Cargando…

Evaluation of mechanical properties of platelet-rich fibrin membrane for implant surgery: An analysis in vitro

The aim of this study was to evaluate and compare the mechanical resistance of platelet-rich fibrin (PRF) membrane when submitted to resistance traction on longitudinal axis. Blood collection of a healthy individual was collected with an amount of 300 mL and divided into 30 tubes containing 10 mL ea...

Descripción completa

Detalles Bibliográficos
Autores principales: Petronilho, Vinicius Gustavo, de Fátima Balderrama, Ísis, de Oliveira, Leonel Alves, Queiroz, Polyane Mazucatto, Zubek, Marcos Giovanetti, Gottardo, Vilmar Divanir
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8796778/
https://www.ncbi.nlm.nih.gov/pubmed/35136312
http://dx.doi.org/10.4103/jisp.jisp_782_20
_version_ 1784641401904955392
author Petronilho, Vinicius Gustavo
de Fátima Balderrama, Ísis
de Oliveira, Leonel Alves
Queiroz, Polyane Mazucatto
Zubek, Marcos Giovanetti
Gottardo, Vilmar Divanir
author_facet Petronilho, Vinicius Gustavo
de Fátima Balderrama, Ísis
de Oliveira, Leonel Alves
Queiroz, Polyane Mazucatto
Zubek, Marcos Giovanetti
Gottardo, Vilmar Divanir
author_sort Petronilho, Vinicius Gustavo
collection PubMed
description The aim of this study was to evaluate and compare the mechanical resistance of platelet-rich fibrin (PRF) membrane when submitted to resistance traction on longitudinal axis. Blood collection of a healthy individual was collected with an amount of 300 mL and divided into 30 tubes containing 10 mL each one. The samples were divided into three groups, according to the g-force protocols: (1) F200 g: (2) F400 g; (3) F800 g. Membranes of each g-force group were divided into subgroups, according to waiting time after centrifugation: (T0) immediate use and (T30) use after 30 min. Considering these intervals of time, the concentrate was removed from tubes and inserted in a PRF metallic box to confection of the membrane. The PRF membranes were submitted to mechanical tension on a universal testing machine and obtained to a resistance force of each membrane. The centrifugation time showed no statistically significant difference for membrane resistance for any force applied (P > 0.05; Student's t-test). For T0 group results demonstrated no influence for membrane resistance (P = 0.357; Student's t-test), therefore T30 showed statistically significant difference (P = 0.040; Student's t-test) for membrane resistance for centrifugation forces applied, with highest value when applied greatest force. The findings suggest that the waiting time for centrifugation could be determined according to demand of application, and for immediate use of the membrane, the centrifugation did not influence the resistance, on the other hand, after 30 min, the application of higher force resulted in a membrane with considerable resistance.
format Online
Article
Text
id pubmed-8796778
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-87967782022-02-07 Evaluation of mechanical properties of platelet-rich fibrin membrane for implant surgery: An analysis in vitro Petronilho, Vinicius Gustavo de Fátima Balderrama, Ísis de Oliveira, Leonel Alves Queiroz, Polyane Mazucatto Zubek, Marcos Giovanetti Gottardo, Vilmar Divanir J Indian Soc Periodontol Original Article The aim of this study was to evaluate and compare the mechanical resistance of platelet-rich fibrin (PRF) membrane when submitted to resistance traction on longitudinal axis. Blood collection of a healthy individual was collected with an amount of 300 mL and divided into 30 tubes containing 10 mL each one. The samples were divided into three groups, according to the g-force protocols: (1) F200 g: (2) F400 g; (3) F800 g. Membranes of each g-force group were divided into subgroups, according to waiting time after centrifugation: (T0) immediate use and (T30) use after 30 min. Considering these intervals of time, the concentrate was removed from tubes and inserted in a PRF metallic box to confection of the membrane. The PRF membranes were submitted to mechanical tension on a universal testing machine and obtained to a resistance force of each membrane. The centrifugation time showed no statistically significant difference for membrane resistance for any force applied (P > 0.05; Student's t-test). For T0 group results demonstrated no influence for membrane resistance (P = 0.357; Student's t-test), therefore T30 showed statistically significant difference (P = 0.040; Student's t-test) for membrane resistance for centrifugation forces applied, with highest value when applied greatest force. The findings suggest that the waiting time for centrifugation could be determined according to demand of application, and for immediate use of the membrane, the centrifugation did not influence the resistance, on the other hand, after 30 min, the application of higher force resulted in a membrane with considerable resistance. Wolters Kluwer - Medknow 2022 2022-01-01 /pmc/articles/PMC8796778/ /pubmed/35136312 http://dx.doi.org/10.4103/jisp.jisp_782_20 Text en Copyright: © 2022 Indian Society of Periodontology https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Petronilho, Vinicius Gustavo
de Fátima Balderrama, Ísis
de Oliveira, Leonel Alves
Queiroz, Polyane Mazucatto
Zubek, Marcos Giovanetti
Gottardo, Vilmar Divanir
Evaluation of mechanical properties of platelet-rich fibrin membrane for implant surgery: An analysis in vitro
title Evaluation of mechanical properties of platelet-rich fibrin membrane for implant surgery: An analysis in vitro
title_full Evaluation of mechanical properties of platelet-rich fibrin membrane for implant surgery: An analysis in vitro
title_fullStr Evaluation of mechanical properties of platelet-rich fibrin membrane for implant surgery: An analysis in vitro
title_full_unstemmed Evaluation of mechanical properties of platelet-rich fibrin membrane for implant surgery: An analysis in vitro
title_short Evaluation of mechanical properties of platelet-rich fibrin membrane for implant surgery: An analysis in vitro
title_sort evaluation of mechanical properties of platelet-rich fibrin membrane for implant surgery: an analysis in vitro
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8796778/
https://www.ncbi.nlm.nih.gov/pubmed/35136312
http://dx.doi.org/10.4103/jisp.jisp_782_20
work_keys_str_mv AT petronilhoviniciusgustavo evaluationofmechanicalpropertiesofplateletrichfibrinmembraneforimplantsurgeryananalysisinvitro
AT defatimabalderramaisis evaluationofmechanicalpropertiesofplateletrichfibrinmembraneforimplantsurgeryananalysisinvitro
AT deoliveiraleonelalves evaluationofmechanicalpropertiesofplateletrichfibrinmembraneforimplantsurgeryananalysisinvitro
AT queirozpolyanemazucatto evaluationofmechanicalpropertiesofplateletrichfibrinmembraneforimplantsurgeryananalysisinvitro
AT zubekmarcosgiovanetti evaluationofmechanicalpropertiesofplateletrichfibrinmembraneforimplantsurgeryananalysisinvitro
AT gottardovilmardivanir evaluationofmechanicalpropertiesofplateletrichfibrinmembraneforimplantsurgeryananalysisinvitro