Dosimetric evaluation of helical tomotherapy and volumetric-modulated arc therapy for malignant pleural mesothelioma: a planning study for dose escalation

BACKGROUND: To compare the dosimetric differences between helical tomotherapy (HT) and volumetric-modulated arc therapy (VMAT) treatment plans for inoperable malignant pleural mesothelioma (MPM). METHODS: Ten patients with inoperable MPM were retrospectively planned with the HT and VMAT techniques,...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Fu-Li, Lu, Na, Jiang, Hua-Yong, Chen, Dian-Dian, Wang, Ya-Di
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8798385/
https://www.ncbi.nlm.nih.gov/pubmed/35116420
http://dx.doi.org/10.21037/tcr-20-2452
Descripción
Sumario:BACKGROUND: To compare the dosimetric differences between helical tomotherapy (HT) and volumetric-modulated arc therapy (VMAT) treatment plans for inoperable malignant pleural mesothelioma (MPM). METHODS: Ten patients with inoperable MPM were retrospectively planned with the HT and VMAT techniques, and the dose-volume histogram (DVH)-based parameters of the planning target volume (PTV) and organs at risk (OARs) were compared. RESULTS: Compared with the VMAT plans, the target homogeneity index (HI) and conformity index (CI) of the HT plans were significantly better (HI: 1.04±0.01 vs. 1.11±0.03, CI: 0.80±0.07 vs. 0.71±0.12, respectively) (P<0.001, P=0.013, respectively). Regarding the OARs, including the ipsilateral lung, contralateral lung, heart, and spinal cord, the differences among the V30 (Vx: fraction of volume receiving >5, 10, 20, and 30 Gy, respectively) of the ipsilateral lung and V5, V10, and V20 of the contralateral lung were statistically significant (P=0.031, P=0.030, P=0.021, P=0.003, respectively). However, there was no significant differences between HT plans and VMAT plans, regarding the V5, V10 and V20 of the ipsilateral lung, V3 of the contralateral lung, V5 and Dmean of the heart, and Dmax of the cord. The treatment delivery time of the VMAT was significantly shorter than that of the HT (mean delivery time: 3.27±1.65 vs. 11.11±3.75 min, respectively) (P<0.001). CONCLUSIONS: Compared to the VMAT plans, the HT plans not only demonstrated more optimal target coverage and conformity but also considerably reduced the dose-volume parameters of the OARs in both low-dose areas in contralateral lung and high-dose areas in ipsilateral lung and contralateral lung, which is correlated to radiation injury. However, the treatment delivery time of the HT plans was longer.