fill bone loss and facilitate osseo-integration when bone loss occurs during revision total knee arthroplasty (TKA). The purpose of this paper was to evaluate the clinical and radiographic outcomes of porous-coated metaphyseal sleeves for severe bone loss in revision TKA. METHODS: Form December 2014 to March 2018, we retrospectively analyzed 36 patients receiving revision TKAs. They had Anderson Orthopaedic Research Institute (AORI) Type II and III tibial bone loss and were treated with metaphyseal sleeve. The patients were followed up for a mean time of 28.5 months. The Knee Society Score (KSS), the Hospital for Special Surgery (HSS) Knee Score, Visual Analog Scale (VAS) score and the range of motion (ROM), radiographic findings of sleeve osteo-integration were also recorded. The paired t test was used to compare the KSS, the HSS knee score and VAS score before and after the revision TKAs. A value of P < 0.05 was considered statistically significant. RESULTS: Thirty-six patients had complete clinical and radiographic data. At the final follow-up (mean: 28.5 months), significant improvements in knee range of motion, KSS, HSS score and VAS score were observed postoperatively (P < 0.001 for all). No aseptic implant fixation failure occurred. Radiographic reviews at the final follow-up revealed that components were stable without occurrence of component migration or clinically significant osteolysis. CONCLUSIONS: This short-term retrospective study illustrated that porous-coated metaphyseal sleeves were useful in revision TKA, with a low rate of intraoperative complications, excellent osteo-integration and stable fixation. BioMed Central 2020-04-20 /pmc/articles/PMC8796563/ /pubmed/35236430 http://dx.doi.org/10.1186/s42836-020-00031-x Text en © The Author(s) 2020 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Research
Wu, Yushun
Feng, Eryou
Zhang, Yiyuan
Lin, Feitai
Lin, Liqiong
Li, Zhanglai
Xiao, Lili
Porous-coated metaphyseal sleeves and MBT implant for severe bone loss in revision total knee arthroplasty: a mean 2.4-year follow-up
title Porous-coated metaphyseal sleeves and MBT implant for severe bone loss in revision total knee arthroplasty: a mean 2.4-year follow-up
title_full Porous-coated metaphyseal sleeves and MBT implant for severe bone loss in revision total knee arthroplasty: a mean 2.4-year follow-up
title_fullStr Porous-coated metaphyseal sleeves and MBT implant for severe bone loss in revision total knee arthroplasty: a mean 2.4-year follow-up
title_full_unstemmed Porous-coated metaphyseal sleeves and MBT implant for severe bone loss in revision total knee arthroplasty: a mean 2.4-year follow-up
title_short Porous-coated metaphyseal sleeves and MBT implant for severe bone loss in revision total knee arthroplasty: a mean 2.4-year follow-up
title_sort porous-coated metaphyseal sleeves and mbt implant for severe bone loss in revision total knee arthroplasty: a mean 2.4-year follow-up
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8796563/
https://www.ncbi.nlm.nih.gov/pubmed/35236430
http://dx.doi.org/10.1186/s42836-020-00031-x
work_keys_str_mv AT wuyushun porouscoatedmetaphysealsleevesandmbtimplantforseverebonelossinrevisiontotalkneearthroplastyamean24yearfollowup
AT fengeryou porouscoatedmetaphysealsleevesandmbtimplantforseverebonelossinrevisiontotalkneearthroplastyamean24yearfollowup
AT zhangyiyuan porouscoatedmetaphysealsleevesandmbtimplantforseverebonelossinrevisiontotalkneearthroplastyamean24yearfollowup
AT linfeitai porouscoatedmetaphysealsleevesandmbtimplantforseverebonelossinrevisiontotalkneearthroplastyamean24yearfollowup
AT linliqiong porouscoatedmetaphysealsleevesandmbtimplantforseverebonelossinrevisiontotalkneearthroplastyamean24yearfollowup
AT lizhanglai porouscoatedmetaphysealsleevesandmbtimplantforseverebonelossinrevisiontotalkneearthroplastyamean24yearfollowup
AT xiaolili porouscoatedmetaphysealsleevesandmbtimplantforseverebonelossinrevisiontotalkneearthroplastyamean24yearfollowup