Evaluation of mechanical properties of platelet-rich fibrin membrane for implant surgery: An analysis in vitro
The aim of this study was to evaluate and compare the mechanical resistance of platelet-rich fibrin (PRF) membrane when submitted to resistance traction on longitudinal axis. Blood collection of a healthy individual was collected with an amount of 300 mL and divided into 30 tubes containing 10 mL ea...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8796778/ https://www.ncbi.nlm.nih.gov/pubmed/35136312 http://dx.doi.org/10.4103/jisp.jisp_782_20 |
_version_ | 1784641401904955392 |
---|---|
author | Petronilho, Vinicius Gustavo de Fátima Balderrama, Ísis de Oliveira, Leonel Alves Queiroz, Polyane Mazucatto Zubek, Marcos Giovanetti Gottardo, Vilmar Divanir |
author_facet | Petronilho, Vinicius Gustavo de Fátima Balderrama, Ísis de Oliveira, Leonel Alves Queiroz, Polyane Mazucatto Zubek, Marcos Giovanetti Gottardo, Vilmar Divanir |
author_sort | Petronilho, Vinicius Gustavo |
collection | PubMed |
description | The aim of this study was to evaluate and compare the mechanical resistance of platelet-rich fibrin (PRF) membrane when submitted to resistance traction on longitudinal axis. Blood collection of a healthy individual was collected with an amount of 300 mL and divided into 30 tubes containing 10 mL each one. The samples were divided into three groups, according to the g-force protocols: (1) F200 g: (2) F400 g; (3) F800 g. Membranes of each g-force group were divided into subgroups, according to waiting time after centrifugation: (T0) immediate use and (T30) use after 30 min. Considering these intervals of time, the concentrate was removed from tubes and inserted in a PRF metallic box to confection of the membrane. The PRF membranes were submitted to mechanical tension on a universal testing machine and obtained to a resistance force of each membrane. The centrifugation time showed no statistically significant difference for membrane resistance for any force applied (P > 0.05; Student's t-test). For T0 group results demonstrated no influence for membrane resistance (P = 0.357; Student's t-test), therefore T30 showed statistically significant difference (P = 0.040; Student's t-test) for membrane resistance for centrifugation forces applied, with highest value when applied greatest force. The findings suggest that the waiting time for centrifugation could be determined according to demand of application, and for immediate use of the membrane, the centrifugation did not influence the resistance, on the other hand, after 30 min, the application of higher force resulted in a membrane with considerable resistance. |
format | Online Article Text |
id | pubmed-8796778 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-87967782022-02-07 Evaluation of mechanical properties of platelet-rich fibrin membrane for implant surgery: An analysis in vitro Petronilho, Vinicius Gustavo de Fátima Balderrama, Ísis de Oliveira, Leonel Alves Queiroz, Polyane Mazucatto Zubek, Marcos Giovanetti Gottardo, Vilmar Divanir J Indian Soc Periodontol Original Article The aim of this study was to evaluate and compare the mechanical resistance of platelet-rich fibrin (PRF) membrane when submitted to resistance traction on longitudinal axis. Blood collection of a healthy individual was collected with an amount of 300 mL and divided into 30 tubes containing 10 mL each one. The samples were divided into three groups, according to the g-force protocols: (1) F200 g: (2) F400 g; (3) F800 g. Membranes of each g-force group were divided into subgroups, according to waiting time after centrifugation: (T0) immediate use and (T30) use after 30 min. Considering these intervals of time, the concentrate was removed from tubes and inserted in a PRF metallic box to confection of the membrane. The PRF membranes were submitted to mechanical tension on a universal testing machine and obtained to a resistance force of each membrane. The centrifugation time showed no statistically significant difference for membrane resistance for any force applied (P > 0.05; Student's t-test). For T0 group results demonstrated no influence for membrane resistance (P = 0.357; Student's t-test), therefore T30 showed statistically significant difference (P = 0.040; Student's t-test) for membrane resistance for centrifugation forces applied, with highest value when applied greatest force. The findings suggest that the waiting time for centrifugation could be determined according to demand of application, and for immediate use of the membrane, the centrifugation did not influence the resistance, on the other hand, after 30 min, the application of higher force resulted in a membrane with considerable resistance. Wolters Kluwer - Medknow 2022 2022-01-01 /pmc/articles/PMC8796778/ /pubmed/35136312 http://dx.doi.org/10.4103/jisp.jisp_782_20 Text en Copyright: © 2022 Indian Society of Periodontology https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Petronilho, Vinicius Gustavo de Fátima Balderrama, Ísis de Oliveira, Leonel Alves Queiroz, Polyane Mazucatto Zubek, Marcos Giovanetti Gottardo, Vilmar Divanir Evaluation of mechanical properties of platelet-rich fibrin membrane for implant surgery: An analysis in vitro |
title | Evaluation of mechanical properties of platelet-rich fibrin membrane for implant surgery: An analysis in vitro |
title_full | Evaluation of mechanical properties of platelet-rich fibrin membrane for implant surgery: An analysis in vitro |
title_fullStr | Evaluation of mechanical properties of platelet-rich fibrin membrane for implant surgery: An analysis in vitro |
title_full_unstemmed | Evaluation of mechanical properties of platelet-rich fibrin membrane for implant surgery: An analysis in vitro |
title_short | Evaluation of mechanical properties of platelet-rich fibrin membrane for implant surgery: An analysis in vitro |
title_sort | evaluation of mechanical properties of platelet-rich fibrin membrane for implant surgery: an analysis in vitro |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8796778/ https://www.ncbi.nlm.nih.gov/pubmed/35136312 http://dx.doi.org/10.4103/jisp.jisp_782_20 |
work_keys_str_mv | AT petronilhoviniciusgustavo evaluationofmechanicalpropertiesofplateletrichfibrinmembraneforimplantsurgeryananalysisinvitro AT defatimabalderramaisis evaluationofmechanicalpropertiesofplateletrichfibrinmembraneforimplantsurgeryananalysisinvitro AT deoliveiraleonelalves evaluationofmechanicalpropertiesofplateletrichfibrinmembraneforimplantsurgeryananalysisinvitro AT queirozpolyanemazucatto evaluationofmechanicalpropertiesofplateletrichfibrinmembraneforimplantsurgeryananalysisinvitro AT zubekmarcosgiovanetti evaluationofmechanicalpropertiesofplateletrichfibrinmembraneforimplantsurgeryananalysisinvitro AT gottardovilmardivanir evaluationofmechanicalpropertiesofplateletrichfibrinmembraneforimplantsurgeryananalysisinvitro |